HomeMy WebLinkAboutR_401316575
o_
N
N_
00
0
N
u;
0
z
0
0
ca
M
J
i
Full 180° Open
—I—I—I—I—I—I—I—I—
�
—I—I—I—I—I—I—I—I—I—I—I—I—
�� � � —I—I—I—I—I—I—I—I—I—I—I—I—I—
�� � I —I —I —I —I —I —I —I —I —I —I —I —I —I —I-
-I —I —I —I —I —I —I —I —I —I —I —I —I —I —I —I -
Cover
No. 3030-P
110 lbs.
Optional Solid Base
No. 3030-SB
950 lbs.
NOTES:
1. ALL VAULTS AND JUNCTION BOXES SHALL MEET THE LOAD RATING SPECIFIED
ON SHEET G2.
2. FRAME AND GRATE SHALL BE NEENAH FOUNDRY PRODUCT R-3498-K2S OR
APPROVED SIMILAR. COORDINATE FRAME AND GRATE DETAILS WITH
MANUFACTURER BEFORE FABRICATION OF VAULTS.
3. THE BASE SHALL CONTAIN (2) - 3" MIN. DIAMETER HOLES TO ALLOW FOR
DRAINAGE.
i BeraerABAM
CALL 48 HOURS
BEFORE YOU DIG 33301 9th Avenue South, Suite 300
Federal Way, Washington 98003-2600
1-800-424-5555 (206) 431-2300 Fax: (206) 431-2250
SYM REVISION
- APRON R INFRASTRUCTURE W4700331
11„
2
2'-4„
2'-6"
N
`-r) i / /- Ulu. uvi Lo
For Frame Hold -Down
PLAN VIEW
SIN
Cover Not Shown
2'-08„
5 Dic. Knockouts o
2 Each Side, 4 Sides I I
N
1„61>, I 41„
2 8 2
FRONT VIEW SIN
2'-O8"
5 Dia. Knockouts
2 Each Side, 4 Sides
L
_ I _ d 2„ 68„
1'-112»
FRONT VIEW
Shown With Optional Solid Base
T2
LGalvanized Diamond Plate Cover
w/ Locking Latch
PLAN VIEW
-Dnown min l-over
2'-08„
O
Lift Hole
1 1 /2" Dia.
I
1'-112"
SIDE VIEW
2'-O8"
Lift Hole
1 1 /2" Dia.
— 1'-112„ —
SIDE VIEW
Shown With Optional Solid Base
DOMESTIC WATER AND COMPRESSED AIR VANE AND TEE VAULT
M261 SCALE: NTS
THRU
M265
BY I APPROVED I DATE
ABAM I MGW 06/08/18
SYM
REVISION
BY I APPROVED I DATE
P.
of WA �f
® D
""A//V" �P �1
x
31271 w�
��ssioNaL
ACCEPTABILITY IJLC
THIS DESIGN AND/OR CHE
SPECIFICATION IS APPROVED SPT
ENG
APPROVED BY DEPT. I DATE JLC
LU
i
2
II
0 I
w
I
M261
)AIL SUBTITLE
06/08/18
06/08/18
06/08/18 TITLE
CW -
I C(`CNIFI
INSULATED UTILITY. INSULATION AND HEAT TRACE
WIRE TO MATCH EXISTING ABOVE GROUND
DOMESTIC WATER UTILITY.
REMOVE ABOVE GROUND UTILITY
UNDERGROUND LIMITS
CONSTRUCTION NOTES
1� WATER AND AIR UTILITY VAULT
2� PRESSURE REDUCING VALVE
3� PROVIDE TEMPORARY ECO BLOCK WALL
4� REMOVE CONCRETE BARRIER SECTION
5� CUT -IN -TEE TO EXISTING DOMESTIC WATER LINE
WATER VALVE
7� CAP EXISTING DOMESTIC WATER
[:
cW W
— — — — — — — — —
-
I
I
I
I
I
J
�
LL
A ---
I
I
I
I
�
--- A--.--
I
I
I
A--- A
A-
TEMPORARY WATER LINE DETAILS
SCALE: NTS
CIVIL MASTER
SEPARATE FIRE PERMITS REQUIRED FROM RENTON
REGIONAL FIRE AUTHORITY
CIVIL PERMIT,
MECHANICAL DETAILS - SHEET 2
APRON R INFRASTRUCTURE
RENTON SITE
SITE
R-4013165
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
W4700331 — 06/08/18
SHEET
M510-3 M22.
JOB NO. COMP NO.
W4700331
RENTON, WA DWG No. 4—APRON—R—M510-3