Loading...
HomeMy WebLinkAboutR-406926Vl Q0 0 11 0 n� W R[F=(D:0R[0 BH/R�V�Ha CALL 2 BUSINESS DAYS BEFORE YOU DIG 1 800 424 - 5555 UTILITIES UNDERGROUND LOCATION CENTER ABBREVIATIONS AFF ABOVE FINISHED FLOOR MAX MAXIMUN APPROX APPROXIMATE MECH MECHANICAL ARCH ARCHITECTURAL MEZZ MEZZANINE MFR MANUFACTURE BLDG BUILDING MIN MINIMUM, MINUTE BLKG BLOCKING MISC MISCELLANEOUS BO BOTTOM OF MTL METAL CJ CONTRO JOINT N NORTH CL CENTERLINE NIC NOT IN CONTRACT CLR CLEAR NO NUMBER COL COLUMN NTS NOT TO SCALE CONC CONCRETE CONT CONTINUOUS, CONTINUE OC ON CENTER OH OVERHEAD D DEEP, DEPTH OD OUTSIDE DIAMETER DEMO DEMOLISH, DEMOLITION OPNG OPENING DTL DETAIL OPP OPPOSITE DIA DIAMETER ORD OVERFLOW ROOF DRAIN DIM DIMENSION ORD OVERFLOW ROOF DRAIN DN DOWN DS DOWNSPOUT PERP PERPENDICULAR DWG DRAWING PLYWD PLYWOOD PL PROPERTY LINE E EAST PR PAIR (E), EXIST EXISTING PT PAINT, POINT, PRESSURE TREATED EJ EXPANSION JOINT EL ELEVATION R RADIUS, RISER ELEC ELECTRIC, ELECTRICAL RD ROOF DRAIN, ROAD EQ EQUAL REINF REINFORCED, REINFORCING EQUIP EQUIPMENT REQD REQUIRED REV REVISED, REVISION FCIO FURNISHED BY CONTRACTOR/ RM ROOM INSTALLED BY OWNER RO ROUGH OPENING FIN FINISH, FINISHED FO FACE OF S SOUTH FOIC FURNISHED BY OWNER/ SHT SHEET INSTALLED BY CONTRACTOR SHTHG SHEATHING FT FOOT, FEET SIM SIMILAR SPEC SPECIFICATION GA GAGE,GAUGE SQ SQUARE GALV GALVANIZED SS STAINLESS STEEL GWB GYPSUM WALL BOARD STL STEEL GYP BD GYPSUM BOARD STOR STORAGE STRUCT STRUCTURAL H HIGH SUSP SUSPENDED HORIZ HORIZONTAL HR HOUR T&G TONGUE AND GROOVE HT HEIGHT TO TOP OF HVAC HEATING, VENTILATING, TYP TYPICAL AND AIR CONDITIONING UON UNLESS OTHERWISE NOTED ID INSIDE DIAMETER INSUL INSULATE, INSULATION VERT VERTICAL L LONG W WEST, WIDE W/ WITH W/O WITHOUT WD WOOD WRB WATER -RESISTIVE VAPOR PERMEABLE SELF -ADHERED AIR BARRIER PROJECT INFORMATION JURISDICTION: CITY OF RENTON APPLICABLE CODES: 2015 IBC, IMC, IFC, IECC, UPC, AND WSEC CONSTRUCTION TYPE: V OCCUPATION TYPE: B BUILDING AREA: TRELLIS: 470 SF (EACH) GAZEBO: 1,150 SF rolluda architects architecture planning interior design ROLLUDA ARCHITECTS INC. 105 SOUTH MAIN STREET, SUITE 323 SEATTLE, WASHINGTON 98104 6250 REGISTERED ARCHITECT Alex E. Rolluda STATE OF WASHINGTON GENERAL NOTES 1. DRAWINGS. THE DRAWINGS ARE INTENDED TO DESCRIBE THE OVERALL SCOPE OF WORK. CONTRACTORS SHALL FIELD VERIFY EXISTING CONDITIONS AND ALERT THE ARCHITECT TO ANY CONFLICTS BEFORE BEGINNING WORK. 2. (E) OR'EXIST.' INDICATES EXISTING CONDITION, DIMENSION OR DATUM. VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS ON PROJECT PRIOR TO COMMENCEMENT OF WORK. 3. DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL USE DIMENSIONS SHOWN ON THE DRAWINGS AND ACTUAL FIELD MEASUREMENTS. