HomeMy WebLinkAboutR_40131683 v 0 w I Of I Z 0 Of Q I 0 .3 0 0 i 0 a Of c 0 a Q V) I 0 m E 0 Q m 0 i U N 0 L IL w CD J 00 a; M N PLAN SYMBOLS POWER ® PANELBOARD, 480Y/277V, 3 PHASE 0 PANELBOARD, 208Y/12OV, 3 PHASE e EQUIPMENT IDENTIFICATION 'Y' DENOTES EQUIPMENT NUMBER "Y" DENOTES HP OR KW RATING © ENCLOSED CIRCUIT BREAKER ❑-I DISCONNECT SWITCH, NON -FUSIBLE OJ DISCONNECT SWITCH, FUSIBLE Z' MOTOR STARTER (COMBINATION) ❑T OR TRANSFORMER (SIZE AS SHOWN, IN KVA) J@OR J❑ JUNCTION BOX O 460 VOLT MOTOR (SIZE AS NOTED) 115 VOLT MOTOR (SIZE AS NOTED) 0 TELEPHONE/POWER POLE 20A, 120V, 1 PHASE, DUPLEX, HUBBELL 5262 (2) 20 DUPLEX RECEPTACLES, HUBBELL 5262 ® EQUIPMENT CONNECTION (AS NOTED) CONDUIT NOT BURIED BURIED CONDUIT WIRING (UNDERGROUND & IN FLOOR SLAB) CONDUIT, UNDER RAISED FLOOR FLEXIBLE METAL CONDUIT INDICATES PHASE CONDUCTOR (SIZE AS NOTED) INDICATES NEUTRAL CONDUCTOR INDICATES GROUND CONDUCTOR INDICATES ISOLATED GREEN GROUND CONDUCTOR CIRCUIT SOURCE PANEL/(2P OR 3P CKT), 1 P CKT 1 D6-1 /(1,3,5),7 CONDUIT TURNS DOWN CONDUIT TURNS UP CONDUIT ONLY C.O. E EMERGENCY CIRCUIT COMMUNICATIONS 1 TELEPHONE OUTLET SZ DATA OUTLET I VOICE/DATA OUTLET LIGHTING ® 1' X 4' SURFACE FLUORESCENT LUMINAIRE ® CLASS 1, DIV 1, EXPLOSION PROOF, COPPER FREE ALUMINUM HOUSING, STAINLESS STEEL HARDWARE, HIGH IMPACT RESISTANT TEMPERED BOROSILLICATE GLASS GLOBES, ADJUSTABLE ALUMINUM SURFACE MOUNTING BRACKETS. 0 4' STRIP FLUORESCENT LUMINAIRE, COLD ROLLED STEEL HOUSING, BAKED WHITE ENAMEL FINISH, WIRE GUARDS FULL -CUTOFF WALL MOUNTED LUMINAIRE, DIE-CAST ALUMINUM HOUSING, WET LOCATION LISTED, PREMIUM POLYESTER POWDER COAT PAINT FINISH IN BRONZE 00 LIGHT FIXTURE - FLUORESCENT WITH ALL BALLASTS ON EMERGENCY CIRCUIT SELF CONTAINED, WALL MOUNTED EMERGENCY LIGHTING UNIT �+ EXIT SIGN, WALL MOUNTED ®+ EXIT SIGN, CEILING MOUNTED FIXTURE IDENTIFICATION e 'Y' DENOTES FIXTURE TYPE "ZZ" DENOTES FIXTURE WATTAGE $, $3, $4 TOGGLE SWITCHES - LINE VOLTAGE, SINGLE POLE/ 3-WAY/ 4-WAY NUMBER OF SWITCHES UNDER COMMON PLATE AS INDICATED. $Lv, 2$Lv, , 4$Lv LOW -VOLTAGE LIGHTING CONTROL SWITCHES. NUMBER OF SWITCHES UNDER COMMON PLATE AS INDICATED. LV LOW -VOLTAGE LIGHTING CONTROL WIRING. 3/C #18 AWG IN 1/2"C UNLESS OTHERWISE NOTED. DIAGRAM SYMBOLS SINGLE LINE uiu TRANSFORMER (DASHED LINE INDICATES ELECTROSTATIC ffm SHIELD) i FUSED SWITCH I/ DISCONNECT SWITCH f IDIO—I 600 A M.L.O. 3 PH, 3 W IDIO-2 225 A M. BKR, 3 PH, 4W PANELBOARDS Di DISCONNECT SWITCH GROUNDING GROUND CABLE (UNDERGROUND) & CABLE CONNECTION POTENTIAL TRANSFORMER GROUND ROD CONNECTION 2 480:120 QUANTITY & RATIO AS SHOWN GROUND CABLE PIGTAIL CURRENT TRANSFORMER G GROUND CONDUCTOR IN CONDUIT 3 800:5 QUANTITY & RATIO AS SHOWN INTERLOCK FIRE ALARM K K=KEY M=MECHANICAL E=ELECTRICAL 4 MANUAL PULL STATION q AS AMMETER w/SWITCH Ts FIRE SPRINKLER TAMPER SWITCH Fs FIRE SPRINKLER FLOW SWITCH V VS VOLTMETER w/SWITCH Ps FIRE SPRINKLER PRESSURE SWITCH WHM WATTHOUR METER SYM I REVISION BY