HomeMy WebLinkAboutR_4013211n5
4.5
n4
3.5
n3
F-i
1
561-A1
i PNL UQ3.5
PNL UQ4
Q
5
2XQ8 — 1-1/2"C 03.5
03
3)3-1/2"C, 4#600KCMILLj
2 OGND
19KiKGONDIlNDUI
2Q3.5
0. PNL 2Q3.5—(3)3-1/I
VAULT VAULT
V28A 1 V28B
3
250KCMIL X
C#2/OGND
3 C, 4 500KCMIL B
;�
;(2
"C, 4#600K
IL
600KCMIL
PNL X203
F
C
L
FC—PNL2Q4-1
24FLA,2PNL
#2/OGN
PNL 2Q3.5-2
300
KVA
XFMR
EBROKO
1
0-01
#10,s
0
A
MR
K 2Q3.5-2/1
it L)
L]
2R3
O 0
o0 0
O
❑❑
MCC#1
3 —
3/4"C F E h
El
2Q3.5-2-7,9,1
Oo
w
5 R4.75 R
.5 R4.25 F
4 H 1 R
5HP, 48OV, 3PH
HWP-2
5HP, 480V 3PH
5
SYM
REVISION
BY
APPROVED
DATE
SYM
A
4-81 /82 UNIT SUB REPLACEMENT W3045112
CASNE
RJJ
12.30.16
B
4-81-82 BUS DUCT PANEL REPLACEMENT 33268
CASNE
RJJ
06.23.17
C
APRON R INFRASTRUCTURE W4700331
CASNE
CEC
06.08.18
CWklwill
BY I APPROVED I DATE
PARTIAL FLOOR PLAN
SCALE: 1 /8"=1 ' - 0"
�4* of waste L��
352 6 w�
40 � 1 STER�
�SSIONAL� „P
3Q
C
R
ACCEPTABILITY J ANDRE JAI
112.16.11 SUBTITLE PARTIAL LEVEL TWO
THIS DESIGN AND/OR CHECKED 480Y/277V POWER PLAN
SPECIFICATION IS APPROVED
ENGINEER TITLE APRON R INFRASTRUCTURE
',f2RDVED BY DEPT. DATE
BUILDING 04-81-82
30
GENERAL
277/480V PANEL
120/208V PANEL
480V MOTOR (SIZE AS NOTED) 0
MOTOR STARTER
C'
DISCONECT
C
C
480V RECEPTACLES
0
T
JUNCTION BOX
C
NOTES
1. ALL DROPS AND RECEPTACLES TO BE PER BOEING
STANDARD DRAWINGS.
2. ALL WIRE TO BE #12, TYPE THW, OR THHN, AND
ALL CONDUIT TO BE 1 /2" TYPE EMT, UNLESS
OTHERWISE NOTED.
3. ALL CONDUIT RUN ON THE FLOOR, IN CHASES, OR
SUBJECT TO PHYSICAL DAMAGE OR MOISTURE TO BE
RIGID STEEL.
4. ALL CONDUIT RUN ON THE FLOOR TO BE COVERED
WITH MASTIC.
5. ALL WIRE TO BE COPPER UNLESS OTHERWISE NOTED.
I
VA
ALL FLEXIBLE CONDUIT SHALL INCLUDE A GROUNDINCT
JUMPER SIZED AS NOTED TO INSURE GROUNDING CY
CONTINUITY. a
COLOR CODING FOR NEW OR EXTENDED 480 VOLT C
CIRCUITS SHALL BE: I
I
rN
"A"
PHASE
(LEFT BUS IN
PANEL)
BROWN G
"B"
PHASE
(CENTER BUS
IN PANEL)
ORANGE —
"C"
PHASE
(RIGHT BUS IN
PANEL)
YELLOW
NEUTRAL GRAY
REFERENCE DRAWINGS
1 E-3-11 PARTIAL/LEVEL 1 480/277V PLAN
E4H-V28A ONE -LINE DIAGRAM SUB V28A
E4H-E28B ONE -LINE DIAGRAM SUB V28B
CONSTRUCT ON NOTES
USE EXISTING SLEEVES FOR (2) 4" CONDUITS IN
LEVEL 2 FLOOR. COORDINATE CORE DRILL LOCATION
WITH LEVEL 1 CONDUIT STUB UPS SHOWN ON
1 E-3-44. LOCATE AND AVOID DAMAGING EXISTING
REINFORCEMENT. PROVIDE CABLE TERMINATIONS AND
LAND CONDUCTORS ON V28B BREAKER 5.
LEVEL yox
LEVEL 9
LEVEL 8
a�a�
7
LEVEL 6
0
LEVEL 5
0
LEVEL 4
KEY SECTION
SCALE: NONE
12 11 C9� M C M M
T
T
—
14
13
12
11
10
19
18
17
16
15
24
23
22
21
20
30
1 29
28
27
26
25
36
35
34
33
32
31
42
41
40
39
38
37
48
47
46
45
43
KEY PLAN
NONE \
CCASNE ENGINEERING, INC.
ELECTRICAL AND TECHNOLOGY CONSULTANTS
10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033
(425) 522-1000 WWW. CA SNE. COM JOB NO. 161-140
CIVIL PERMIT
CURRENT REVISION ISYMBOL DATE
W47003311 C 06.08.18
SHEET
2E-3-44 E43
JOB No. COMP N0.
W4700331 XX
DWG IN
RENTON, WA 04-81-82-2E-3-44
c
T
u
c
c
c
r
T
a
0
D
D
D
D
D
D
D
ELECTRICAL MASTER
COL 5-7/A-B