Loading...
HomeMy WebLinkAboutR-406974VI 0 0 1. 0 n� LJ Ld IRRIGATION SCHEDULE POP-UP HEAD W/ TRIPLE SWING JOINT RISER SYMBOL MANUFACTURER/MODEL ARC PSI GPM+10% RADIUS/ WxL ® RAINBIRD 1812-SAM-PRS30-MPR-5Q 90 30 0.11 5' ® RAINBIRD 1812-SAM-PRS30-MPR-5H 90 30 0.22 5' ® RAINBIRD 1812-SAM-PRS30-U8F 360 30 1.16 8' ® RAINBIRD 1812-SAM-PRS30-U8H 180 30 0.57 8' ® RAINBIRD 1812-SAM-PRS30-U8Q 90 30 0.29 8' C RAINBIRD 1812-SAM-PRS30-U 1 OF 360 30 1.80 10' RAINBIRD 1812-SAM-PRS30-U 1 OH 180 30 0.90 10' RAINBIRD 1812-SAM-PRS30-U 1 OQ 90 30 0.45 10' O RAINBIRD 1812-SAM-PRS30-U 12F 360 30 2.86 12' RAINBIRD 1812-SAM-PRS30-U 12H 180 30 1.43 12' RAINBIRD 1812-SAM-PRS30-U 12Q 90 30 0.72 12' O RAINBIRD 1812-SAM-PRS30-U 15F 360 30 4.07 15' 0 RAINBIRD 1812-SAM-PRS30-U 15H 180 30 2.04 15' RAINBIRD 1812-SAM-PRS30-U 15Q 90 30 1.01 15' RAINBIRD 1812-SAM-PRS30-M PR- 15RCS 30 0.54 4' x 15' 0 RAINBIRD 1812-SAM-PRS30-M PR- 15LCS 30 0.54 4' x 15' 0 RAINBIRD 1812-SAM-PRS30-M PR- 15SST 30 1.33 4' x 30' 0 RAINBIRD 1806-SAM-PRS30-HE-VAN15 90 30 1.02 15' 0 RAINBIRD 1806-SAM-PRS30-HE-VAN15 180 30 2.04 15' RAINBIRD 1806-SAM-PRS30-HE -VAN 15 45-270 30 0.56-3.06 15' RAINBIRD F4-FC-6 360 50 6.05 49' Ilk RAINBIRD F4-PC-6 180 50 6.05 49' RAINBIRD FC-PC-6 90 50 6.05 49' RAINBIRD FC-PC-4 * 180 50 4.07 34' I" RAINBIRD FC-PC-4 * 90 50 4.07 34' * REDUCE RADIUS AT HEAD BY 15% ALL SPRAY NOZZLES IN TURF TO BE INSTALLED ON 4" POP-UP HEADS. ALL SPRAY NOZZLES INSTALLED IN SHRUB AND GROUNDCOVER PLANTING AREAS TO BE INSTALLED ON 12" POP-UP SPRAY HEADS. IRRIGATION ABBREVIATIONS PERCENT GPM GALLONS PER MINUTE PSI & AND IRR IRRIGATION REP @ AT L LENGTH S #/NO NUMBER MAX MAXIMUM SCH ABBV ABBREVIATIONS MECH MECHANICAL SPEC(S) ARCH ARCHITECTURAL MFRS MANUFACTURERS STD q_ CENTER LINE MIN MINIMUM T COR CITY OF RENTON OC ON CENTER TYP DIA DIAMETER OD OUTSIDE DIAMETER W DWGS DRAWINGS POC POINT OF CONNECTION W/ EX EXISTING PVC POLYVINYL CHLORIDE nIE(MMID lonlm�H(K_� IRRIGATION LEGEND 27 2 L-27 J24 J27 J24 J27 QYKAPr) I FAJ, DESCRIPTION PIPE SLEEVES (SCH 40 PVC) LATERAL LINE WITH SIZE (CLASS 200 PVC), SEE PIPE SIZE LEGEND 2Y2" MAINLINE (SCH 40 PVC) 1" QUICK COUPLING VALVE W/ KEY & HOSE SWIVEL RAINBIRD 44-LRC © IRRIGATION CONTROLLER - TORO SENTINEL CENTRAL CONTROL SYSTEM SB-48-WS1 -U; W/ BUILT-IN NETWORK/ETHERNET PORT & 450 MHZ RADIO/ANTENNA; PROVIDE ONE (1) SHHR (SENTINEL HAND HELD REMOTE) W/ BATTERY; SEE CALLOUT ON L-25 OR CIRCUIT NUMBER # GPM -4 VALVE SIZE RAINBIRD W/ BALL PEB AUTOMATIC CONTROL VALVE VALVE (SPEARS MVPBV6S) OR CIRCUIT NUMBER # GPM 1 .5" O RAINBIRD PEB-PRS-D AUTOMATIC CONTROL VALVE W/ PRESSURE REGULATOR (SET TO VALVE SIZE 55 PSI) & BALL VALVE (SPEARS MVPBV65) 1 4 @ 2" RED & WHITE BRASS -24 L-27 MANUAL GATE VALVE LATERAL PIPE SIZE LEGEND POUNDS PER SQUARE REPRESENTATIVE SLIP SCHEDULE SPECIFICATION(S) STANDARD THREAD TYPICAL WIDTH WITH I11[6l:l ROUND VALVE BOX, TYP NI(1TF-C- IRRIGATION NOTES 1. THERE IS A LOSS OF PRESSURE IN EACH PIPE FITTING DUE TO FRICTION. THESE LOSSES ARE COMPENSATED FOR BY ADDING TEN (10) PERCENT TO THE MFRS RATED GPM FOR EACH NOZZLE. 