APPROVED DATE SYM REVISION — APRON R INFRASTRUCTURE W47003311 CASNE CEC 06.08.18 GENERAL DEMOLITION NOTES GENERAL CONSTRUCTION NOTES 1. ALL CONDUIT SCHEDULED FOR DEMOLITION SHALL BE COMPLETELY REMOVED BACK TO A. WORK INCLUDED: FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND TOOLS FOR THE SOURCE OR NEAREST ACCESSIBLE JUNCTION BOX. WIRING SCHEDULED FOR COMPLETION OF ALL ELECTRICAL SYSTEMS AND RELATED WORK AS INDICATED ON THE p DEMOLITION SHALL BE REMOVED BACK TO SOURCE. SCHEDULED TO REMAIN CONDUIT DRAWINGS. C STUB UPS SHALL BE CUT OFF AND PLUGGED FLUSH WITH SLAB SURFACE UNLESS OTHERWISE NOTED. B. CODES AND ORDINANCES: ALL WORK SHALL COMPLY WITH LOCAL ORDINANCES, AND C� SHALL CONFORM TO THE NEC. c 2. COORDINATE DISPOSITION OF REMOVED MATERIALS AND EQUIPMENT WITH THE BOEING Q REPRESENTATIVE. COPPER AND OTHER METALS SHALL BE SALVAGED TO BOEING. C. RECORD DRAWINGS: MAINTAIN UP TO DATE "AS -BUILT" DRAWINGS ON SITE AT ALL T PLACE MATERIALS IN CONTAINERS PROVIDED BY BOEING. TIMES. CLEARLY INDICATE ON THESE DRAWINGS, IN RED PENCIL, THE LOCATIONS OF ALL CONCEALED AND UNDERGROUND CONDUIT, AND ALL DEVIATIONS TO THE CONTRACT 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DE -ENERGIZING ANY CIRCUITS OR DRAWINGS. EQUIPMENT REQUIRED FOR THIS DEMOLITION WORK. D. CIRCUIT BREAKERS INSTALLED IN EXISTING PANEL BOARDS: THE SAME MANUFACTURER 4. COORDINATE AND SCHEDULE WITH BOEING ANY POWER SHUT DOWNS REQUIRED BY AND FRAME TYPE AS THOSE REQUIRED FOR THE EXISTING PANELBOARDS. AIC RATINGS THIS DEMOLITION WORK. ENSURE THAT ADEQUATE TEMPORARY AND/OR REROUTING OF AND FRAME TYPES SHALL BE AS INDICATED ON DRAWING OR IN PANEL SCHEDULES. SERVICES ARE APPROVED TO AREAS NOT PART OF THIS DEMOLITION WORK, BUT WHICH ARE ADJACENT TO THE AREA(S) OF WORK AND WHICH WOULD BE AFFECTED BY A H. CIRCUIT IDENTIFICATION SHUT DOWN. THE CONTRACTOR SHALL FOLLOW THE BOEING STANDARD LOCKOUT/TAG 1. PROVIDE SELF-ADHESIVE LABELS ON INTERIOR 120V RECEPTACLES, 120V & 277V OUT (LOTTO) PROCEDURES THROUGHOUT ANY REQUIRED SHUT DOWN, DEMOLITION LIGHT SWITCHES, DEVICES, BOXES AND JUNCTION BOXES, 480V RECEPTACLES, AND AND/OR TEMPORARY RECONNECTION PROCESS. DISCONNECT SWITCHES. LABELS SHALL BE 3/8 INCH, WHITE LETTERS ON BLACK BACKGROUND. 5. REMOVAL AND DISPOSAL OF ALL IDENTIFIED HAZARDOUS MATERIALS SHALL BE 2. PROVIDE NAMEPLATES ON ALL PANEL BOARDS, CONTROL PANELS, ETC., AND ALL PERFORMED UNDER THE REQUIREMENTS OF BOEING SHEA, OSHA, EPA AND ANY EXTERIOR EQUIPMENT AND DEVICES, INSTALLED OR REVISED UNDER THIS CONTRACT. OTHER AUTHORITY HAVING JURISDICTION IN APPLICABLE STATE, CITY AND LOCAL THIS INCLUDES THOSE NOT PHYSICALLY RELOCATED BUT RECIRCUITED. SECURE CODES. NAMEPLATES TO EQUIPMENT USING SCREWS OR WIRE LOOP. ADHESIVES ARE NOT ACCEPTABLE. USE ENGRAVED NAMEPLATES, METAL OR PHENOLIC WITH 1 /4 INCH 6. CONTRACTOR TO FIELD VERIFY ALL EXISTING ELECTRICAL FEEDS. DISCONNECT AND WHITE LETTERS ON BLACK BACKGROUND ABANDON BELOW GRADE CONDUITS