HomeMy WebLinkAboutPN_Urban_Design_Regulations_Analysis_190916_v1CITC RENTON HEADQUARTERS
LAND USE PERMIT APPLICATION
URBAN DESIGN REGULATIONS ANALYSIS
SEPTEMBER 16, 2019
1 | P a g e
District: Project is located in District D since the site is located in a Commercial Arterial (CA)
Zone.
District D Standards:
1. The availability of natural light (both direct and reflected) and direct sun exposure
to nearby buildings and open space (except parking areas) shall be considered
when siting structures.
Siting of building is based on location of existing building, although existing building with
2nd level addition does not block availability to natural light for any adjacent sites.
2. Buildings shall be oriented to the street with clear connections to the sidewalk.
Building is located on or near Bronson Way, Garden Ave and 2nd Street, with clear
pathways connecting building entries and doors to the surrounding sidewalks on the
Public Right of Way.
3. The front entry of a building shall be oriented to the street or a landscaped
pedestrian-only courtyard.
Front Entry is oriented toward required pedestrian oriented plaza along Bronson Way.
4. Buildings with residential uses located at the street level shall be:
a. Set back from the sidewalk a minimum of ten feet (10') and feature
substantial landscaping between the sidewalk and the building (illustration
below); or
b. Have the ground floor residential uses raised above street level for residents’
privacy. No residential uses are provided in new building.
Building Entries:
Guidelines: Primary entries shall face the street, serve as a focal point, and allow space for
social interaction. All entries shall include features that make them easily identifiable while
reflecting the architectural character of the building. The primary entry shall be the most visually
prominent entry. Pedestrian access to the building from the sidewalk, parking lots, and/or other
areas shall be provided and shall enhance the overall quality of the pedestrian experience on the
site.
Primary Entrance is along Bronson Way N, includes a large expanse of curtain wall glazing
fronting an interior 2-level entrance atrium, making the south façade the primary focal
point of the building. CITC signage is planned above this entrance, and will be well lit at
night. Required public plaza is also at the entrance to the building marking it as an
important community space. A pedestrian walkway is planned parallel to the Alley (but
screened by landscaping on both sides. The path of travel will be denoted with patterned
concrete at all locations where this path crosses access drives for the Alley and the
parking lot. A special brick paver will be used at the main entrance of the building to
welcome pedestrians into the building and mark the entrance walk as unique.
All of the following are required:
1. The primary entrance of each building shall be:
a. Located on the facade facing a street, shall be prominent, visible from the street, connected by
a walkway to the public sidewalk, and include human-scale elements; and
b. Made visibly prominent by incorporating architectural features such as a facade overhang,
trellis, large entry doors, and/or
CITC RENTON HEADQUARTERS
LAND USE PERMIT APPLICATION
URBAN DESIGN REGULATIONS ANALYSIS
SEPTEMBER 16, 2019
2 | P a g e
ornamental lighting (illustration below).
2. Building entries from a street shall be clearly marked with canopies, architectural elements,
ornamental lighting, or landscaping and include weather protection at least four and one-half feet
(4-1/2') wide (illustration below). Buildings that are taller than thirty feet (30') in height shall also
ensure that the weather protection is proportional to the distance above ground level.
3. Building entries from a parking lot shall be subordinate to those related to the street.
4. Features such as entries, lobbies, and display windows shall be oriented to a street or
pedestrian-oriented space; otherwise, screening or decorative features should be incorporated.
5. Multiple buildings on the same site shall direct views to building entries by providing a
continuous network of pedestrian paths and open spaces that incorporate landscaping.
6. Ground floor residential units that are directly accessible from the street shall include:
a. Entries from front yards to provide transition space from the street; or
b. Entries from an open space such as a courtyard or garden that is accessible from the
street.
Primary entrance is highly visible with large expanses of glass, tall double storefront entry
doors (located in a recessed vestibule), a pedestrian scaled canopy, and includes
ornamental lighting at both the exterior and interior of the building. The entrance from
Bronson is highly visible while all other entry/exit doors are subordinate. This main entry
occurs in a covered exterior vestibule that measures 4 feet deep x 29 feet wide. The Lobby,
Library and Front Office Administration areas face the Plaza and Bronson Way. The
entrance passes through the public plaza which incorporates seating, a water feature,
specialty paving, landscaping and ornamental lighting.
