Loading...
HomeMy WebLinkAboutR_401341J m a .Z] LAKE WASH N GTO N I — — SUMMER EL 15.18 (NGVD29) WINTER EL 13.18 (NGVD29) I T HOUS — PR�T1' LINE I.� I � � V \ ORDINARY HIGH WATER 11 --- - - - - ---- EASEMENT LINE (TYP) / / , , _ _ � +' �: / - - / I I 00151 / I I I 4 4-82 BUILDING o ' ` / I A 71 — � � -- � � o � °°� m ��---- .. "alp 8 I >, 4 81 BUILDING 31 CALL 48 HOURS BEFORE YOU DIG 1-800-424-5555 SYM REVISION APRON R INFRASTRUCTURE A CITY OF RENTON COMMENTS B CONSTRUCTION PHASING & PIPE DEPTH LLJ Hq ReoR 4-41 BUILDING —� — . i . — . — —�N� - — — — — — — I =I a , I -- -- -- -- I -I- ^` — --- I — ------ �L� —--------r`�--- --� ra-- MI - � • � �" T I� I, g i la ; I M I � I I BY W4700331 ABAM W4700331 ABAM W4700331 ABAM 4-20 BUILDING AREA 2: PHASE 7 CONSTRUCTION PHASING KEY PLAN X j NASE 7 (AREA 2) 1. ABANDON IN PLACE OR REMOVE REMAINING UTILITIES AS SHOWN IN REMOVAL PLANS UP TO AND INCLUDING EXISTING j UTILIDOR NORTH OF BUILDING 4-82. 2. CONSTRUCT SLOTTED DRAIN NORTH OF BLDG 4-82 AND PROVIDE TEMPORARY CONNECTION TO EXISTING •1106A-18, 1106-18 • 1107A-18, 1107-18, 1107B, TEMPORARY CONNECTION TO EX 417 3. PARTIALLY REMOVE EXISTING PAVEMENT AND WALL SUPPORTS AS SHOWN IN STRUCTURAL PLANS TO CONSTRUCT NORTH -SOUTH STORM CONVEYANCE. •1118-18, 1119-18 IN -WATER WORK WINDOW NOV 16 - DEC 31 2020: 4. CONSTRUCT OUTFALL 002A IMPROVEMENTS. 5. CONSTRUCT CATHODIC PROTECTION IMPROVEMENTS AND FLUME WALL REPAIRS. POST IN -WATER WORK: 6. CONSTRUCT REMAINING STORMWATER SYSTEMS • 1108-18, 1109-18, 1110-18, 1111-18, 1112-18, OWS-066, RTU-16, 111-18, 1114-18, 1115-18, 1116-18, 1118-18, 1117-18 •URE 726-18, UR, URE 725-18, 1112-18 •1107-18, 1110-18 APPROVED DATE SYM SPT 06/08/18 SPT 10/01/18 SPT 1 10/09/18 REVISION 7. CONSTRUCT WALL AS SHOWN IN STRUCTURAL PLANS AND BRING AREA 2 TO GRADE. 8. COMPLETE CONSTRUCTION OF AREA 2 FIRE PROTECTION, MECHANICAL, ELECTRICAL, DATA, AND GROUNDING SYSTEMS. 7. CONSTRUCT ALL FINISHED PAVEMENT DURING STRATEGIC TRANSIT ROUTE CLOSURES. COORDINATE WITH BOEING REPRESENTATIVE. 8. COMPLETE UPLAND IMPROVEMENT PUNCHLIST ITEMS. IN -WATER WORK JUL 16 - AUG 1 2021: 9. COMPLETE IN -WATER IMPROVEMENT PUNCHLIST ITEMS AS NEEDED. 10. BY I APPROVED I DATE F n P. of WA �f BOE//V� � �P ��• �1 x 31271 w� ��ssioNaL 200-FT SHORELINE SETBACK NEW BUILDING 4-87 TO BE CONSTRUCTED UNDER SEPARATE PERMIT. i BergerABAM 33301 9th Avenue South, Suite 300 Federal Way, Washington 98003-2600 (206) 431-2300 Fax:(206) 431-2250 DRAWN DATE SUBTITLE ACCEPTABILITY BEE 06/08/18 THIS DESIGN AND/OR CHECKED SPECIFICATION IS APPROVED SPT 06/08/18 ENGINEER TITLE APPROVED BY DEPT. I DATE BEE 06/08/18 CIVIL MASTER CIVIL PERMIT PHASING PLAN - AREA 2: PHASE 7 APRON R INFRASTRUCTURE RENTON SITE SITE a a •o 2 b e ° ut° 0 �I 4-86 BUILDING R-401341 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING afowler 12/20/2018 01 wI` \LIV W4700331 J `' /� D 10/09/ 18 SHEET U500-1 H C24- JOB N0. COMP NO. W4700331 DWG N0. RENTON, WA 4-APRON-R-0500-1 H