R_4013170
LEGEND/SCHEDULE SYM REVISION APRON R INFRASTRUCTURE CONT. ON E4J—V50A BY W4700331 CASNE 13.8KV FROM TAP BOX AT COLUMN G6 2B12A 4"ALU 15KV, EPP, SHIELDED, 350 KCMIL F------- FF ----- V S IrJ IrJ TB 600A, 1 5KV,FUSED PT INTERRUPTER SW. (2) m IT CPT 14,937 APPROVED DATE SYM CEO 06.08.18 JLVV/1F 1500KVA 3000AT 13,800-480Y/277V 30,4W I 1 LKJ L REVISION 57,627/29,100 480V, 3000A BUS TU Tm D C CD CD C QQ D 0 CD CD 0cfl N CD CD 000 ocS ul 0:5 A 1200:5 800:5 SPARE �--� TIE TO SUB V50A '4J2 290' 42,000 PANEL G7-1 22,471 /16,326 800A 480/ 277 479 KVA 50' 1 1 /4"C, 3#4 � N Tm I C QQ 0 0 �o 0 o 800:5 '4J3 410' PANEL 17 800A 480/ 277 499 KVA 10' 1 1 /4"C, 3#4—\ 42,000 Tm I 0 0 CD CD 0--j- SRA 400:5 SPARE 17,890/13,782 20' 1 1 /4"C, 3#4 4J7 200' 18,000 CIRCUIT BREAKER TRIP SETTINGS CUTLER HAMMER DSII SOLID STATE BREAKER NO. SENSOR RATING PLUG RATING LONG TIME SHORT TIME INST. PICKUP GROUND FAULT PICKUP DELAY PICKUP DELAY PICKUP DELAY MAIN 3200A 3000A 1 12 4 0.1 0.4 0.1 1 C3 3200A 3000A 0.7 12 4 0.1 0.4 0.1 1C4 1200A 1200A 1 B 1 800A 800A 1 12 4 0.1 6 0.4 0.1 1 B2 800A 800A 1 12 4 0.1 6 0.4 0.1 1B3 400A 400A 1 B4 800A 800A 1 10 3 0.1 6 0.4 0.1 1A1 800A 800A 1 10 3 0.1 6 0.4 0.1 1A2 800A 1A3 800A 1A4 800A Tm I 0 �0 o 0 o0 800:5 25,000 VG6-6 800A 480/ 277 19,032/14,439 G8 400A 1 1,030/9,332 75' 25,000 L C oo \ o0 o o ��,(_0 c'� 4J8 150' 15' 14,000 50' 65,000 1 1 /4"C, 3#4 1 1 /4"C, 3#4 18,000 - 18,000 - 18,000 1 G63 ujii 200A 14,135/ 1 1, 440 15KVA ------ 15KVA ------ MPZ H7 MPZ 17 MPZ 17-1 om 10,000 - 10,000 P,-1�Z �� MPZ H5 1,460/1,448 1,450/1,438 1,450/1,438 1,442/1,429 1642/1517 BY I APPROVED I DATE C) 61"� 16P 3527IST 6 W� SIGNAL E�����gll 0 ACCEPTABILITY HGG THIS DESIGN AND/OR CITE( SPECIFICATION IS APPROVED DAT ENGI )Q—ROVED BY DEPT. DATE DAT aI CIE SUBTITLE 05.05.17 05.05.17 TITLE 05.05.17 ELECTRICAL MASTER XXX/XXX AVAILABLE FAULT CURRENT (CLOSED TRANSITION/NORMAL) XXX AIC RATING OF EQUIPMENT XXXX FEEDER LENGTH FEEDER SCHEDULE TYPE RATING CONDUIT CONDUCTORS PER CONDUIT QTY SIZE PHASE NEUTRAL GND 4F3 3000 A 7 4" 3-600 kcmil #2 4J 400 A 1 3" 3-600 kcmil 600 kcmil #2 4J2 800 A 2 4" 3-600 kcmil 600 kcmil #2 4J3 800 A 2 4" 3-600 kcmil 600 kcmil #2 4J4 800 A 2 4" 3600 kcmil 600 kcmil #2 5J 20A 1 1 " 8#14 AWG (SIS) (1)#14 #12 4J5 1200A 3 4" 3-600 kcmil 600 kcmil #3/0 4J7 400 A 1 3" 3600 kcmil #2 4J8 225 A 1 2 1 /2" 3—#410 #2 REFERENCE DRAIIII CS DWG 600SITEYDE1 BUILDING 04020 MEDIUM VOLTAGE FEEDER LOCATION DWG 600-SITE-YDE3 BUILDING 04-020 13.8KV SYSTEM PRIMARY SWITCHING DWG 04-020-E2 BUILDING 04-020 277/480V DISTRIBUTION 1ST FLOOR 04-020-HBL500 ELECTRICAL VAULT DETAILS DEVOLTOR MOTES DISCONNECT AND REMOVE CONDUCTORS FROM SOURCE BREAKER TO HARDSTAND TAP BOXES. REMOVE ABOVE GRADE CONDUIT AND ABANDON BELOW GRADE CONDUIT IN PLACE. 2� DISCONNECT AND REMOVE APRON R HARDSTAND AND ALL ASSOCIATED EQUIPMENT, DISCONNECTS, RECEPTACLES AND TAP BOXES. CECASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW. CASNE. COM JOB NO. 161-140 REMOVAL CIVIL PERMIT ONE LINE DIAGRAM APRON R INFRASTRUCTURE BUILDING 04-020 G/10 W47003311 06.08.18 SHEET E4J-V50BR E2 JOB NO. COMP N0. W4700331 RENTON, WA DWG N0. 04020E4JV50BR 0 c C' c C 0 T A L