HomeMy WebLinkAboutW-406705CD25 25 C) III I Q FINISHED IS RACEAT qqI PIPE CENTE RLINE ROW 35 LF 0' DI CL52 E �Q0.0% EXISTING GRADE AT PIPE CENTERLINE 20 - 20 15 -F� 1 1 1 115 STA: 11+22.45, 0.00'LT CUT IN: (BY CITY FORCES) 1-12'x10'TEE DLML) 2-17' GATE VALVES ELxMJ( 1-10" GATE VALVE (FL%MJ) 2-12' SLEEVES(MJxMJ) 1-10- SLEEVE (MJxMJ) 1-GONG. THRUST BLOCK CONTRACTOR SHALL COORDINATE CUT-Iq OF VALVES AND FINAL CONNECTION WITH THE CITY FRENTON SEE CRY STD PLAN NO, 3004 FOR CONN CTION DETAILS 11+00 11+50 12+00 WATER MAIN PROFILE STA 11+00 TO 12+50 SCALE: 1"=20' HORIZONTAL V=2' VERTICAL 13%24' PLASTIC METER BOX EQUAL TO MIO-BTAtES PLASTIC. INC. BCF SERIES BESIDE 1324-18 MM 1.75- TRICK DUCTILE IRON DIAMOND PLATE COVER EQUAL TO MID -STATES PIASTCSE INC. MSCBC-1324-R INTR READER HD AND Y DRILLED HOLE FOR TOUCHREAD PIT LID (SEE DETAIL A -A) NEW 9" MIN 12" MAI FR D GRADE 35' MIN COVER CORPORATION STOP PoM PALL VALVE FORD TAPERED THREAD (CC). QUICK JOINT (3/4' FB10DO-3-0) OR AY MCDONALD 4701B (1" F81000-4-0) OR AY MCDWALO 47018 2 IN UNIMPROVED RIGHT OF WAY INSTALL METER BOX AT Z Z PROPERTY LINE MEN 12- Z LONG COPPER TAILPIECE. gl SPEAKER $� SUPPLED ev THE 12" - Cm io ME "K"_SOFi _.„u IF SERVICE LINE TO HOUSE IS TO BE INSTALLED IN THE FUNRE INSTALL FORD C14-33 OR 44 BUT v COMPRESSION COUPLING FORD Ass: 21-21EW000a3, OR BALL VALVE ON INLET AND NOTE: ALL METER BOXES INSTALLED SPAN CONCRETE OR PAVED DRIVEWAYS SI BE CAST-IRON EQUAL TO OLYMPIC FOUNDARY EXPANSION JOINTS MUSH BE INSTALLED ON BUM SIDES OF METER BOX. w z Y 3} r Lw 10 Of DIRECTION OF FLOW fI cP 0 3„ (MIN.) 6" MIN. 6"MIN.(TYP.) UNION (TYP.) PLAN < VMAX. m � E O O n M 5"MIN. TO CITY METER STACKED METER SECTION 6" MIN. FREE BOXES DRAINING GRAVEL NOTES: L ALL DOUBLE CHECK VALVE ASSEMBLIES (DCVA's) MUST BE LISTED ON LATEST LIST OF "BACKFLOW PREVENTION ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY STATE OF WASHINGTON DEPARTMENT OF HEALTH. 2, THE OWNER/APPLICANT MUST OBTAIN A SEPARATE CITY OF RENTON PLUMBING PERMIT FOR THE INSPECTION OF THE INSTALLATION OF THE DCVA AND PIPING. THE OWNER SHALL FURNISH, INSTALL AND MAINTAIN THE DCVA AND ALL PIPING AND APPURTENANCES SHOWN ON THIS PLAN. 3, THE DCVA MUST BE TESTED BY A STATE CERTIFIED BACKFLOW ASSEMBLY TESTER AFTER ITS INITIAL INSTALLATION, AFTER REPAIRS AND ANNUALLY THEREAFTER AT OWNER'S EXPENSE. A COPY OF THE TEST REPORT SHALL BE SENT OR FAXED TO CITY OF RENTON WATER UTILITY ENGINEERING DEPT., ATTN: WATER UTILITY CROSS -CONNECTION CONTROL SPECIALIST, FAX NO. 425-430-/241, 4, DCVA AND METER BOX SHALL BE LOCATED ON PRIVATE PROPERTY AND AS NEAR AS POSSIBLE TO THE WATER METER. PUBLIC WORKS %" TO 2" DOUBLE CHECK VALVE STD. PLAN - 240.8 +®+ DEPARTMENT ASSEMBLY FOR IRRIGATION OR RESIDENTIAL FIRE SPRINKLER MARCH 2O10 DOUBLE CHECK VALVE ASSEMBLY PERMIT# 120 VOLT ELECTRICAL OUTLET FOR HEAT TAPE. INSTALL HEAT TAPE 3 y FOR FREEZE PROTECTION CENTER BACKFLOW PREVENTOR IN I p REDUCED PRESSURE ENCLOSURE a BACKFLOW ASSEMBLY HE(RPBA) 3" MIN. E o 3" MIN. INSULATED ENCLOSUR 3" MIN. "HOT