Transition to Surrounding Development:
At least one of the following design elements shall be used to promote a transition to surrounding
uses:
1. Building proportions, including step-backs on upper levels in accordance with the surrounding
planned and existing land use forms; or
2. Building articulation to divide a larger architectural element into smaller increments; or
3. Roof lines, roof pitches, and roof shapes designed to reduce apparent bulk and transition with
existing development. Additionally, the Administrator may require increased setbacks at the side
or rear of a building in order to reduce the bulk and scale of larger buildings and/or so that
sunlight reaches adjacent and/or abutting yards.
Upper level of proposed building has a second level that steps back at least 15ft. from the
west and north property lines (adjacent to Residential properties and neighboring strip
mall). Lower level mass has been broken up between planes of solid walls and planes of
transparent curtain wall. The upper level mass jogs in and out to break down the perceived
scale and create visual interest. As the upper level jogs in these areas are typically entirely
glass, while the areas that protrude out are solid walls, mimicking a similar breakdown on
the lower level. A sunshading device wraps the south and southwest corner of the
building, breaking down the perceived scale of the building as viewed from Bronson and
tying in with a similar aesthetic screen used at the strip mall on the neighboring property
to the west. The northern face of the building incorporates planted green walls on all solid
CITC RENTON HEADQUARTERS
LAND USE PERMIT APPLICATION
URBAN DESIGN REGULATIONS ANALYSIS
SEPTEMBER 16, 2019
3 | P a g e
wall locations, used to soften the visual impact for the residential neighbors to the north
and northeast.
Service Element Location and Design
All of the following are required:
1. Service elements shall be located and designed to minimize the impacts on the pedestrian
environment and adjacent and/or abutting
uses. Service elements shall be concentrated and located where they are accessible to service
vehicles and convenient for tenant use.
2. In addition to standard enclosure requirements, garbage, recycling collection, and utility areas
shall be enclosed on all sides, include a roof and be screened around their perimeter by a wall or
fence and have self-closing doors (illustration below).
(2) Service structures have been provided along the interior alley and have been
surrounded by landscaping to minimize the visual impact of these structures as viewed
from the surrounding public right of ways. The structures are designed to match each
other and compliment the design of the main building. These structures consist of CMU
block walls, horizontal metal screens with integral sliding doors, a steel structure and
corrugated metal roofing. The garbage and recycling collection structure is located at
approximately mid-block along the alley, while the electrical transformer and outdoor
student break area are located close to 2nd Street N. Please reference Sheets A1.12 and
A1.13 for additional information. The Alley is intended primarily for Vehicular traffic, while
a separate pedestrian path is provided along the length of the property between the alley
and the parking lot. This path is surrounded on all sides by landscaping.
Gateways:
All of the following are required:
1. Developments located at district gateways shall be marked with visually prominent features .
2. Gateway elements shall be oriented toward and scaled for both pedestrians and vehicles.
3. Visual prominence shall be distinguished by two (2) or more of the following:
a. Public art;
b. Special landscape treatment;
c. Open space/plaza;
d. Landmark building form;
e. Special paving, unique pedestrian scale lighting, or bollards;
f. Prominent architectural features (trellis, arbor, pergola, or gazebo);
g. Neighborhood or district entry identification (commercial signs do not qualify).
The four items of visual prominence underlined above have been provided in the site
design. Elevation facing Bronson Way N, is primarily curtain wall glazing and includes a
raised roof monitor marking the building entry atrium location. This entry atrium will be lit
from the interior at night and act as a light beacon at this important gateway to downtown
Renton. A public plaza will be located at the corner of Bronson Way and Garden Ave and
will incorporate a water feature, concrete, steel and wood benches and defining elements,
decorative lighting, and special paving.
CITC RENTON HEADQUARTERS
LAND USE PERMIT APPLICATION
URBAN DESIGN REGULATIONS ANALYSIS
SEPTEMBER 16, 2019
4 | P a g e
Surface Parking:
Both of the following are required:
1. Parking shall be located so that no surface parking is located between:
a. A building and the front property line; and/or
b. A building and the side property line (when on a corner lot).
