Loading...
HomeMy WebLinkAboutR_401380OHW Umw vnVV VI ITV WI ITT M O O i LU 75 N 00 N L 0 z E 0 c 0 ca V) !n J SITE SPECIFIC DATA PROJECT NAME 4851 - SOUTH SHORE OF LAKE WA - APRON R PROJECT LOCATION RENTON, WA STRUCTURE ID RTU-12 TREATMENT REQUIRED VOLUME BASED (CF) FLOW BASED (CFS) 0.20 TREATMENT HGL AVAILABLE (FT) N/A PEAK BYPASS REQUIRED (CFS) - IF APPLICABLE 0.789 PIPE DATA I.E. MATERIAL DIAMETER INLET PIPE 16.30 PVC 8" OUTLET PIPE 15.20 HDPE 12" PRETREATMENT BIOFIL TRA TION DISCHARGE RIM ELEVATION 18.63 18.61 18.63 SURFACE LOAD 120 KIPS 120 KIPS 120 KIPS FRAME & COVER (2) 36 " X 36" () 36 " X 36- (2) 30 " X 30 " INDUSTRIAL MEDIA VOLUME (CY) 5.70 INDUSTRIAL MEDIA DELIVERY METHOD PER CONTRACT ORIFICE SIZE (DIA. INCHES) (2) 01.94 " NOTES: INSTALLATION NOTES 1. CONTRACTOR TO PROVIDE ALL LABOR, EQUIPMENT MATERIALS AND INCIDENTALS REQUIRED TO OFFLOAD AND INSTALL THE SYSTEM AND APPURTENANCES IN ACCORDANCE WITH THIS DRAWING AND THE MANUFACTURERS SPECIFICATIONS, UNLESS OTHERWISE STATED IN MANUFACTURERS CONTRACT 2. UNIT MUST BE INSTALLED ON LEVEL BASE. MANUFACTURER RECOMMENDS A MINIMUM 6" LEVEL ROCK BASE UNLESS SPECIFIED BY THE PROJECT ENGINEER. CONTRACTOR IS RESPONSIBLE TO VERIFY PROJECT ENGINEERS RECOMMENDED BASE SPECIFICATIONS. J. ALL PIPES MUST BE FLUSH WITH INSIDE SURFACE OF CONCRETE. (PIPES CANNOT INTRUDE BEYOND FLUSH). INVERT OF OUTFLOW PIPE MUST BE FLUSH WITH DISCHARGE CHAMBER FLOOR. ALL GAPS AROUND PIPES SHALL BE SEALED WATER TIGHT WITH A NON -SHRINK GROUT PER MANUFACTURERS STANDARD CONNECTION DETAIL AND SHALL MEET OR EXCEED REGIONAL PIPE CONNECTION STANDARDS. 4. CONTRACTOR TO SUPPLY AND INSTALL ALL EXTERNAL CONNECTING PIPES. 5. CONTRACTOR RESPONSIBLE FOR INSTALLATION OF ALL RISERS, MANHOLES, AND HATCHES. CONTRACTOR TO GROUT ALL MANHOLES AND HATCHES TO MATCH FINISHED SURFACE UNLESS SPECIFIED OTHERWISE. 6. DRIP OR SPRAY IRRIGATION REQUIRED ON ALL UNITS WITH VEGETATION. GENERAL NOTES ACTUATED VALVE � i r 011 nvn PATENTED VERTICAL T is L;H I L VALVL NEENAH FOUNDRY NEENAH FOUNDRY [NEENAH FOUNDRY I R-3498-R3S SPRING R-3498-R2S SPRING PERIMETER UNDERORAINV010 AREA MANIFOLD R-3498-R3S SPRING ASSIST HATCH ASSIST HATCHES ASSIST HATCH ELEV-18.71 ELEV-18.71 N-185667.43 N-185673.73� f NEENAH FOUNDRY NEENAH FOUNDRY E-1299698.45 E-1299722.86 _'�r..a..:"y.T•.. �V..+. .i ..!er r.r+r..V N �.�k!+` � �,q T ^.up.r' .ti -�?y� I R 3498 R3S S R 3498 R2S S R!N M..;.; ASSIST HATCH ASSIST HATCH s INDUSTRIAL MEDIA , „ ` x.. 4a 1 BED C/L - ,.,� l U _ CHECKMATE IN -LINE VALVE - NEENAH FOUNDRY -'e'" ❑ ❑ 'El- �❑ I I---------------- R-3498-P2S SPRING ( (o❑ ❑❑?�.y. AssIsr HArcH -------- I ------- - 4 I I I IELEV- 18.65 .............. I ............ 1: I --- ---- ---- ----I --- ---- ---- ----I -4" ELEV-18.65 Lj N-185658.51 N-185664.81 _3'-8"� 8" E-1299700.76 E-1299725.16 INFLOW PIPE OUTFLOW PIPE "i SEE NOTES NEENAH FOUNDRY PRE FILTER DRAIN DOWN LINE SEE NOTES 1?-3498-1?2S SPRING CARTRIDGE LEFT END VIEW ASSIST HATCHES � S1S S1S S1S S1S S1S S1S S1S PLAN VIEW 46 HIGH FLOW BYPASS RTU -12 PAN /�/ SCALE: NTS ' V NEENAH FOUNDRY 12" GATE VALVE R-3498-P2S ; SPRING ASSIST HATCH C/L AK HGL 16.45 18.63 IE IN 16.30 I" " 1 FLOW CONTROL : OF WEIR ' I ' ' RISER 16.28 7 15.20 12'-10"4„ 10'-10" - WATER TABLE7 -3'-8"� 4'-0" PRETREATMENT DISCHARGE 15.20 as CHAMBER CHAMBER 6" 24'-0" _6" 8" 8'-0" 8" 25'-0" 9'-4" ELEVATION VIEW RIGHT END VIEW 1. MANUFACTURER TO PROVIDE ALL MATERIALS UNLESS OTHERWISE NOTED. 