BOX" OR EQUAL 3/8" X 4" ANCHOR BOLTS PER MANUFACTURER 3" MIN. CONCRETE SLAB i UNION FINISHED GRADE FINISHED GRADE� rZIt }T. EQfir V DRAIN a? SEE NOTE 4 C MINIMUM SLEEVE FREE DRAINING a (TYP.) GRAVEL CONNECT TO a WATER METER IMMEDIATELY ADJACENT TO RPBA FLOW INE INSTALLED W/ APR ,D. TO OWNERS ELECTRICAL PANEL. FRONT VIEW MATERIAL PER UPC DIRECT BURIAL OR IN RIGID MOBR SIDE (SIZE AS REQ.) CONDUIT PER ELECTRICAL SIDE VIEW PERMIT REQUIREMENTS. NOTES: 1, ALL REDUCED PRESSURE BACKFLOW ASSEMBLIES (RPBA's) MUST BE LISTED ON LATEST LIST OF EACKFLOW PREVENTION ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY STATE OF WASHINGTON DEPARTMENT OF HEALTH. 2. THE OWNER/APPLICANT MUST OBTAIN A SEPARATE CITY OF RENTON PLUMBING PERMIT FOR THE INSPECTION OF THE INSTALLATION OF THE RPBA AND PIPING. THE OWNER SHALL FURNISH, INSTALL AND MAINTAIN THE RPBA AND ALL PIPING AND APPURTENANCES SHOWN ON THIS PLAN. 3. THE RPBA MUST BE TESTED BY A STATE CERTFIED BACKFLOW ASSEMBLY TESTER AFTER ITS INITIAL INSTALLATION, AFTER REPAIRS AND ANNUALLY THEREAFTER AT OWNER'S EXPENSE. A COPY OF THE TEST REPORT SHALL BE SENT OR FAXED TO CITY OF RENTON WATER UTILITY ENGINEERING DEPT., ATTN: WATER UTILITY CROSS -CONNECTION CONTROL SPECIALSIT, FAX NO. 425-430-7241. 4. DRAIN SHALL BE SIZED IN ACCORDANCE WITH AWWA CROSS CONNECTION CONTROL MANUAL STANDARDS 3" DRAIN FOR 1" OR SMALLER RPBA's, 4" DRAIN FOR 1.5" TO 2" RPSA's, 6" FOR 3" RPBA's. 5. RPBA AND ENCLOSURE SHALL BE LOCATED ON PRIVATE PROPERTY AND AS NEAR AS POSSIBLE TO THE WATER METER. STD. PL4N - 860.2 PUBLIC WORKS REDUCED PRESSURE BACKFLOW DEPARTMENT ASSEMBLY IN HOT BOX MARCH 2O10 A — A DRILL 2- DIA. HOLE FOR AMR (AUTOMATIC METER READ) MUCHREAD DEVICE L _ 2-1/2- MIN. FROM NEAREST AND FRONT EDGE OF PIT LID rwlcnL I C� RIB 0 I 0 NOTE: ME CENSER OF ME HOLE MUST BE AT LEAST 1- FROM UNDERNEATH! RIDS UNLESS THE RID SPACING ALLOWS TIE NUT TO TIGHTEN AGAINST THE OPEN SIDE BE MORE THAN Know what's below. ONE RIB. C811 before you 3 STD. PLAN — 220.E RECORD NOTE 12/01/2020 '�'� '"'M l- + =� + PUBLIC WORKS /4" AND 1" WATER SERVICE A ASEDO E B T BNExwML: ".n mwyU.M CITY OF DEPARTMENT SUBMITTED, IN PART, BY OTHERS. "ILE THIS INFORMATION IS BELIEVED TO \ *T *T NO EMBER 2009 BE RELIABLE. ABBE IS NOT RESPONSIBLE FOR ITS ACCURACY, OR ERROR OR �ML I�1VTO1V OMISSIONS WNICX MAY HAVE BEEN INCORPORATED IMOTXIS DOCUMENT ; 1 A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT PRE ADVISED TO 1 INCH WATER SERVICE OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT LwLx�[ M` �� DATUM 4 ORANV PDRPosE� SKKK\x Planning/Building/Public Works Dept. NOT TOSCALE N0. REVISION BY DATE APPR DWm— W ASSEMBLY / �!G/A�C✓ TACO MA • S EATTL E �oA, ad}�48s®� S PO KAN E • TRI-CITIES �aWTS �$1 2215 North 30th Street, Suite 300 Tacoma, WA 98403 psCTy/zp1/ 253.383.2422 TEL 253.383.2572 FAX WWW.ahbl.cam WEB IN COMPLIANCE WITH CITY OF RENTON STANDARDS WALKER MAZDA DEALERSHIP PERMIT SET AHBL JOB #2180100.11 WATER PROFILE IZ 4.5 7 O N N O T U LEE) C) M C) C) 00 Q J 111 Ir- 0 C) 0 00 T W-406705