Loading...
HomeMy WebLinkAboutR-406708- �- iiiiiiii AI RIM' 20 87 - ' 158-IIE : RIM: 20 EE I jUM: 20.06 BRIM: 1991.RIM: 19. 97 /)RIM : 20.33 CB 12 �'� 1i• RIM, 2001J I RIM: 413v96 21.03 RIM: 20. 18 4 RIM. 20.44 CONTROL STRUCTURE C2 2 RIM: 19.80 RIM0.31 I�i3-99MJ• t ^ - 'tea. RIM: 20.12 � RIM 19 Ri J \ .. ... .... J J R�: 22.46 STMH 3 I 20 LF 12 EPEE XI TIKJG TY E 2 CB I STNVWC503 RIM=a9-IS19 84 \\IRI 49i) .8d 12" CONS NE IE-4 12.48 IE: i2YY 4"( .4d 3U" CONC SE IE-1151t DETENTION LAYOUT 25 20 15 10 14 LF 1TCPEP @071% B-iJ96 8'x12' MODULAR WE' IE IN 18.89 0.45% TREATMENT VAULT RIM: P£-59 213-5 � IE OUT: 32.6612.57 2 1. ISOLATIONIIJ IS ROWS ARE REQUIRED C2.8 AT DETENTION SYSTEM INLETS FOR SEDIMENTATION CONTROL 2. INSPECTION PORTS SHALL BE PROVIDED AT 25' AND AT EVERY INLET LOCATION 3. REFER TO SHOP DRAWINGS AND ASSOCIATED BUILDING PERMIT FOR ADDITIONAL DETAILS RIM: 19.69 19.63 PROPOI GRADE r EX 0+50 DETENTION PROFILE 1+00 1+50 O Know what's below. Call before you PROPOSED DETENTION FACILITY FOOTPRINT (7,318 SF) 18" INLET PIPE 12" OUTLET Inl>m=u IMP (DESIGN BY ENE SUITABLE COMPACTABLE FILL (AS NECESSARY - DESIGN BY ENGINEER OF RECORD) i LAYFIELD LP6 NON -WOVEN GEOTEXTIL (OR EQUAL) SURROUNDING MODULES AN STONE/SOIL INTERFAC PERMIT# VEGETATED AREA TO BE DESIGNED WITH ADEQUATE COMPACTED FILL FOR DESIGNED LOAD RATING (DESIGN BY ENGINEER OF RECORD) ITT IIC Wi 36" ` MIN. V MAX. I V-0" DEPTH SPECIFIED By V 2 ENGINEER 2OF " RECORD si'a' ANGULAR STONE STORMTANI(® MODULES MIN. [6- MIN] (36" x 18") MODEL ST-36 1. ISOLATION/DEBRIS ROWS ARE REQUIRED AT DETENTION SYSTEM INLETS FOR SEDIMENTATION CONTROL ENGINEER OF RECORD RESPONSIBLE FOR ENSURING 2. INSPECTION PORTS SHALL BE PROVIDED AT MANUFACTURER REP: ANDV GERSEN SUBGRADE SOILS MEET BEARING AND SETTLING 25'AND AT EVERY INLET LOCATION PHONE: 206-595-2203 REQUIREMENTS 3. REFER TO SHOP DRAWINGS AND PRODUCT LAYOUT: LAYFIELD GROUP '1 STORMTANK SYSTEM EMAIL ASSOCIATED BUILDING PERMIT FOR PHONE: 090807 ADDITIONAL DETAILS SEAT-rLEATTLE@LAVFIELDGROUP.COM ADDITIONAL LADDER RUNGS (IN SETS) TO ALLOW ACCESS TO TANKS OR VAULTS WHEN CATCH IS FILLED WITH WATER 2' MIN. CLEARANCE TO ANY PORTION OF FLOW RESTRICTOR TEE INCLUDING ELBOWS 0 ADJUST RIM PER RENTON STD. PLAN 204.50 AS NEEDED ROUND SOLID COVER MARKED FRAME AND LADDER OR FRAME OFFSET SEE NOTE 4 "DRAIN' WITH LOCKING BOLTS OK TO BE ABOVE GRADE a CHAIN -200#CAPACITY SLACK WHEN GATE IS DOWN a '.aAI FASTEN CHAIN TO FRAME 2.30' 0.751'1 DESIGN WATER A.r NOTCH o SURFACE EL.