Loading...
HomeMy WebLinkAboutR_4013185FROM PLATFORM "V9" PFD FDR 1A6B v/ ALT. FDR. i 2B12A EXIST. IN BEDG 4-20 2B12A PE „F„ „F„ 1A6B 12,387 I LJ � 600A,15KV,FUSED S1 MV SELECTOR SW. SYM REVISION A SUBSTATION V45A AND V45B INSTALLATION B ARC FLASH STUDY - RECORD DRAWING C APRON R INFRASTRUCTURE BY W1808396 CASNE CASNE CASNE W4700331 CASNE LOAD —--- --T :f14 PANEL "A9" MAXIMUM PEAK DEMAND METERED FOR 30 DAYS OF 2/25/13 76.7 AMPS PEAK DEMAND @ 125% PER NEC 220-87 95.9 AMPS PANEL "XA7-1 " MAXIMUM PEAK DEMAND METERED FOR 30 DAYS OF 2/25/13 21.1 AMPS PEAK DEMAND @ 125% PER NEC 220-87 26.4 AMPS 15KV CABLE 13,129 F----------------------� -I rl `1 1 I K PT/S2 CPT 1000/1333 kVA 125E 13,800-480Y/277V 30,4W .A. oa— _ TAP BOX LOADBANK 200A �200A 150KW@.8PF =_ 277/48OV, 30,4W CUMMINS MODEL 6CTA8.3-GSL S/N E890236048 SEE NOTE 1 (2) 1 A TB MAIN 2000:5(3) 2000AF1 N 2000AT 25T-1 52 86 25X-1 �o 0 25-1 11' � 2 SETS OF 800:5 4"C, 4#50OKCMIL, #1/0 GND 26,268/16,852 207 25,000 A9 2",4#4/0 800A DIST. + #2/0 GND LMAIN 85,000 72 NORMAL EMERGENCY 225A,3P AUTO TRANSFER SWITCH O 17,113/12,715 XA-7 14,000 225A LMLR & LTG DST NEW M LO 11 /2"C3#4 UNIT SUB V45A CIRCUIT BREAKER TRIP SETTINGS EATON MAGNUM DS WITH DIGITRIP 1150 BREAKER NO. SENSOR RATING PLUG RATING LONG TIME SHORT TIME INST. PICKUP GROUND FAULT MAINTENANCE MODE PICKUP DELAY PICKUP DELAY PICKUP DELAY MAIN 2000A 2000A 1 17.5 2.5 0.3 0.4 0.2 2.5 1 D 800A 800A 1 24 2.5 0.45 5 2.5 2A 2B 800A 800A 2C 800A 800A 2D 800A 800A 1 21 4 0.2 6 2.5 2B12A 65,000 48OV, 2000 BUS­7 , 5,752/22,89 Ln �� � � 00 00 �oo �oo 0000 S S A 800:5 A 800:5 PB 110 2 SETS OF (2)4"C PVC, 3#600kcmil 105 4"C, 3#50OKCM1 , 0,F #2/0 GND #1/0 GND MCC #1 1 800A (2)4"C PVC, 3#600kcmil 2 480V V45 #2/0 GND R14 35,000 34,886/20,362 -1 PULL BOX TAP BOX L 645 L 67 2 1-1 /2",3#2/0 „ O 2"RGS, 4#4/0 3#4/0 25 15,310/11,734 65,000 MCC #2 400A (225A) 480V 480V,30 1 /2" 3#8 EXIST. 11 /2"C3#6 65 �rr 30KVA XFMR, XA71 480 120/208V 2"C 4#4/0 30.44W O O �11/4",4#2 POWER XA7-1 TO MPZ (S. OF 100A E. BRIDGE APPROACH) EVER LTC M LO APPROVED DATE SYM CEC 07.16.14 RJJ 09.22.16 RJJ 12.20.17 DAL 06.08.18 REVISION XA7-2 225A 16,718/12,505 LMLR & LTG DIST MEO 14,000 —SEE NOTE 1 3"RGS, 4#4/0 112.5 KVA XFMR, A9- 2 C, 3#3/0, 48OV-120/208V 30,4W #1/0 GND � IY7 5 3"C-4# 500 MCM A9-2 500 400A PWR & LTG DST M EO 2",4#4/0 B8 l 225A PWR & LTG MAIN TO BLDG. 4-67 "BOATHOUSE" (CITY OF RENTON) _ - NOTE #1 D31 225A PWR & L_ MAIN VAULT V45A ORE E H E D AC RAM BY I APPROVED I DATE "T rrh A mzm 3 200A 12,214/9,737 MCB O 3/4"C, 2# 12, #12 GND KIRK KEY INTERLOCK TABLE SUBSTATION 45A S1 S2 MAIN OPEN EITHER SWITCH DOOR 0 0 0 CLOSE S1 0 0 CLOSE S2 0 0 OPEN S1 0 OPEN S2 0 "0" OPEN POSITION REQUIRED FOR OPERATION "S1" SWITCH 1 "S2" SWITCH 2 2000AF 135 (2)4"C PVC, 3#600kcmil #2/0 GND MPZ 365/364 R14-1 � R13 30A L TAP BOX MCB 0 2"C, 3#3/0, #1/0 GND 5 KVA 480V:120/240V R 13 10,804/8,825 3 200A MCB oy waste LUG ��� `6 35276 w� SIST I DNA� 0 0 3/4„C 2#12 #12 GND MPZ 364/363 R131 4 30A MCB 5 KVA 