2. Parking shall be located so that it is screened from surrounding streets by buildings,
landscaping, and/or gateway features as dictated by location.
Surface parking is not located between building and the front property line. It is located on
the adjacent lot, and includes significant landscape buffers both in the right of way and
on-site. All of the stormwater runoff from the surface parking lot will be treated in the Bio-
Retention Planter along the west side of the parking lot.
Vehicular Access:
The following is required:
1. Access to parking lots and garages shall be from alleys, when available. If not available,
access shall occur at side streets.
2. The number of driveways and curb cuts shall be minimized for vehicular access purposes, so
that pedestrian circulation along the sidewalk is minimally impeded.
Primary access to the parking lot is from the interior Alley, which is proposed to be
designated as a one-way alley with access limited to 2nd street only in order to limit
impacts on traffic flow along Bronson Way. Secondary access and exiting from the
parking lot is located along 2nd St. Only one curb cut has been made for access and exiting
from the parking lot.
Pedestrian Circulation:
All of the following are required:
1. A pedestrian circulation system of pathways that are clearly delineated and connect buildings,
open space, and parking areas with the sidewalk system and abutting properties shall be
provided.
a. Pathways shall be located so that there are clear sight lines, to increase safety.
b. Pathways shall be an all-weather or appropriate permeable walking surface material,
unless the applicant can demonstrate that the proposed surface is appropriate for the
anticipated number of users and complementary to the design of the development.
2. Pathways within parking areas shall be provided and differentiated by material or texture (i.e.,
raised walkway, stamped concrete, or pavers) from abutting paving materials (illustration below).
Permeable materials are encouraged. The pathways shall be perpendicular to the applicable
building facade and no greater than one hundred fifty feet (150') apart.
3. Sidewalks and pathways along the facades of buildings shall be of sufficient width to
accommodate anticipated numbers of users. Specifically:
a. Sidewalks and pathways along the facades of mixed use and retail buildings one hundred
(100) or more feet in width (measured along the facade) shall provide sidewalks at least twelve
feet (12') in width. The pathway shall include an eight-foot (8') minimum
CITC RENTON HEADQUARTERS
LAND USE PERMIT APPLICATION
URBAN DESIGN REGULATIONS ANALYSIS
SEPTEMBER 16, 2019
5 | P a g e
unobstructed walking surface.
b. Interior pathways shall be provided and shall vary in width to establish a hierarchy. The widths
shall be based on the intended number of users; to be no smaller than five feet (5') and no
greater than twelve feet (12').
4. Mid-block connections between buildings shall be provided.
5. Permeable pavement pedestrian circulation features shall be used where feasible, consistent
with the Surface Water Design Manual.
New sidewalks will be installed per current City of Renton standards. Interior walks have
been provided that cut through the site between the Alley and surface parking lot to allow
for pedestrian circulation across the site and for pedestrians to use when walking from the
parking lot to the building entry. All walks on site will be constructed of concrete,
patterned concrete or special paving that is appropriate for the anticipated number of
users and complementary to the design of the development . Permeable paving is being
used at the public plaza on Bronson Way. Please reference Site Plan (A1.00) and Exterior
Material Schedule (A6.20) for additional information and specific product information.
Pedestrian Amenities:
All of the following are required:
1. Architectural elements that incorporate plants, particularly at building entrances, in publicly
accessible spaces and at facades along streets, shall be provided.
2. Amenities such as outdoor group seating, benches, transit shelters, fountains, and public art
shall be provided.
a. Site furniture shall be made of durable, vandal- and weather-resistant materials that
do not retain rainwater and can be reasonably maintained over an extended period of
time.
b. Site furniture and amenities shall not impede or block pedestrian access to public
spaces or building entrances.
3. Pedestrian overhead weather protection in the form of awnings, marquees, canopies, or
building overhangs shall be provided. These elements shall be a minimum of four and one-half
feet (4-1/2') wide along at least seventy five percent (75%) of the length of the building façade
facing the street, a maximum height of fifteen feet (15') above the ground elevation, and no lower
than eight feet (8') above ground level.
