HomeMy WebLinkAboutR_40131871000A BUS DUCT, 4-82 EAST 150A 3" C (4) #4/0 T 30KVA MP 100A MAIN 10,000 CURRENT LOAD - 330KVA NEW 480V LOAD - 266KVA NEW 208V LOAD - 240KVA 919KVA 1600A SWBD BUS - 480Y277V 30,000 20,355 PFD FEEDER ALT FEEDER 1 A7B (1 A6) 2B 14A (3C8) 13,972 13,398 CS-3 80E 1000KVA AA ONLY 13.8KV PRI - 480/277V SEC "Y7 Z=5.6% X/R=6.80 (3) 4"C, (4) 600 MCM, #4/0 GND - (3) 4"C, (4) 600 MCM, #4/0 GND 2 / 3� 4� 5� 6� 7 8� 9� 1600AF/AS /tl 600AF/AS �l 600AF/AS �l 600AF/AS � 600AF 600AF/AS 600AF/AS 600AF/AS > 1000AX / 400AX / 400AX / 400AX 400AT > 600AX > 600AX > 600AX 1000AT 4/ 380AT 4/ 380AT 4/ 240AT --- 600AT 600AT \t� 600AT 3-1 2 C, 3 C, (4) 500MCM (3) 500MCM 3 3 C, 0 (3) 500MCM EA. 80 200 20,355 15,619 > 18,940 UQ3.5 22,000 22,000 1MCC #13M 400A MLO 3" C 2-1/2" C, (3) #4/0 aR)l X (4) #4/0 1 (2) 2-1 /2"C 0 X 40' 1-1/2" C, (1) #3G0-- (4) #2 (3) #4 Q2.5 R5.5 225A 120A MLO M LO 14,000 14,000 12,318 9,992 1-1 /4" C, 50' (3) #4 80' SYM REVISION - RECORD DRAWING H APRON R INFRASTRUCTURE D CC123 POW CRIB - RECORD DRAWING 2R3 3Q4 225A 100A MLO M LO 14,000 14,000 13,583 11,955 1-1/4" C, 90' (3) #4 45 kVA _ _ _ = 45 kVA _ _ _ = 45 kVA 3" C, 3" C, 3" C, (4) #4/0 (4) #4/0 (4) #4/0 5' CD CD Q3.5 UR3.1 VR5 60A 225A 225A MAIN MLO MLO 10,000 10,000 10,000 3,137 3,048 3,005 10,000 3,914 3" C (4) #4/0 12,338 2Q4-1 400A MLO 25,000 19,085 1-1/4" C, (3) #4 BY APPROVED DATE SYM REVISION R-15137 CASNE RJJ 01.20.17 E RECONCILE W/MTTL W4700331 CASNE DAT 06.08.18 - AS BUILT - RECORD DRAWING 348738-002 HONARKHAH DH 9.26.00 F ARC FLASH STUDY SASCO KTL 2.11.04 G 04-81 SUB 1 CONDUIT/FEEDER 80' 2 3 C, (3) 500MCM EA. 17,697 CQ3 22,000 800A M LO 2-1/2" H=8O' (3) #4 0 UQ5-1 225A 175A CQ2 225A MLO 22,000 13,178 45 kVA (4) #2/0 5' Q4 225A CQ4 225A M LO 22,000 13,178 40' 1-1/4" C, (3) #4 45kVA 45 k,VA �/ » 4)1 1 /O , - (4) #4/0 5' Q5.5-1 225A BY APPROVED DATE 8813769 J.ANDRE D.BRANESKY 08.31.09 T DANG 6.12.14 16082502 CASNE DAT 11.19.15 CASNE RJJ 12.30.15 R-15137 CASNE RJJ 04.22.16 (2) 3-1/2" C, (4) 500MCM EA. 20' 19,624 22,000 U04 2" C, 800A (4) #2 MILO 3" C (3) 500MCM 80' 240' 22,000 15,130 Q4.5 R5.5 400A MLO MLO 22,000 4,776 1-1/4" C, (3) #4 110' 101 600AF 500AT CH UNIT SUBSTATION # V28A 600-000-V28A VAULT DATA SHEET 600-01A-007B FEEDER DATA SHEET 600-02B-014A FEEDER DATA SHEET 11� 800AF/AS > 800AX 800AT 12 \ 1600AF 13 SPACE 600AF --- SPACE SEE E4X-V28A 2) 3" C, (2) 4"C PVC, 3#600, #2/0 GND �4} 