48OV:120/240V ACCEPTABILITY R. FARLEY THIS DESIGN AND/OR CHECKED SPECIFICATION IS APPROVED - ENGINEER 'ROVED BY DEPT. I DATE L.BOYER APPROVED 25X- EECOD/SCHCCE XXX/XXX AVAILABLE FAULT CURRENT SHOWN (CLOSED TRANSITION/NORMAL) XXX AIC RATING OF EQUIPMENT 0 XXX FEEDER LENGTH N FEET C 0 GENERAL MOTES c c 1. UNLESS OTHERWISE NOTED PROVIDE/INSTALL ALL p CONDUIT, WIRE, SUPPORTS, PANELS, TRANSFORMERS, T BREAKERS. C 2. ALL WORK SHOWN ON THE DRAWINGS AND INCLUDED IN THE SPECIFICATIONS SHALL BE INCLUDED IN THIS JOB, EXCEPT ASA SPECIFICALLY INDICATED OTHERWISE. 3. ELECTRICAL DEMOLITION: THIS ELECTRICAL SUBCONTRACTOR SHALL BE FULLY RESPONSIBLE FOR ALL ELECTRICAL DEMOLITION OF EXISTING ELECTRICAL SYSTEMS NOT BEING RE -USED. DELIVER ALL EXPLOSION PROOF ELECTRICAL EQUIPMENT TO THE OWNER FOR USE, DISPOSAL, OR INSTRUCTIONS. SEE DEMOLITION DRAWINGS OBSERVING AND EXECUTING THE GENERAL DEMOLITION NOTES AND THE NOTES ON EACH SHEET. ALSO INCLUDE THE SAME FOR THE DEMOLITION PHOTO BOOK. 4. THIS ELECTRICAL SUBCONTRACTOR SHALL ACQUAINT THEMSELVES WITH ALL THE DRAWINGS OF THE BID DOCUMENTS. THEY SHALL ESPECIALLY NOTE THE TYPE OF CONSTRUCTION N THE AIRCRAFT PAINT AREA AND T COORDINATE THE ELECTRICAL INSTALLATION WITH ALL a ASPECTS OF THIS CONSTRUCTION. C C 5. ALL CONTROL PANELS AND CONTROL STATIONS WHICH C ARE ELECTRICAL AND WHICH ARE FURNISHED WITH r EQUIPMENT PURCHASED BY OTHER TRADES SHALL BE T MOUNTED AND WIRED INTO THE SYSTEM. d 6. CLASSIFIED WIRING IN AND OUT OF CLASSIFIED AREAS: - THIS ELECTRICAL SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ALL CODE REQUIRED SEALS, DRAINS, ETC. FOR COMPLETION OF ALL WIRING IN CLASSIFIED AREAS SUCH AS CLASS 1, DIVISION 1, GROUP C & D AREA WHETHER SHOWN ON THE DRAWINGS OR NOT. 7. WIRING INSIDE AIRCRAFT PAINT HANGAR: ALL WIRING INSIDE THE AIRCRAFT PAINT HANGAR AREA SHALL BE CONCEALED OUTSIDE THE AREA IN SO FAR AS IS PHYSICALLY POSSIBLE. SEALS AND DRAINS FOR CLASSIFIED WIRING SHALL BE ACCESSIBLE. CONNECT PRIMARY SWITCH AUXILIARY CONTACTS TO POWER MONITOR FOR SWITCH POSITION STATUS REPORTING. TAP BOX REFERENCE DRAIIII NGS 0441E4 04-41-E8OX C CONSTRUCTOEI NOTSo PROVIDE PARALLEL SETS OF CONDUCTORS FROM SOURCE BREAKER TO HARDSTAND R13 TAP BOX. USE EXISTING CONDUIT RACEWAY TO PULL BOX ON 4-41 BUILDING. PROVIDE AND EXTEND RACEWAY FROM PULL BOX/PULE BOX TO HARDSTAND. PROVIDE NEMA 4X STAINLESS STEEL, OR APPROVED EQUAL, TAP BOX/PULE BOX. C PROVIDE 225A RATED, NEMA 4X SS, 48OV, 30, 3W PANELBOARD WITH 2O0A MAIN CIRCUIT BREAKER AND MOLDED CASE BRANCH BREAKERS. 4 PROVIDE 5KVA, 48OV:120/240V MINI POWER ZONE RATED FOR OUTDOOR INSTALLATIONS. PROVIDE BELOW GRADE CONDUIT AND CONDUCTORS. SEE PARTIAL PLAN VIEW DRAWINGS FOR ROUTING. SUBTITLE VAULT V45A - ONE LINE DIAGRAM TITLE APRON R INFRASTRUCTURE BUILDING 04-041 ELECTRICAL MASTER CECASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW. CASNE. COM JOB NO. 161-140 CIVIL PERMIT CURRENT REVISION SYMBOL DATE W4700331 C 06.08.18 SHEET E4 E17 JOB NO. COMP N0. W4700331 RENTON, WA DWG N0. 0441E4