Public Plaza has been provided at Bronson Way which incorporates landscaping with
seasonal interest, benches, a water feature/ public art, and decorative lighting. The
benches are made of cast in place concrete, corten steel and cedar, all of which are
appropriate for exterior use and will need only minimal maintenance. Additionally, the
north façade of the building incorporates a planted wall with evergreen vines. None of the
plaza elements block the clear path to the building entrance from Bronson Way sidewalk.
Overhead weather protection has been provided at the main entry, as well as at all other
secondary entrance/exit doors in the form of recessed door alcoves.
Recreation Areas and Common Open Space:
All of the following are required:
1. Residential Requirements: N/A
CITC RENTON HEADQUARTERS
LAND USE PERMIT APPLICATION
URBAN DESIGN REGULATIONS ANALYSIS
SEPTEMBER 16, 2019
6 | P a g e
2. All buildings and developments with over thirty thousand (30,000) square feet of nonresidential
uses (excludes parking garage floorplate areas) shall provide pedestrian-oriented space.
a. The pedestrian-oriented space shall be provided according to the following formula: 1% of the
site area + 1% of the gross building area, at minimum.
b. The pedestrian-oriented space shall include all of the following:
i. Visual and pedestrian access (including barrier-free access) to the abutting structures from the
public right-of-way or a nonvehicular courtyard; and
ii. Paved walking surfaces of either concrete or approved unit paving; and
iii. On-site or building-mounted lighting providing at least four (4) foot-candles (average) on the
ground; and
iv. At least three (3) lineal feet of seating area (bench, ledge, etc.) or one individual seat per
sixty (60) square feet of plaza area or open space.
c. The following areas shall not count as pedestrian-oriented space:
i. The minimum required walkway. However, where walkways are widened or enhanced beyond
minimum requirements, the area may count as pedestrian-oriented space if the Administrator
determines such space meets the definition of pedestrian oriented space.
ii. Areas that abut landscaped parking lots, chain link fences, blank walls, and/or dumpsters or
service areas.
d. Outdoor storage (shopping carts, potting soil bags, firewood, etc.) is prohibited within
pedestrian-oriented space.
3. Open space substitution: see RMC 4-1-240.
All of the following are required:
1. Public plazas shall be provided at intersections identified in the Commercial Arterial Zone
Public Plaza Locations Map and as listed below.
2. The plaza shall measure no less than one thousand (1,000) square feet with a minimum
dimension of twenty feet (20') on one side abutting the sidewalk.
3. The public plaza must be landscaped consistent with RMC 4-4-070, including at minimum
street trees, decorative paving, pedestrian-scaled lighting, and seating. Vegetated low impact
development facilities may be used in the plaza where feasible and designed consistent with the
Surface Water Design Manual. Such facilities shall count towards no more than fifty percent
(50%) of the plaza requirement.
4. Public plazas are to be provided at the following intersections:
b. Bronson Area: Intersections with Bronson Way North at:
ii. Garden Avenue N.
A plaza is being provided at the corner of Bronson Way and Garden Ave as required by the
RMC. Minimum 1149 sf plaza is required (1% of the site area + 1% of the gross building
area). Actual Plaza size consists of 1490sf of hardscape/ open area and 1948sf of
landscape areas. The Plaza hardscape bordering the right of way sidewalk is
approximately 25ft. wide, while the entire plaza area including landscaping is
approximately 104ft. wide. 3 Lineal feet of bench is required per 60sf of Plaza area,
therefore 57.45lf of benches is required ((1490sf/ 60sf) x 3lf) linear feet of benches are
required in the Plaza, and the actual length of benches proposed is 58.5 linear feet. All
landscaping and materials will be consistent with RMC requirements.
CITC RENTON HEADQUARTERS
LAND USE PERMIT APPLICATION
URBAN DESIGN REGULATIONS ANALYSIS
SEPTEMBER 16, 2019
7 | P a g e
Building Character and Massing:
Both of the following are required:
1. All building facades shall include modulation or articulation at intervals of no more than forty
feet (40').
2. Modulations shall be a minimum of two feet (2') deep, sixteen feet (16') in height, and eight feet
(8') in width.
3. Buildings greater than one hundred sixty feet (160') in length shall provide a variety of
modulations and articulations to reduce the apparent bulk and scale of the facade (illustration in
District B, below); or provide an additional special feature such as a clock tower, courtyard,
fountain, or public gathering area.