350MCM EA. � 350' BUILDING 04-083 SEE 04-81-82-E9 FOR 11,695 4-83 EM PANELS 15F0600A 14,000 2"C, 3 1 0 1 2"C, 3 1 0 2-1/2" C, (3) 350MCM 100' MAIN 5' 1-1/2" C, (4) #4 3/4" C, (3) # 10 MCC 11,258 MDPA UC4 D1-2 14,000 400A 100A 25,000 MLO MLO 10.998 14,000 9,331 3/4" C, (3) # 10 120' 5' 110 3/4" C, 3/4" C, (3) #8 100' (3) #8 u 15kVAf� i� i� M 15kVA 30kVA 75kVA rY N 10OA-NF 50' 25' 1-1/2" C, 1-1/ C, 1-1/4" C, 45 kVA (4) #8 (4) #8 (4) #2 45kVA rr, ? s } 150A (4) # 1 %0 (4) # 1 /0 D 1-1 D5 UC4-1 UC 100A 50A 100A 2,' --1 1/2 " /2" C, > (4) # 1 /0 0 O MAI N MAIN MAIN M 100' - 1-1/4" C, (3) #2 50' MCC MDP 25,000 9,562 45kVA ' ' 2-1/2" C, 1-1 /2" C (4) #4/0 (4) #8 5' 2-1/2" C, (4) #4/0 5' UC4-3 D5-1 225A ?? 10,000 MLO MAIN K4,768 HEAT TRACE 1�,090- 00 5 Q5 2R2 A 225A 150A 4,925 4,845 5,008 5,161 5,093 � 1600AF 1600AT 1600AF /1600ATT 20,555 TIE TO V2713/11 (2) 3-1/2" C, (4) 500MCM EA. 400' (2 2-1/2" C, (3 250kCMIL LEGEND FUSE CIRCUIT BREAKER, AIR, PULLOUT FRAME AND SENSOR RATING AS INDICATED 277/480V PANEL 120/208V PANEL U � TRANSFORMER, 480V/120/208V r7n UNLESS OTHERWISE NOTED CIRCUIT BREAKER, AIR �-° 0-- LIGHTNING ARRESTER XXX > AVAILABLE FAULT CURRENT (CLOSED TRANSITIONAL NORMAL) XXX EQUIPMENT AIC RATING XXX FEEDER LENGTH IN FEET REFERENCE DRAWINGS DRAWING # 04-81-82-E4 04-81-82-E4A 04-81-82-E4B 04-81-82-E4C 04-81-82-E4D 04-81-82-E4E 04-81-82-E4F 04-81-82-E4G 04-81-82-E4H 04-81-82-E5 SUBSTATION # V23A V23B V24A V24B V25A V25B V26A V27A (4-82) V28A (4-82) EMERGENCY SYSTEM 22,000 4,776 CONSTRUCTION NOTES PROVIDE CONDUIT AND CONDUCTORS FROM BREAKER TO APRON R HARDSTAND. SEE ONE -LINE CONTINUATION ON DRAWING E4X-V28A. J 300KVA (1) #2G ') 480V:208Y/120V L WITH HARMONIC FILTER 7.7% Z 1 (3) 4"C-(4) 400kCMIL, (1) #2/OG J 8,359 > 8,323 10,000 1 10,000 1 1 10,000 1 1 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 WAS L�T� BOEw W "dp 35276 0 1 STEg�' �SSIONAL� ACCEPTABILITY A.COWARD THIS DESIGN AND/OR CHECKED SPECIFICATION IS APPROVED A.WOOLF ENGINEER 'kROVED BY I DEPT. I DATE AL SUBTITLE 9.3.94 3.10.95 TITLE ELECTRICAL MASTER ONE -LINE DIAGRAM APRON R INFRASTRUCTURE BUILDING 04-81-82 VAULT V28A COL. Q4, LEVEL 2 2" C (4) # 1 (1) #6G TYPICAL CCASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW. CA SNE. COM JOB NO. 161-140 CIVIL PERMIT CURRENT REVISION SYMBOL DATE W4700331 H 06.08.18 SHEET E4H-V28A E19 JOB NO. COMP NO. W4700331 RENTON, WA DWG N0. 04-81-82-E4H-V28A 0 C 0 0 C C 0 T T li