HomeMy WebLinkAboutR_4013201MATCH LINE. SEE SHEET E361 1 10 1 10 20 '1 �. /- %) SCALE: IN FEET i� GENERAL NOTES 1. NO EXPOSED GALVANIZED STEEL TO BE INSTALLED ABOVE GRADE ON APRON. PVC COATED OR PAINTED RIGID STEEL IS ACCEPTABLE. 2. UNDERGROUND STRAIGHT SECTIONS OF CONDUITS SHALL BE CONSTRUCTED OF RIGID NONMETALLIC SCHEDULE 40 PVC. 3. UNDERGROUND DISTRIBUTION CONDUITS SHALL BE TRADE SIZE 4 OR 4" CONDUITS UNLESS NOTED OTHERWISE ON DRAWINGS. 4. UNDERGROUND CONDUITS SHALL BE INSTALLED A MINIMUM OF 36" BELOW GRADE. 5. CONDUIT SWEEPS SHALL BE CONSTRUCTED OF RIGID STEEL (PVC COATED IF UNDERGROUND) WITH A MINIMUM 48" BEND RADIUS. 6. UNDERGROUND CONDUITS SHALL HAVE 3/8" DIAMETER NYLON PULLING TAPE, ROPE, OR STRAP, WITH A TENSILE RATING EXCEEDING 2500 LBS INSTALLED. PULLING TAPE SHALL HAVE 36" TAILS, SECURED AT EACH END OF CONDUIT. 7. UNDERGROUND DATA CONDUITS SHALL BE SPACED A MINIMUM OF 12" AWAY FROM ELECTRICAL CONDUITS. THIS ALSO INCLUDES GAS, OIL, OR WATER PIPING. MINIMUM SPACING IS REDUCED TO 3" WHEN NG EMBEDDED IN CONCRETE. 8. CONDUIT PENETRATIONS IN HANDHOLES SHALL BE INSTALLED WITH SCHEDULE 40 PVC BELL ENDS. 9. CONTRACTOR TO COORDINATE INSTALLATION OF DATA/TELECOM PATHWAY, PRIOR TO INSTALLATION, WITH BOEING'S CONTRACTED I.T. INSTALLER. 10. NO SECTION OF UNDERGROUND CONDUIT SHALL EXCEED 600 FEET BETWEEN PULLING POINTS WITH NO MORE THAN 180 DEGREES IN CONDUIT BENDS. 11. HORIZONTAL DATUM: WASHINGTON STATE COORDINATE SYSTEM, NORTH ZONE, NORTH AMERICAN DATUM 1983(91). VERTICAL DATUM: NATIONAL GEODETIC VERTICAL DATUM 1929 (NGVD29). VERTICAL DATUM CONVERSION: NGVD29 TO THE NORTH AMERICAN VERTICAL DATUM 1988 (NAVD88) = NGVD29 + 3.60 FEET. CONSTRUCTION NOTES PROVIDE 12"x12"x6" NEMA 4X SS, DATA PULL BOX ON EQUIPMENT HARDSTAND. PROVIDE BURIED CONDUIT WITH NYLON PULL STRING. KEY PLAN SCALE: N.T.S. LAKE WASHINGTON L CCASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW. CA SNE. COM JOB NO. 161-140 CIVIL PERMIT SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE C4 UKAWN UAIt SUBTITLE CURRENT REVISION SYMBOL DATE A APRON R INFRASTRUCTURE W4700331 CASNE CEC 06.08.18 wash j �� THIS DESIGN BAND/ R CHECKED 05.05.17 W4700331 A 06.08.18 �, �.�ILITY PARTIAL DATA PLAN SPECIFICATION IS APPROVED DAT 05.05.17 SHEET VIED BY DEPT. DATE DATINEER 05.05.17 TITLE APRON R INFRASTRUCTURE E360 E33 CHECKED "d,p 35276 w� APPROVED RENT 0 N SITE JOB N0. COMP N0. 0 rsTER� ' W4700331 �SSIONAL�� 8ll APPROVED ]ELECTRICAL MASTER SITE RENTON, WA DWG No. 04-APRON-R-E360 0 C C� C' C C 0 T A T y � `' a C C T 4