The lower level re-uses the existing building on site so lower level articulation in plan is
not possible or practical, but material articulation has been provided with alternating
planes of solid metal siding and planes of glazing. The upper level incorporates deeper
modulations at multiple locations at intervals of no more than 40ft with depths of
approximately 13’-6”.
Ground Level Details:
All of the following are required:
1. Human-scaled elements such as a lighting fixture, trellis, or other landscape feature shall be
provided along the facade’s ground floor.
2. Any facade visible to the public shall be comprised of at least fifty percent (50%) transparent
windows and/or doors for at least the portion of the ground floor facade that is between four feet
(4') and eight feet (8') above ground (as measured on the true elevation).
3. Upper portions of building facades shall have clear windows with visibility into and out of the
building. However, screening may be applied to provide shade and energy efficiency. The
minimum amount of light transmittance for windows shall be fifty percent (50%).
4. Display windows shall be designed for frequent change of merchandise, rather than permanent
displays.
5. Where windows or storefronts occur, they must principally contain clear glazing.
Human scaled elements such as lighting fixtures, sunshade/ canopy at entry, trees and
other landscaping are integrated into the first level design and surrounding site design. All
Facades along streets (Bronson, Garden and 2nd have at least 50% glazing between 4’-8’).
All glass on the project will be clear vision glass with the exception of some glass
spandrel panels at floor locations. Sunshading devices are integrated at the south façade
and around the southwest corner, but they begin above 8 feet, so pedestrians will still be
able to see in and out of the glazing provided.
All of the following are prohibited:
1. Tinted and dark glass, highly reflective (mirror-type) glass and film.
2. Untreated blank walls visible from public streets, sidewalks, or interior pedestrian pathways.
a. A wall (including building facades and retaining walls) is considered a blank wall if:
i. It is a ground floor wall or portion of a ground floor wall over six feet (6') in height, has a
horizontal length greater than
fifteen feet (15'), and does not include a window, door, building modulation or other architectural
detailing; or
CITC RENTON HEADQUARTERS
LAND USE PERMIT APPLICATION
URBAN DESIGN REGULATIONS ANALYSIS
SEPTEMBER 16, 2019
8 | P a g e
ii. Any portion of a ground floor wall has a surface area of four hundred (400) square feet or
greater and does not include
a window, door, building modulation or other architectural detailing.
b. If blank walls are required or unavoidable, they shall be treated. The treatment shall be
proportional to the wall and use
one or more of the following (illustration below):
i. A planting bed at least five feet (5') in width abutting the blank wall that contains trees, shrubs,
evergreen ground
cover, or vines;
ii. Trellis or other vine supports with evergreen climbing vines;
iii. Architectural detailing such as reveals, contrasting materials, or other special detailing that
meets the intent of this
standard;
iv. Artwork, such as bas-relief sculpture, mural, or similar; or
v. Seating area with special paving and seasona l planting.
Blank walls under the definition outlined above do occu r around the ground level of the
building. The ground level was intentionally designed to provide large vertical ribbons of
glass separated by vertical ribbons of solid wall. The three sides of the building fronting
pedestrian walkways have significant quantities of full height glass (6,109 sf of glazing and
6,799sf of solid walls; over 47% glazing), which is significantly more than what the average
office building with typical punched windows would incorporate on the ground level.
Since the existing building is being re-used, there are only certain areas that have space
outside of the building to incorporate landscaping and/or climbing vines. The building
façade facing Bronson Way N incorporates approximately 61’-6” of landscaping frontage,
while the façade facing 2nd St N incorporates 83 ft of adjacent landscaping (61 feet of
which will incorporate a full height planted wall with climbing vines incorporated).
Building Roof Lines:
The following is required:
At least one of the following elements shall be used to create varied and interesting roof profiles
(illustration below):
1. Extended parapets;
2. Feature elements projecting above parapets;
3. Projected cornices;
4. Pitched or sloped roofs.
5. Roof mounted mechanical equipment shall not be visible to pedestrians.
6. Buildings containing predominantly residential uses shall have pitched roofs with a minimum
slope of one to four (1:4) and shall have dormers or interesting roof forms that break up the
massiveness of an uninterrupted sloping roof.
