Loading...
HomeMy WebLinkAboutR_401386-175 N N 00 N L 0 z E 0 c 0 c� U) m J PIPE CROSSING TABLE SHEET C500-3G CROSSING # PIPE ABOVE BOTTOM ELEVATION PIPE SIZE PIPE CENTER TOP ELEVATION BOTTOM ELEVATION PIPE SIZE PIPE BELOW TOP ELEVATION PIPE SIZE VERTICAL CLEARANCE 1 VERTICAL CLEARANCE 2 OSTORM 13.81 ' 12" - - - - FIRE 12.9 1' 8" .900, - OJOINT TRENCH 15.33' 2"-4" - - - - STORM 14.82' 12" .505' - O3 AIR 16.08' 4" STORM 15.22' 14.12' 12" JOINT TRENCH/WATER 13.62' 2"/4" .865' .510' 4* STORM 14.42' 18" - - - - EX FIRE 14.50' 12" .425' - O5 STORM 14.84' 18" - - - - WATER 14.01' 8" .830, - O6 STORM 14.85' 18" - - - - POWER 13.93' 2" .920' - O7 STORM 14.92' 18" - - - - EX FIRE 14.58' 12" 3.42' - O8 STORM 14.73' 18" - - - - WATER 13.78' 8" .960' - O9 STORM 14.32' 18" - - - - JOINT TRENCH/WATER 13.67' 2"-4" .650' - 10 STORM 13.10' 18" - - - - EX FIRE 12.52' 12" .580' - PIPE CROSSING TABLE SHEET C500-31-1 CROSSING # PIPE ABOVE BOTTOM ELEVATION PIPE SIZE PIPE CENTER TOP ELEVATION BOTTOM ELEVATION PIPE SIZE PIPE BELOW TOP ELEVATION PIPE SIZE VERTICAL CLEARANCE 1 VERTICAL CLEARANCE 2 11 JOINT TRENCH 15.31' 2"-4" - - - - STORM 14.81' 18" .510' - 12* STORM 14.43' 18" - - - - EX FIRE 14.23' 12" .205' - 13 STORM 14.32' 18" - - - - WATER 13.71 ' 8" .605' - 14* JOINT TRENCH 14.05' 2"-12" - - - - STORM 13.57' 36" .480' - 15* STORM 13.77' 12" - - - - EX WATER 13.29' 8" .480' - 16 AIR 15.87' 3" STORM 15.20' 13.57' 18" FIRE/WATER 12.86' 12"/2" .670' .710' PIPE CROSSING TABLE SHEET C500-3J CROSSING # PIPE ABOVE BOTTOM ELEVATION PIPE SIZE PIPE CENTER TOP ELEVATION BOTTOM ELEVATION PIPE SIZE PIPE BELOW TOP ELEVATION PIPE SIZE VERTICAL CLEARANCE 1 VERTICAL CLEARANCE 2 17 STORM 15.21 ' 12" - - - - STORM 14.36' 30" .850' - 18 STORM 11.33' 30" - - - - FIRE 10.35' 12" .980' - 19* AIR 16.02' 3" STORM 15.07' 13.96' 12$$ WATER 13.06' 2" .950' .900, 20 STORM 13.95' 12" - - - - FIRE 13.35' 12" .600' - PIPE CROSSING TABLE SHEET C500-3K CROSSING # PIPE ABOVE BOTTOM ELEVATION PIPE SIZE PIPE CENTER TOP ELEVATION BOTTOM ELEVATION PIPE SIZE PIPE BELOW TOP ELEVATION PIPE SIZE VERTICAL CLEARANCE 1 VERTICAL CLEARANCE 2 21 STORM 14.24' 12" - - - - FIRE 13.51 ' 8" .730' - 22 STORM 13.7' 12" - - - - STORM 12.40' 36$$ 1.300' - 23 STORM 13.55' 12" - - - - FIRE 12.76' 8" .790' - 24* JOINT TRENCH 15.26' 1 "-4" - - - - STORM 14.90' 18" .365' - 25 AIR 16.25' 3" STORM 15.73' 14.17' 18" JOINT TRENCH 13.19' 2"/4" .520' .980' 26 STORM 14.07' 18" - - - - FIRE 13.16' 12" .910, - 27 STORM 14.23' 12" - - - - STORM 12.35' 36" 1.885' - 28 STORM 14.03' 12" - - - - FIRE 12.76' 8" 1.270' - 29 FIRE 13.86' 12" - - - - STORM 12.57' 36" 1.290' - 30 STORM 14.31 ' 12" - - - - STORM 14.45' 36" 1.860' - 31 FIRE 13.83' 12" - - - - STORM 12.42' 36" 1.415' - 32 JOINT TRENCH 15.69' 2"-4" - - - - STORM 12.10' 36" 3.595' - 33 STORM 14.30' 12" - - - - FIRE 13.45' 12" .850' - * CROSSING PIPES HAVE LESS THAN 6" CLEARANCE BETWEEN THEM SEE NOTE 4 ON SHEET C500-313 THROUGH C500-3K. 20 0 20 40 HORZONTAL: scale feet 10 0 10 20 VERTICAL: scale feet i BergerABAM 33301 9th Avenue South, Suite 300 Federal Way, Washington 98003-2600 (206) 431-2300 Fax:(206) 431-2250 CIVIL PERMIT R-401386-1 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING 100111116 Fr12/20/2018 WATER UTILITY afowler 12/20/2018 a Ul SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE UNAWN UAI E SUBTITLE CURRENT REVISION SYMBOL DATE �N P. THIS DESIGN B AND/OR CHECKED 06 08 18 STORM DRAINAGE DETAILS - SHEET 15 W4700331 A 10/01 / 18 APRON R INFRASTRUCTURE W4700331 ABAM SPT 06/08/18 T� SPT 10 01 18 SHEET w of WAsx�� G SPECIFICATION IS APPROVED A CITY OF RENTON COMMENTS W4700331 ABAM SPT � 10 01 18 ® ���� ENGINEER TITLE APRON R INFRASTRUCTURE / / APPROVED BY DEPT. DATE BEE 06 08 18 CHECKED /--�A ��0O_� nC70 L APPROVED AL RENTON SITE �o R 31271 o ww JOB N0. COMP N0. ss�oN�W4700331 APPROVED CIVIL MASTER SITE RENTON, WA DWG NO. 4-APRON-R-0500-3AA