Loading...
HomeMy WebLinkAboutR_401350MATCHLINE, SEE SHEET C500-2K O i O w 75 N O N CO CD u; 0 z 0 1= 0 ca J 4), Ber erABAM CALL 48 HOURS " BEFORE YOU DIG 33301 9th Avenue South, Suite 300 Federal Way, Washington 98003-2600 1-800-424-5555 (206) 431-2300 Fax: (206) 431-2250 SYM I REVISION I BY — I APRON R INFRASTRUCTURE W47003311 ABAM INSALLATION OF RETAINING WALLS TO BE COMPLETED UNDER A SEPARATE BUILDING PERMIT APPROVED I DATE SPT 06/08/18 SYM C41wflell BY I APPROVED I DATE P. of WAsh� �f x 31271 w� ��ssioNaL 1 " = 20' 20 0 20 40 scale feet UNAWN UAI L SUBTITLE ACCEPTABILITY JDM 06 08 18 THIS DESIGN AND/OR CHECKED SPECIFICATION IS APPROVED SPT 06 08 18 ENGINEER TITLE APPROVED BY DEPT. I DATE BEE 06/08/18 GEOSYNTHETIC RETAINING WALL BENCH ELEVATION: 6.0 FT GEOSYNTHETIC RETAINING WALL BENCH ELEVATION: 7.5 FT GEOSYNTHETIC RETAINING WALL BENCH ELEVATION: 9.0 FT GEOSYNTHETIC RETAINING WALL BENCH ELEVATION: 10.5 FT GEOSYNTHETIC RETAINING WALL BENCH ELEVATION: 12.0 FT IN —WATER FILL SUBGRADE IMPROVEMENT BENCH ELEVATION: 13.0 FT FACE OF STRUCTURAL EARTH WALL *BENCH ELEVATION IS DEFINED AS THE BOTTOM OF SUBGRADE IMPROVEMENTS AND THE TOP OF DRIVEN TIMBER PILE. SEE GENERAL NOTE 3. GENERAL NOTES 1. HORIZONTAL DATUM: WASHINGTON STATE COORDINATE SYSTEM, NORTH ZONE, NORTH AMERICA DATUM 1983(91). VERTICAL DATUM: NATIONAL GEODETIC VERTICAL DATUM 1929 (NGVD29). VERTICAL DATUM CONVERSION: NGVD29 TO THE NORTH AMERICAN VERTICAL DATUM 1988 (NAVD88) _ NGVD29 + 3.60 FEET. 2. THERE SHALL BE NO EXPOSED GALVANIZED MATERIALS, COATINGS OR ZINC APPLIED SURFACE TREATMENTS ON ANY EXTERIOR OR UNDERGROUND MATERIALS OR SURFACES. ALL GALVANIZED OR ZINC APPLIED MATERIALS OR COATINGS SHALL BE PERMANENTLY PAINTED OR COATED TO PREVENT EXPOSURE OF THE GALVANIZED/ZINC MATERIALS PRIOR TO INSTALLATION OR COMPLETION OF CONSTRUCTION. 3. THE MUDLINE ELEVATIONS SHOWN BELOW PILE SUPPORTED STRUCTURES IN THESE PLANS ARE ASSUMED. TOP OF PILE/BOTTOM OF SUBGRADE SHALL BE ELEVATION 13.0 OR 2 FEET BELOW THE FIELD VERIFIED MUDLINE, WHICHEVER IS DEEPER. 4. SEE SHEET C500-2M FOR STRUCTURAL EARTH WALL PROFILES. 5. GEOSYNTHETIC RETAINING WALL SHALL BE CONSTRUCTED PER DETAIL 1 ON SHEET C500-2S. 6. SUBGRADE IMPROVEMENTS SHALL BE CONSTRUCTED PER DETAIL 2 ON SHEET C500-2S. 7. IN —WATER FILL SHALL BE CONSTRUCTED PER DETAIL 3 ON SHEET C500-2S. 8. SEE STRUCTURAL PLANS FOR STAGED DEMOLITION OF PILE SUPPORTED STRUCTURES, TEMPORARY SHEET PILE CONTAINMENT WALL, AND PERMANENT CONCRETE STEM WALL DETAILS. CONSTRUCTION NOTES TIMBER PILE OUTSIDE OF TEMPORARY SHEET PILE CONTAINMENT WALL DRIVE EXISTING TIMBER PILE TO BENCH ELEVATION OR 2'-0" MINIMUM BELOW EXISTING MUDLINE. SEE GENERAL NOTE 3. :� NORTH FACE OF GEOSYNTHETIC RETAINING WALL ALIGNMENT :� SOUTH FACE OF GEOSYNTHETIC RETAINING WALL ALIGNMENT 5� TEMPORARY SHEET PILE CONTAINMENT WALL CIVIL PERMIT, SUBGRADE IMPROVEMENT PLAN - SHEET 1 KEY PLAN SCALE: N.T.S. R-401350 IN COMPLIANCE WITH CITY OF RENTON STANDARDS NTEII011YOSsl DEVELOPMENT ENGINEERING afowler 12/20/2018 06/08/18 APRON R INFRASTRUCTURE C500_2J C33 RENTON SITE JOB NO. COMP NO. W4700331 SITE RENTON, Wq Dwc No. 4—APRON—R—0500-2J CIVIL MASTER