=f6!JIJ 1 I 600 DOWNTURNED ELBOW 16.81 2.0' MIN WITH 2.75"0 ORIFICE _ _ _ IEabi415.24 PIPE SUPPORT 16.17 5 SEE NOTE 6 WATERTIGHT CLEANOUT 14.51 SHEAR GATE 12"OUTLET PIPE a 18" INLET PIPE HIGH FLOW - � INVERT EL. 43.99 1INVERT EL. I AAA 13.87 13.54 12" SECTION OF PIPE ATTACHED BY V. V2.0' MIN 3ASKETED BAND TO ALLOW REMOVAL STANDARD GALVANIZED STEEL OR ALUMINUM 18" RISER PIPE BiLADDERISTEPS 0 RESTRICTOR PLATE WITH 2.25" ORIFICE 2.0' MIN 60"0 CONTROL STRUCTURE 4 SCALE: 1 =2" RECORD NOTE 12/03/2020 RMI ENDS ""w'"'SUBMITCITY OF BE RELIABLE. AHELEAST, BY NOTREOTHERS. WALE THIFOR IT ACCURACY TORE ERROR TO � ML x1SM�x. BEEISSIONS PICHISNOTBEBEENSIBLE INCORPORATE IWOTHIORCUMENTR C PtENTON OMISSIONSWWCX THOSE RELYING ON THIS RECORD DOCUMENT ME DOCUMENT ^r,ltl ltl A RESULT. INDEPENDENT IC TMS OF ACCURACY BEFORE VISED APELYITO OBTAIN INDEPENDENT VERIFICATION OF RSRLCORALV BEFOREAPRYING IT ML �� DATUM FoanNV PORPosE.� SK Planning/Building/Public Works Dept. vWmIIICN dIQ. NO- REVISION BY DATE APPR D•N M"EC01 y NOTES: r. 0 N N O I T u Lf) C) (`) C) C) ED 00 J T 2. OUTLET CAPACITY: 100-YEAR DEVELOPED PEAK FLOW. N C) 3. METAL PARTS PREFERRED TO BE STAINLESS STEEL ALUMINIZED C�I STEEL, OR ALUMINUM ALL OTHER STEEL PARTS MUST BE a GALVANIZED WITH TREATMENTS 1, 2, OR 5. 00 T 4. FRAME SO: O LADDERGATE STEPS OFFSETFROM A.CLEANOUT GATE I VISIBLE FROM TOP. A. CLIMB C B. CLIMB -DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE. -DO D- C. FRAME IS CLEAR OF CURB. 5. IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE I.D. LESS 114". 6. PROVIDE AT LEAST ONE W x.090 GAGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL. (MAXIMUM 3'-0" VERTICAL SPACING). 7. LOCATE ELBOW RESTRICTOR(S) AS NECESSARY TO PROVIDE MINIMUM CLEARANCE AS SHOWN. 8. LOCATE ADDITIONAL LADDER RUNGS IN STRUCTURES USED AS ACCESS TO TANKS AND VAULTS TO ALLOW ACCESS WHEN CATCH BASIN IS FILLED WITH WATER. 9. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL) WHEN CONNECTING TO AN EXISTING PIPE. USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 10. IF TEE SECTION IS USED ONLY FOR SPILL CONTROL, THEN ELBOW RESTRICTORS AND RESTRICTOR PLATES WITH ORIFICES ARE NOT REQUIRED. 1010100 / A�C✓ TACO MA • S EATTL E �oa, ad}�°8s®� S PO KAN E - TRI-CITIES �%0NA6 �$1 2215 North 30th Street, Suite 300 Tacoma, WA 98403 ps/Iy/zp17 253.383.2422 TEL 253.383.2572 FM vGGLahbl.mm WEB IN COMPLIANCE WITH CITY OF RENTON STANDARDS WALKER MAZDA DEALERSHIP 7/29/2019 AS-BUILTS INI JOB #2180100.11 MRSAHBL �,� DETENTION SYSTEM NOTES AND DETAILS NC2.2 R-4067 08