2. LOCATE AUTOMATIC CONTROL VALVES IN PLANTING AREAS AT POINT OF EASY ACCESS. OWNER'S REP TO REVIEW & APPROVE FINAL LOCATION OF ALL QUICK COUPLERS & AUTOMATIC CONTROL VALVES PRIOR TO INSTALLATION. 3. CONTRACTOR SHALL COORDINATE IRRIGATION EQUIPMENT WITH PLANT MATERIAL, TO AVOID CONFLICTS, SPRAY BLOCKAGE & ANY OTHER ITEMS DEEMED APPROPRIATE BY THE OWNER'S REP. 4. EX STATIC PSI AT IRRIGATION METER IS 97 PSI. INFORMATION PROVIDED BY TODD BLACK, CITY OF RENTON, 1055 SOUTH GRADY WAY, RENTON, WA 98057; TELEPHONE (425) 430-6571 RECEIVED ON 01 /13/2015. PRIOR TO INSTALLATION OF IRRIGATION SYSTEM, CONTRACTOR SHALL FIELD VERIFY EX PSI @ EX PRESSURE REDUCING VALVE TO BE 85 PSI. NOTIFY OWNER'S REP OF ANY DISCREPANCIES BETWEEN THE DESIGN PSI & EX PSI PRIOR TO PROCEEDING WITH WORK. 5. SYSTEM DESIGNED TO 30 PSI (SPRAY AND ROTARY NOZZLE HEADS) & 50 PSI (ROTOR HEADS). 6. IRRIGATION CONTRACTOR SHALL COORDINATE IRRIGATION SLEEVING LOCATIONS WITH GENERAL CONTRACTOR. 7. DRAWING IS SCHEMATIC. ACTUAL LOCATIONS MAY VARY DUE TO PLANT MATERIALS OR EX CONDITIONS. 8. ALL IRRIGATION SLEEVING TO BE STAKED IN THE FIELD & REVIEWED BY OWNER'S REP PRIOR TO INSTALLATION. LOCATE SLEEVES ON DIMENSIONED "AS -BUILT" DRAWING TO ALLOW FOR FUTURE LOCATION & USE. ON "AS -BUILT" DRAWING, MAINLINE SHALL BE DIMENSIONED FROM ROADWAY CURB @ 30' OC TO ALLOW FOR FUTURE LOCATION. 9. CONTRACTOR TO AIR BLOW IRRIGATION SYSTEM THROUGH QUICK COUPLERS TO WINTERIZE IRRIGATION SYSTEM IN FIRST SEASON. 10. CONTRACTOR TO PROVIDE CONTINUOUS IRRIGATION OF EX RAINGARDENS DURING CONSTRUCTION. 11. PHASE I IRRIGATION VALVES AND SPRAY BODIES STOCKPILED DURING DEMOLITION MAY BE RE -USED IN PHASE 2 IRRIGATION. RE -USED EQUIPMENT MUST BE CORRECT PRODUCT AND SIZE SPECIFIED IN PHASE 2 DRAWINGS IN ORDER FOR RE -USE. DAMAGED IRRIGATION COMPONENTS SHALL NOT BE RE -USED. SUBMIT TO OWNER'S REP FOR REVIEW & APPROVAL PRIOR TO REUSE. 12. CONTRACTOR TO PROGRAM NEW CONTROLLER TO OPERATE ALL EX & NEW VALVES. VALVES SHALL BE PROGRAMMED TO OPERATE IN SEQUENTIAL ORDER AS SHOWN ON PLANS. RECORD RUN TIMES FOR EX VALVES PRIOR TO REMOVAL OF EX CONTROLLER. NEW CONTROLLER SHALL USE RUN TIME SCHEDULES FROM EX CONTROLLER AT CORRESPONDING EX VALVES WHEN RECONNECTED. CONTRACTOR TO COORDINATE WITH OWNER'S REP TO PROGRAM RUN TIMES AT NEW VALVES. 13. CONTRACTOR TO PROVIDE CONTINUOUS IRRIGATION OF ALL EX PLANTING AREAS DURING CONSTRUCTION. PI 'ANI RECTANGULAR VALVE BOX, TYP EDGE OF CURB OR SIDEWALK 1. CENTER BOXES OVER VALVES. 2. VALVE BOXES SHALL ALWAYS BE LOCATED WITHIN PLANTING AREAS & ON OPPOSITE SIDE OF PLANTER BEDS FROM ROADWAY WHEN WITHIN PLANTING STRIPS. 3. SET BOXES PARALLEL TO EACH OTHER AND PERPENDICULAR TO EDGE. 4. AVOID HEAVILY COMPACTING SOIL AROUND BOXES TO PREVENT DAMAGING VALVE BOXES. 5. AUTOMATIC & MANUAL CONTROL VALVES SHALL BE INDIVIDUALLY ENCLOSED IN A FIBERGLASS VALVE BOX W/ A LATCH LOCK COVER. THE BOTTOM SECTION IS TO BE SLOTTED SO AS TO EXTEND BELOW THE PIPE. EXTENSIONS SHALL BE ADDED AS REQUIRED TO MEET GRADES PER DETAILS. 6. BOTTOM OF VALVE BOXES SHALL BE COMPLETELY BLANKETED W/ GEOTEXTILE FOR SEPARATION. 7. PROVIDE 2 SETS OF ALL KEYS REQUIRED FOR VALVES, VALVE BOX COVERS, & PROTECTIVE SLEEVE COVERS UNLESS OTHERWISE NOTED. VALVE BOX LAYOUT NOT TO SCALE R-406974 A u