NOT IN USE. 3. PROVIDE WIRE AND CABLE MARKERS ON EACH CONDUCTOR IN PANEL BOARD r GUTTERS, PULL BOXES, OUTLET AND JUNCTION BOXES, AND AT ALL LOAD CY CONNECTIONS. IDENTIFY WITH BRANCH CIRCUIT OR FEEDER NUMBER AS INDICATED a C ON DRAWINGS. FOR CONTROL WIRING, IDENTIFY WITH WIRE NUMBER INDICATED ON C THE SCHEMATIC OR INTERCONNECTION DIAGRAMS. USE CLOTH MARKERS, SPLIT C SLEEVE OR TUBING TYPE I� 4. NAMEPLATES AND LABELS SHALL INDICATE PANEL AND CIRCUIT NUMBER EQUIPMENT T IS SERVED FROM. (E.G. - "1 G8/2abc" FOR CIRCUIT 2abc FROM PANEL 1 G8) d I. ALL SHUTDOWNS SHALL BE COORDINATED WITH BOEING AND APPROVED BY BOEING AT - LEAST 72 HOURS PRIOR TO DE-ENERGIZATION. J. CONTRACTOR TO COORDINATE THE APPROPRIATE AREA FOR STAGING AND EQUIPMENT STORAGE ON SITE WITH BOEING PRIOR TO MOBILIZATION. K. THERE SHALL BE NO EXPOSED GALVANIZED MATERIALS, COATINGS OR ZINC APPLIED SURFACE TREATMENTS ON ANY EXTERIOR OR UNDERGROUND MATERIALS OR SURFACES. ABBREVIATIONS ALL GALVANIZED OR ZINC APPLIED MATERIALS OR COATINGS SHALL BE PERMANENTLY PAINTED OR COATED TO PREVENT EXPOSURE OF THE GALVANIZED/ZINC MATERIALS PRIOR TO INSTALLATION OR COMPLETION OF CONSTRUCTION. AFF ABOVE FINISHED FLOOR AHC ABOVE HUNG CEILING AL ALUMINUM ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE CB CIRCUIT BREAKER C.O. CONDUIT ONLY CRU COMPUTER ROOM UNIT DED DEDICATED DP DISTRIBUTION PANEL BOARD EF EXHAUST FAN EMT ELECTRICAL METALLIC TUBING c EPO EMERGENCY POWER OFF T EWC ELECTRIC WATER COOLER li FACP FIRE ALARM CONTROL PANEL C FAR FIRE ALARM RELAY C FATU FAN TERMINAL UNIT r FVNR FULL VOLTAGE, NON -REVERSING T GFI GROUND FAULT INTERRUPTER a GND GROUND HP HORSEPOWER IMC INTERMEDIATE METAL CONDUIT LV LOW VOLTAGE M. BKR. MAIN BREAKER MCC MOTOR CONTROL CENTER MLO MAIN LUGS ONLY NACB NON -AUTOMATIC CIRCUIT BREAKER N.C. NORMALLY CLOSED N.O. NORMALLY OPEN PH PHASE PNL PANEL PVC POLY -VINYL CHLORIDE (CONDUIT) RF RETURN FAN RGS RIGID GALVANIZED STEEL (CONDUIT) RMC RIGID METALLIC CONDUIT RVNR REDUCED VOLTAGE, NON -REVERSING SRP SMOKE REMOVAL PANEL SRR SMOKE REMOVAL RELAY SWBD SWITCHBOARD SF SUPPLY FAN ST SHUNT TRIP CIRCUIT BREAKER THHN HEAT -RESISTANT THERMOPLASTIC (WIRE INSULATION TYPE) THWN MOISTURE- AND HEAT -RESISTANT THERMOPLASTIC (WIRE INSULATION CASNE ENGINEERING, INC. CE ELECTRICAL AND TECHNOLOGY CONSULTANTS TYPE) 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 U H UNIT HEATER (425) 522-1000 WWW. CASNE. COM JOB NO. 161-140 WP WEATHER PROTECTED XFMR TRANSFORMER [CIVIL PERMIT] BY I APPROVED I DATE Q� BOE/NG` C'- �4< G vo 35276 IST o�� `SI ONAL����� � 0 ACCEPTABILITY N. LAPRISE THIS DESIGN AND/OR CHECKED SPECIFICATION IS APPROVED S. SMITH N IN *SVED BY DEPT. I DATE P. JONES NIL SUBTITLE 11.04.16 SYMBOLS, ABBREVIATIONS & GENERAL NOTES 11.04.16 11.04.16 TITLE APRON R INFRASTRUCTURE ELECTRICAL MASTER CURRENT REVISION SYMBOL DATE W4700331 06.08.18 SHEET EO EO R E N TO N 01 T E JOB NO. COMP NO. W4700331 DWG N0. RENTON, WA 04-APRON-R-EO