Loading...
HomeMy WebLinkAboutR_4013200SYM A I APRON R INFRASTRUCTURE I:a MInil BY APPROVED W47003311 CASNE CEC DATE I SYM 1. 1: MATCH LINE, SEE SHEET E114 PARTIAL SCALE: 1 "=20'-0 POWER PLAN Q� BOE/NG C'- ��� of WAS L�T� NG 20 10 0 10 20 40 SCALE: IN FEET ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED - UNAWN HGG UAIL 05.05.17 SUBTITLE CHECKED DAT 05.05.17 ENGINEERTITLE DAT 05.05.17 ; ,PROVED BY DEPT. I DATE PARTIAL POWER PLAN APRON R INFRASTRUCTURE LEGEND Qo 480V, 3� MOTOR/VALVE (SIZE AS NOTED) GENERAL NOTES a 1. NO EXPOSED GALVANIZED STEEL TO BE INSTALLED c ABOVE GRADE ON APRON. PVC COATED OR PAINTED RIGID STEEL IS ACCEPTABLE. 2. COLOR CODING OF CONDUCTORS SHALL BE OBSERVED O ON ALL CIRCUITS 600 VOLTS OR LESS AS FOLLOWS: 277 480V T 3. "A" PHASE (LEFT BUS IN PANEL) BROWN "B" PHASE (CENTER BUS IN PANEL) ORANGE "C" PHASE (RIGHT BUS IN PANEL) YELLOW NEUTRAL GRAY EQUIPMENT GROUND GREEN 4. FOR UNDERGROUND CONDUIT ELBOWS AND FITTINGS, CURVES LESS THAN FIVE FOOT IN RADIUS, ELECTRICAL ELLS, BENDS, AND SWEEPS SHALL BE PVC COATED GALVANIZED RIGID STEEL. STRAIGHT SECTIONS AND CURVES WITH LARGER THAN FIVE FOOT RADIUS MAY BE SCHEDULE 40 PVC. 61 A 7 UNLESS OTHERWISE SHOWN, PITCH CONDUIT AT 1 MINIMUM SLOPE TOWARDS MANHOLES. A RED PLASTIC WARNING TAPE, POLYETHYLENE, 24 INCHES WIDE, WITH 4.0 MIL THICKNESS, AND CONTINUEING THE ENTIRE LENGTH OF THE T UNDERGROUND CONDUITS, SHALL BE INSTALLED AT CY LEAST SIX INCHES ABOVE BURIED CONDUIT AND NOT C SHALLOWER THAN ONE FOOT DEEP. TAPE SHALL BE CC CONTINUESLY IMPRINTED "CAUTION: BURIED I ELECTRICAL LINE BELOW" r T HORIZONTAL DATUM: WASHINGTON STATE COORDINATE G SYSTEM, NORTH ZONE, NORTH AMERICAN DATUM —_ 1983(91). VERTICAL DATUM: NATIONAL GEODETIC VERTICAL DATUM 1929 (NGVD29). VERTICAL DATUM CONVERSION: NGVD29 TO THE NORTH AMERICAN VERTICAL DATUM 1988 (NAVD88) = NGVD29 + 3.60 FEET. CONSTRUCTION NOTES PROVIDE AND INSTALL EQUIPMENT HARDSTAND AS SHOWN ON DETAIL DRAWINGS E510-10 THROUGH E510-17. PROVIDE AND INSTALL BURIED CONDUIT, CONDUCTORS AND ALL ANCILLIARY HARDWARE. PROVIDE AND INSTALL BURIED CONDUIT AND CONDUCTORS FOR OWS ACTUATOR VALVE. ®PROVIDE (3) 3/4" X 30' COPPER CLAD GROUND RODS AND STATIC GROUND WELL RECEPTACLES PER PLANE POSITION. CONTRACTOR TO COORDINATE WITH BOEING'S PRIME POWER GROUP FOR FINAL TESTING. C T PROVIDE AND INSTALL BURIED CONDUIT AND C CONDUCTORS FROM TURNSTYLE CONTROL BOX TO C OUTSIDE OF 04-83 BUILDING. C IN ©PROVIDE AND INSTALL UNDERGROUND FEED TO T CATHODIC PROTECTION SYSTEM RECTIFIER. ROUTE FEEEa AROUND UTILITY STUB UPS. p KEY PLAN SCALE: N.T.S. LAKE WASHINGTON O CCASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW. CA SNE. COM JOB NO. 161-140 CIVIL PERMIT W4700331 J I tVIUVL n ""' L 06.08.18 El 15 E32 JOB NO. COMP NO. W4700331 J r 35276 ��Z1 STER�� �SSIONAL� ELECTRICAL MASTER RENTON SITE SITE RENTON, WA I III NO. RTN-YD-El15