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES WITH DRAWINGS. 4. CONTRACTOR TO VERIFY ALL DIMENSIONS, PROPERTY LINES, MEASUREMENTS AND CONDITIONS IN THE FIELD BEFORE BEGINNING WORK. ANY DISCREPANCIES, ERRORS OR OMISSIONS TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY. 5. TYPICAL WALL SECTIONS, FINISHES, AND DETAILS ARE NOT INDICATED EVERYWHERE THEY OCCUR ON PLANS, ELEVATIONS, AND SECTIONS. REFER TO DETAILED DRAWINGS. CONTRACTOR TO PROVIDE AS IF DRAWN IN FULL. 6. DETAILED AND/OR LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER GENERAL AND SMALLER SCALE DRAWINGS. 7. GENERALLY PLAN DIMENSIONS SHOWN ARE TO FINISH OPENING, FACE OF CONCRETE SHEATHING, OR FACE OF STUD UNLESS NOTED OTHERWISE. 8. UNLESS OTHERWISE NOTED, ALL ANGLES TO BE RIGHT ANGLES, ALL LINES WHICH APPEAR PARALLEL ARE TO BE PARALLEL, AND ALL ITEMS WHICH APPEAR CENTERED ARE TO BE CENTERED. CONTRACTOR TO BE RESPONSIBLE FOR MAINTAINING ALL LINES TRUE, LEVEL, PLUMB, AND SQUARE. 9. NOTHING IN THE DRAWINGS SHALL BE CONSTRUED TO PERMIT AN INSTALLATION IN VIOLATION OF APPLICABLE CODES. ALL WORK PERFORMED UNDER THIS CONTRACT SHALL BE IN FULL ACCORDANCE WITH THE LATEST RULES, REGULATIONS, RESTRICTIONS, REQUIREMENTS, AND CODES OF THE GOVERNING JURISDICTIONS. 10. THE CONTRACTOR SHALL VERIFY ALL ROUGH -IN DIMENSIONS FOR THE EQUIPMENT. 11. ALL ATTACHMENTS, CONNECTIONS, AND FASTENINGS OF ANY NATURE ARE TO BE PROPERLY AND PERMANENTLY SECURED IN CONFORMANCE WITH THE BEST PRACTICES OF THE BUILDING INDUSTRY. DRAWINGS SHOW ONLY SPECIAL REQUIREMENTS TO ASSIST THE CONTRACTOR AND DO NOT SHOW EVERY DETAIL. 12. CAULKING AND SEALANTS. USE PRIMERS AS REQUIRED BY MANUFACTURER. BACKING RODS OR TAPE AS RECOMMENDED BY MANUFACTURER AND PER SPECIFICATIONS. 13. VAPOR BARRIERS. CONTINUOUS AND APPROVED VAPOR BARRIERS SHALL BE INSTALLED ON THE HEATED SIDE OF ALL THERMAL INSULATION INSTALLED AS INDICATED. SEAL ALL EDGES. 14. CONTRACTOR AT BEGINNING OF WORK TO FLUSH ALL ROOF DRAINS TO CONFIRM IN WORKING ORDER. AT CONCLUSION OF WORK CONTRACTOR TO TEST ALL ROOF DRAINS TO CONFIRM IN WORKING ORDER AND TIGHT LINES THROUGHOUT BUILDING AND PROVIDE CONFIRMATION REPORT TO OWNER. 15. CONTRACTOR SHALL VERIFY LOCATION OF ALL EXISTING UTILITIES AND PROTECT AS REQUIRED PRIOR TO COMMENCEMENT OF WORK. 16. CONTRACTOR TO COORDINATE ALL OPERATIONS WITH OWNER, INCLUDING: SITE ACCESS, MATERIALS STORAGE, AND STAGING, INTERRUPTION OF ELECTRICAL AND MECHANICAL SERVICES AND TIMING OF NOISY AND DISRUPTIVE OPERATIONS. CONTRACTOR TO VERIFY SEQUENCE OF WORK WITH OWNER. 