Loading...
HomeMy WebLinkAboutR_4013161C'M 0 i O i w lei co N N co CD u; 0 z 0 0 ca J 4), Ber erABAM CALL 48 HOURS BEFORE YOU DIG 33301 9th Avenue South, Suite 300 Federal Way, Washington 98003-2600 1-800-424-5555 (206) 431-2300 Fax: (206) 431-2250 SYM REVISION BY APPROVED DATE SYM - APRON R INFRASTRUCTURE W4700331 ABAM I MGW 06/08/18 REVISION MATCH LINE, SEE SHEET M265 BY I APPROVED I DATE MATCH LINE, SEE SHEET M263 P. of WAsh� �f x 31271 w� ��ssioNaL 1 10 1 10 20 40 ��, 11� _1• FBI SCALE: IN FEET %/i UNAWN UAI L SUBTITLE ACCEPTABILITY JLC 06/08/18 THIS DESIGN AND/OR CHECKED SPECIFICATION IS APPROVED SPT 06/08/18 ENGINEER TITLE APPROVED BY DEPT. I DATE JLC 06/08/18 GENERAL NOTES 1. SEE SHEET G02 FOR FIRE AND WATER SERVICE NOTES. 2. ALL FIRE LINE SHALL BE INSTALLED WITH RESTRAINED JOINTS. 3. SEE SHEET M510-2 DETAIL 3 FOR TYPICAL UTILITY TRENCH BEDDING AND BACKFILL. 4. SEE SHEET M510-2 DETAIL 5 FOR JOINT UTILITY TRENCH. 5. COORDINATE ALL DOMESTIC WATER AND FIRE WATER SHUT DOWNS REQUIRED FOR CONNECTIONS TO EXISTING WITH BOEING SITE SERVICES AND FIRE DEPARTMENT. 6. FITTINGS SHOWN FOR CONNECTIONS TO EXISTING ARE SUGGESTED. CONTRACTOR SHALL POTHOLE AND FIELD VERIFY PIPE TYPE, LOCATION, CONDITION AND ROUNDNESS PRIOR TO ORDERING MATERIALS. 7. HORIZONTAL CONTROL NOTES SHOWN ON THIS SHEET REPRESENT CENTER OF STRUCTURE, BEND OR CENTERLINE OF PIPE. 8. SEE SHEETS C80-C81 AND C500-56 FOR HARDSTAND CLEARANCES. 9. HORIZONTAL DATUM: WASHINGTON STATE COORDINATE SYSTEM, NORTH ZONE, NORTH AMERICAN DATUM 1983(91). VERTICAL DATUM: NATIONAL GEODETIC VERTICAL DATUM 1929 (NGVD29). VERTICAL DATUM CONVERSION: NGVD29 TO THE NORTH AMERICAN VERTICAL DATUM 1988 (NAVD88) = NGVD29 + 3.60 FEET. 1 FIRE HYDRANT ASSEMBLY M510-2 2� WATER SERVICE AND AIR VAULT 1 - 2"x2" TEE M510-3 2 - 2" VALVES REFER TO MECHANICAL PLANS FOR CONTINUATION 3 PIV SECTION VALVE 1I M510-2 CONSTRUCTION NOTES 1- 2" 22.5° BEND 2� CONNECT TO EXISTING 2" COPPER LINE IN VAULT 1 - 2" VALVE 1 - 2" ADAPTER B� 1- 2" 45° BEND PIPE DEFLECTION 1 - 12" 45° BEND (RJ) 1 - 12" TEE (FL) 2 - 12" PIV (FL) 3 - 12" COUPLING ADAPTER (FL x RJ) 1 - 12"x6" TEE (FL) 1 - 6" GATE VALVE (FL) 1 - 6" COUPLING ADAPTER (FL x RJ) 2 - 12" COUPLING ADAPTER (FL x RJ) 1 - 12" 22.5° BEND (RJ) 12" FIRE LINE PIPE DEFLECTION 10 1 - 12" 11.25° BEND (RJ) 11 CONNECT TO EXISTING 10" FIRE MAIN 1 - 10" RESTRAINED COUPLING 1 - 10" SPOOL AS REQUIRED (FL) 1 - 10"02" REDUCER (FL) 1 - 12" COUPLING ADAPTER (FL x RJ) SEPARATE FIRE PERMITS REQUIRED FROM RENTON REGIONAL FIRE AUTHORITY CIVIL PERMIT FIRE PROTECTION AND WATER - SHEET 5 KEY PLAN SCALE: N.T.S. W-401306 R-4013161 IN COMPLIANCE WITH CITY OF RENTON STANDARDS N►1f10l1xxsl 06/08/18 APRON R INFRASTRUCTURE M264 M18 RENTON SITE JOB NO. COMP NO. W4700331 SITE RENTON, WA DWG NO. 4—APRON—R—M264 CIVIL MASTER