2. ALL DIMENSIONS, ELEVATIONS, SPECIFICATIONS AND CAPACITIES ARE SUBJECT TO CHANGE. FOR PROJECT SPECIFIC DRAWINGS DETAILING EXACT DIMENSIONS, WEIGHTS AND ACCESSORIES PLEASE CONTACT MANUFACTURER. IIIIIIIIIIIIIN SYM REVISION BY APPROVED DATE SYM APRON R INFRASTRUCTURE W4700331 ABAM SPT 06/08/18 A CITY OF RENTON COMMENTS W4700331 ABAM SPT 10/01/18 INTERNAL BYPASS DISCLOSURE: THE DESIGN AND CAPACITY OF THE PEAK CONVEYANCE METHOD TO BE REVIEWED AND APPROVED BY THE ENGINEER OF RECORD. HGL(S) AT PEAK FLOW SHALL BE ASSESSED TO ENSURE NO UPSTREAM FLOODING. PEAK HGL AND BYPASS CAPACITY SHOWN ON DRAWING ARE USED FOR GUIDANCE ONLY. LOW INFLOW PIPE DISCLOSURE: IT IS RECOMMENDED THAT A SUFFICIENT VARIATION IN ELEVATION BETWEEN THE INLET AND OUTLET BE PROVIDED TO ALLOW FOR ACCUMULATION OF SEDIMENT IN THE PRE-TREATMENT CHAMBER. FAILURE TO DO SO MAY RESULT IN BLOCKAGE AT INFLOW POINT(S) WHICH MAY CAUSE UPSTREAM FLOODING. PROTECTED BY ONE MORE OF THE FOLLOWING US PATENTS THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE E i C 1�,e� In 7,425,262; 7,470,362; 7,674,378; PROPERTY OF MODULAR WETLANDS SYSTEMS. ANY 8,303,816, RELATED FOREIGN REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PATENTS OR OTHER PATENTS PENDING PERMISSION OF MODULAR WETLANDS SYSTEMS IS PROHIBITED. A FOn'terra Company REVISION TREATMENT FLOW (CFS) 0.20 OPERATING HEAD (FT) 1.0 PRETREATMENT LOADING RATE (GPM/SF) 1.9 INDUSTRIAL MEDIA LOADING RATE (GPM/SF) 1.0 MW54-8-24- V-UG STORM WA TER BIOFIL TRA TION SYSTEM STANDARD DETAIL ri1 LINEAR MODULAR WETLAND SYSTEM RTU-012 C500-38 SCALE: NTS BY I APPROVED I DATE P. of WA I �f ® D BOE//V� � 31271 ISTE NAL AIRCRAFT RATED HATCHES 72" X 36" DOUBLE NEENAH R-3498-R3S 62" X 36" DOUBLE EAST JORDAN 8196-DOUBLE 36" X 36" SINGLE NEENAH R-3498-R2S 24" DIA ROUND NEENAH R-3492 NOTES: 1. ALL VAULT STRUCTURES AND ASSOCIATED ACCESS LIDS AND HATCHES SHALL MEET THE DESIGN LOADING REQUIREMENTS SHOWN ON SHEET G3. 2. THE LIFTING FORCE REQUIRED TO OPEN ACCESS LIDS AND HATCHES SHALL BE A MAXIMUM OF 35-POUNDS. HINGED LIDS AND ACCESS HATCHES SHALL BE EQUIPPED WITH A HYDRAULIC LIFT ASSIST SYSTEM AS REQUIRED TO MEET THE MAXIMUM LIFTING FORCE REQUIREMENTS. 3. MODULAR WETLAND FRAMES, HATCHES, AND LIDS SHALL BE AS SHOWN IN THE TABLE ABOVE OR ENGINEER APPROVED EQUAL. 4. PERMANENT WATER QUALITY TREATMENT FACILITIES SHALL NOT BE USED TO CONVEY OR CONTAIN CONSTRUCTION STORM WATER. NEW FACILITIES SHALL BE KEPT OFFLINE UNTIL PROJECT IS COMPLETE. THE CONTRACTOR SHALL CLEAN AND FLUSH ALL PARTS OF THE SYSTEM PRIOR. SEE GENERAL NOTES ON SHEET G2. 5. SEE STRUCTURAL PLANS FOR STRUCTURAL SUPPORT DETAIL. BergerABAM 33301 9th Avenue South, Suite 300 Federal Way, Washington 98003-2600 (206) 431-2300 Fax:(206) 431-2250 DRAWN DATE SUBTITLE ACCEPTABILITY JDM 06/08/18 THIS DESIGN AND/OR CHECKED SPECIFICATION IS APPROVED SPT 06/08/18 ENGINEER TITLE APPROVED BY DEPT. I DATE BEE 06/08/18 CIVIL MASTE ICIVIL PERMITI STORM DRAINAGE DETAILS - SHEET 8 APRON R INFRASTRUCTURE RENTON SITE R SITE R-401380 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING Fur FACE WATER UTILITY afowler 12/20/2018 +raka 12/20/2018 U wI` \LIV W4700331 J `' /� n 10/01 / 18 SHEET C500-3T C63- JOB NO. COMP NO. W4700331 RENTON, WA DWG NO. 4-APRON-R-0500-3T