17. CONTRACTOR SHALL COORDINATE WITH FACILITIES FOR REMOVAL OF ROOFTOP MOUNTED EQUIPMENT AS NEEDED FOR CURB AND FLASHING INSTALLATION, AND RE- ROOFING. 18. CONTRACTOR TO PROTECT EXISTING FURNISHINGS, FIXTURES, EQUIPMENT AND LANDSCAPING FROM DAMAGE. CONTRACTOR TO REPLACE IN KIND ANY SUCH ITEMS DAMAGED. 19. CONTRACTOR SHALL PROTECT ALL ROOF OPENINGS FROM WATER PENETRATION DURING CONSTRUCTION. 20. CONTRACTOR SHALL MAINTAIN CURRENT RECORD DRAWINGS FOR ARCHITECT'S PERIODIC REVIEW. 21. AS BUILT DRAWINGS ARE BASED ON RECORD DRAWINGS AND MAY BE INCLUDED FOR REFERENCE AS TO THE SCOPE OF WORK ONLY. CONTRACTOR SHALL VISIT SITE PRIOR TO BID, EXAMINE EXISTING CONDITIONS AND INCLUDE ALL DEMOLITION REQUIREMENTS FOR THE SCOPE OF THE PROJECT IN THE CONTRACT SUM. NO ADDITIONAL PAYMENTS WILL BE MADE FOR FAILURE TO OBTAIN ALL REQUIRED INFORMATION AND MAKE KNOWN ANY INACCURACIES. ONTRACTOR AS BUILTS PROVIDED RY TERRADYNAMICS ldc 04/07/�) 1 bUKVty­ RECORD DRAWINGS 1 104/16/2 DESIGNED: HIS RECORD DRAWING HAS BEEN PREPARED BASED ON INFORMATION SUBMITTED, IN PART, B ROLLUDAARCHITECTS HE CONTRACTOR. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, IT HAS NOT BEEN DRAWN: URVEYED OR VERIFIED FOR COMPLETENESS, AND THE LANDSCAPE ARCHITECT, ARCHITECT, OR M. MANCERA NGINEER IS NOT RESPONSIBLE FOR ITS ACCURACY, NOR FOR ERRORS OR OMMISSIONS WHICF CHECKED IAY HAVE BEEN INCORPORATED INTO THE RECORD DRAWINGS AS A RESULT. R. MURAKAMI APPROVED: NO. REVISION BY DATE APPR R. MURAKAMI SCALE: VERTICAL: NAVD 1988 AS HORIZONTAL: NAD 198311991 NOTED ONE INCH DATU M AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY CITY OF RENTON Community Services Dept. DRAWING INDEX ARCHITECTURAL SHEET NUMBER SHEET NAME A-000 TG PLAN A-OOX ARCHITECTURAL GENERAL NOTES A-100 OVERALL SITE PLAN A-101 PERGOLA FLOOR PLAN, ELEVATION AND DETAILS A-102 GAZEBO FLOOR AND GUARDRAIL PLANS A-103 GAZEBO RCP AND ROOF PLANS A-104 GAZEBO FRAME SECTIONS A-105 GAZEBO COLUMN ELEVATIONS A-106 GAZEBO ROOF AND COLUMN DETAILS A-107 GAZEBO GUARDRAIL DETAILS A-108 GAZEBO TRENCH DETAILS A-109 RESTROOM EXISTING RCP PLAN AND DETAIL A-110 GAZEBO ELEVATIONS REFERENCE SYMBOLS x x AX.X AX.XX BUILDING SECTION INDICATOR x Ax. SECTION INDICATOR xx Ax. SECTION DETAIL INDICATOR ENLARGED DETAIL INDICATOR X.X (X.X COLUMN GRIDLINE INDICATOR X.X FLAGNOTE Ax DRAWING REVISION INDICATOR XX'-XX" xxxxxxx ELEVATOR INDICATOR MATCH LINE O SEE SHEET AX.XX SUNSET NEIGHBORHOOD PARK PHASE 2 ARCHITECTURAL GENERAL NOTES R-406926 DAT E: 11 /25/2019 FIELDBOOK: PAGE: DRAWING NO: A-001 SHEET: OF' 26 77 0 N 0, 0 0) u