Extended parapets and sections of curtain wall that extend beyond the roof to become
guardrails are both included in this project design, Additionally, the project includes 3 roof
monitors above interior atrium spaces which are wrapped in glass and will bring natural
light into the interior during the day and will appear as interior lit beacons at night. The
CITC RENTON HEADQUARTERS
LAND USE PERMIT APPLICATION
URBAN DESIGN REGULATIONS ANALYSIS
SEPTEMBER 16, 2019
9 | P a g e
second level also incorporates (4) occupiable roof decks with landscaping planed as
screening at the edge of several. All rooftop mechanical equipment will be screened by
perforated corrugated metal panels, and this mechanical penthouse is set back
significantly from the lower level roof edge, obscuring it from view from pedestrians down
on the street.
Building Materials:
All of the following are required:
1. All sides of buildings visible from a street, pathway, parking area, or open space shall be
finished with the same building materials, detailing, and color scheme. A different treatment may
be used if the materials are of the same quality.
2. All buildings shall use material variations such as colors, brick or metal banding, patter ns or
textural changes.
3. Materials, individually or in combination, shall have texture, pattern, and be detailed on all
visible facades.
4. Materials shall be durable, high quality, and consistent with more traditional urban
development, such as brick, integrally colored concrete masonry, pre-finished metal, stone, steel,
glass and cast-in-place concrete.
5. If concrete is used, walls shall be enhanced by techniques such as texturing, reveals, and/or
coloring with a concrete coating or admixture.
6. If concrete block walls are used, they shall be enhanced with integral color, textured blocks and
colored mortar, decorative bond pattern and/or shall incorporate other masonry materials.
All exterior materials fall within a similar color and material palette. The primary exterior
materials are horizontal metal panels with 2” reveals, vertical corrugated metal panels,
high quality curtain wall glazing, overhead aluminum and glass sectional garage doors. All
exterior materials were selected for their quality, durability, and visual interest. The
interplay of shadows, natural light and layering has been utilized consistently throughout
the exterior design, with the undulating metal panels and reveals as well as through the
incorporation of a large steel sunshade structure installed outboard of the curtain wall at
Bronson Way N and around the southwest corner. The interior of the building will be
highly visible from the exterior and includes visible structural steel “braced frames”, glu-
lam beams (both existing and new), wood T&G decking and exposed concrete slabs.
Lighting:
All of the following are required:
1. Pedestrian-scale lighting shall be provided at primary and secondary building
entrances. Examples include sconces on building facades, awnings with downlighting
and decorative street lighting.
2. Accent lighting shall also be provided on building facades (such as sconces)
and/or to illuminate other key elements of the site such as gateways, specimen
trees, other significant landscaping, water features, and/or artwork.
3. Downlighting shall be used in all cases to assure safe pedestrian and vehicular
movement, unless alternative pedestrian-scale lighting has been approved
administratively or is specifically listed as exempt from provisions located in RMC
CITC RENTON HEADQUARTERS
LAND USE PERMIT APPLICATION
URBAN DESIGN REGULATIONS ANALYSIS
SEPTEMBER 16, 2019
10 | P a g e
4-4-075, Lighting, Exterior On-Site (i.e., signage, governmental flags, temporary
holiday or decorative lighting, right-of-way lighting, etc.).
In keeping with the stated aims of the City of Renton, the proposed
exterior lighting for this project consists of:
• Building mounted lighting aimed to accent architectural features.
• Building mounted recessed lighting to illuminate egress
entry/exits and egress pathways.
• Accent lighting within architectural features of the entry plaza
including curved feature walls and a central fountain.
• Ground mounted low-level lighting to illuminate entry plaza
egress path.
• Ground mounted aimable accent lighting to highlight landscape
elements.
• Pole mounted lighting to provide general illumination to parking
and circulation areas.
Proposed interior lighting for the building will be visible from the
surrounding area and is intended to highlight interior architectural
features, provide a warm glow to the interior views of the building, and
act as a subtle welcoming presence in the neighborhood.
Both interior and exterior lighting design is intended to minimize glare,
eliminate light spill onto neighboring properties, and achieve the
objectives laid out by the City of Renton.
Lighting that is visible to the project surroundings will be scheduled for
the open hours of the building with light levels being reduced to
minimum levels needed for neighborhood safety during the un-occupied
hours of the building.