Loading...
HomeMy WebLinkAboutR_401331LAKE WASH NGTON SUMMER o EL 15.18 (NGVD29) WINTER EL 13.18 (NGVD29) N: 186006.67 E: 1300291.2E ----------------------I-- I 33 "C I IL---— ---------------------T— I I I 3s o I I I� I I I I o_ I I ---- � s I _ \ \ 7 - \ I I \ I I 4), Ber erABAM CALL 48 HOURS " BEFORE YOU DIG 33301 9th Avenue South, Suite 300 Federal Way, Washington 98003-2600 1-800-424-5555 (206) 431-2300 Fax: (206) 431-2250 SYM REVISION BY - APRON R INFRASTRUCTURE W4700331 ABAM A CITY OF RENTON COMMENTS W4700331 ABAM B PERIMETER SECURITY FENCE W47003311 ABAM APPROVED DATE SYM SPT 06/08/18 SPT 10/01/18 SPT 12/14/18 REVISION MATCHLINE, SEE SHEET C84 I N: 185988.62 E: 1300470.87 N: 185959.51 E: 1300478.43 \ I \ I CI N: 185944.39 \ i E: 1300420.22 N: 185915.30 E: 1300427.85 O I vx WINGTIP CLEARANCE 1 \1 \ Iz G o X x — lo I� Q 0 0 IC 0 0 0 0 I= " Iz to I� c� I� I� w U' I I I I o N: 185850.84 E: 1300226.14 MATCHLINE, SEE SHEET C82 BY I APPROVED I DATE N: 185862.37 E: 1300223.15 Irr' I� z z o I= Q Iz � z �C z O I� o Iw N: 185836.67 E: 1300171.61 ' -r - I— WINGTIP CLEARANCE II I UJU I J.UU E: 1300140.62 A' 4-81 BUILDING )\VMAIVM NVI&S303d L / V J J Y U O —J m 811C LLJ o n N: 185824.93 o o o o E: 1300174.66 R5 II �HARDSTAND O O (0 P. of WA �f ""AOL//V" x 31271 w� ��ssioNaL 8' C ' 20 0 20 40 C scale feet DRAWN DATE SUBTITLE ACCEPTABILITY JDM 06/08/18 THIS DESIGN AND/OR CHECKED SPECIFICATION IS APPROVED SPT 06/08/18 ENGINEER TITLE APPROVED BY DEPT. I DATE JLC 06/08/18 CIVIL MASTER 12"C O v Slddd 03d3A00 121) -.011111111 GENERAL NOTES 1. CONCEPTUAL AIRCRAFT LAYOUT ORIENTATION PER BOEING DIRECTION. 2. HORIZONTAL DATUM: WASHINGTON STATE COORDINATE SYSTEM, NORTH ZONE, NORTH AMERICA DATUM 1983(91). VERTICAL DATUM: NATIONAL GEODETIC VERTICAL DATUM 1929 (NGVD29). VERTICAL DATUM CONVERSION: NGVD29 TO THE NORTH AMERICAN VERTICAL DATUM 1988 (NAVD88) = NGVD29 + 3.60 FEET. 3. THERE SHALL BE NO EXPOSED GALVANIZED MATERIALS, COATINGS OR ZINC APPLIED SURFACE TREATMENTS ON ANY EXTERIOR OR UNDERGROUND MATERIALS OR SURFACES. ALL GALVANIZED OR ZINC APPLIED MATERIALS OR COATINGS SHALL BE PERMANENTLY PAINTED OR COATED TO PREVENT EXPOSURE OF THE GALVANIZED/ZINC MATERIALS PRIOR TO INSTALLATION OR COMPLETION OF CONSTRUCTION. 4. ABOVE GRADE DRAINAGE AND UTILITY APPURTENANCES ARE SHOWN ON THIS PLAN FOR REFERENCE ONLY. SEE DRAINAGE, MECHANICAL, OR ELECTRICAL PLANS FOR DESIGN DETAILS. INSTALL BOLLARD PROTECTION AT ABOVE GRADE UTILITIES PER TYPICAL SPACING LAYOUTS. SEE DETAIL S50��7 CONSTRUCTION NOTES 1� ACTUATED STORMWATER VALVE 2� BACK OF CURB 3� HARDSTAND 4� UTILITY STAND WITH AIR MANIFOLD AND YARD HYDRANT 5� STORM DRAINAGE VAULT FIRE HYDRANT 7� POST INDICATOR SECTION VALVE CIVIL PERMIT CIVIL SITE PLAN APRON R INFRASTRUCTURE RENTON SITE SITE KEY PLAN SCALE: N.T.S. R-401331 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING SURFACE WATER UTILITY atowler 12/20/201801 rstraka 12/20/2018 Ul W4700331 J' `' /� D 12/ 14/ 18 SHEET C83 C14- JOB NO. COMP NO. W4700331 RENTON, WA DWG N0. 4—APRON—R—C83