HomeMy WebLinkAboutR_4013198I*] N �5 � a � V,28A/ 11 (4)4 C,- 3#600, #2/OGND II E510-1�113 HARDSTAND R4 • MATCH LINE, SEE SHEET E114 5 R4-1/3 \� \\ 1 "C, 2# 12 \ R4/19,21,23 \� \ 1 "C, 3#10, #10 GND 3 i 0 \ I OWS-066 I I x I I I I �- I I -� TEMP I ° STRUCT I I I I I I *eA j 200' SHORELINE SETBACK •PER CITY OF RENTON F- I CTUATOR VALVE I V-1099-18 0 I - I I I I I I I I � o i I 0 I I • I • • I I I I I 0 I _ I I I 0 I MATCH LINE, SEE SHEET E112 PARTIAL POWER PLAN SCALE: 1 "=20'-O" 0 Ill I� Q J � Q Q CD Q m � z o �O O w 1:1 0 m 0 0 w 0 0 o m o m m HARDSTAND omomomom 9 IJ 0 O 0 0 20 10 0 10 20 40 SCALE: IN FEET LEGEND Oo 480V, 3� MOTOR/VALVE (SIZE AS NOTED) GENERAL NOTES o 1. NO EXPOSED GALVANIZED STEEL TO BE INSTALLED C ABOVE GRADE ON APRON. PVC COATED OR PAINTED RIGID STEEL IS ACCEPTABLE. C 2. COLOR CODING OF CONDUCTORS SHALL BE OBSERVED p ON ALL CIRCUITS 600 VOLTS OR LESS AS FOLLOWS: T OV 3. "A" PHASE (LEFT BUS IN PANEL) BROWN "B" PHASE (CENTER BUS IN PANEL) ORANGE 'C" PHASE (RIGHT BUS IN PANEL) YELLOW NEUTRAL GRAY EQUIPMENT GROUND GREEN 4. FOR UNDERGROUND CONDUIT ELBOWS AND FITTINGS, CURVES LESS THAN FIVE FOOT IN RADIUS, ELECTRICAL ELLS, BENDS, AND SWEEPS SHALL BE PVC COATED GALVANIZED RIGID STEEL. STRAIGHT SECTIONS AND CURVES WITH LARGER THAN FIVE FOOT RADIUS MAY BE SCHEDULE 40 PVC. 5. UNLESS OTHERWISE SHOWN, PITCH CONDUIT AT 1 MINIMUM SLOPE TOWARDS MANHOLES. 6. A RED PLASTIC WARNING TAPE, POLYETHYLENE, 24 INCHES WIDE, WITH 4.0 MIL THICKNESS, AND CONTINUEING THE ENTIRE LENGTH OF THE cy UNDERGROUND CONDUITS, SHALL BE INSTALLED AT C LEAST SIX INCHES ABOVE BURIED CONDUIT AND NOT C SHALLOWER THAN ONE FOOT DEEP. TAPE SHALL BE CONTINUESLY IMPRINTED "CAUTION: BURIED rN ELECTRICAL LINE BELOW" G 7. HORIZONTAL DATUM: WASHINGTON STATE COORDINATE -_ SYSTEM, NORTH ZONE, NORTH AMERICAN DATUM 1983(91). VERTICAL DATUM: NATIONAL GEODETIC VERTICAL DATUM 1929 (NGVD29). VERTICAL DATUM CONVERSION: NGVD29 TO THE NORTH AMERICAN VERTICAL DATUM 1988 (NAVD88) = NGVD29 + 3.60 FEET. CONSTRUCTION NOTES PROVIDE AND INSTALL EQUIPMENT HARDSTAND AS SHOWN ON DETAIL DRAWINGS E510-10 THROUGH E510-17. PROVIDE AND INSTALL BURIED CONDUIT, CONDUCTORS AND ALL ANCILLIARY HARDWARE. PROVIDE AND INSTALL BURIED CONDUIT AND CONDUCTORS FOR OWS ACTUATOR VALVE. ® PROVIDE (3) 3/4" X 30' COPPER CLAD GROUND RODS AND STATIC GROUND WELL RECEPTACLES PER c PLANE POSITION. CONTRACTOR TO COORDINATE WITH T BOEING'S PRIME POWER GROUP FOR FINAL TESTING. C PROVIDE PRECAST 11 "X18"X12" OPEN BOTTOM C HANDHOLE WITH TRAFFIC RATED, HEX BOLTED LID. r OLDCASTLE PART #1118-12 OR APPROVED EQUAL. T a IFFY PI AN a LAKE WASHINGTON SCALE: N.T.S. F-- CCASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW. CA SNE. COM JOB NO. 161-140 CIVIL PERMIT % =====No SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE C4 UKAWN UAIt SUBTITLE CURRENT REVISION SYMBOL DATE A APRON R INFRASTRUCTURE W4700331 CASNE CEC 06.08.18 wash j �� THIS C DACEESIGN TAB05.05.17 W4700331 A 06.08.18 AND/OR CHECKED �' ��� DAT 05.05.17 PARTIAL POWER PLAN SHEET SPECIFICATION IS APPROVED VED BY DEPT. DATE DATINEER 05.05.17 TITLE APRON R INFRASTRUCTURE El 13 E30 CHECKED °� 35276 w� APPROVED RENTON SITE JOB NO. COMP NO. �S��� �' I 10is � 8ll APPROVED DWG NO. W4700331 ]ELECTRICAL MASTER SITE RENTON, WA RTN-YD-El13