Loading...
HomeMy WebLinkAboutT-388312SECTION 25, TOWNSHIP 23 NORTH, RANGE 4 E, W.M. T 0 z J z Q Ir Cn 0 I_LI n ILLUMINATION WIRING SCHEDULE RACEWAY CONDUIT SIZE ILLUM. #8 EQUIP. GRND. PULL WIRE N0. EX NEW I EX NEW EX NEW 1 2" SCH40 PVC 2 1 2" EXISTING** 2 1 2 2" EXISTING SPARE** 1 3 2" EXISTING** 2 1 * EQUIPMENT GROUND SIZE SHALL BE EQUAL TO OR LARGER THAN THE LARGEST WIRE SIZE IN THE CONDUIT. ** OTHER CONDUIT AND CONDUCTORS MAYBE PRESENT. ILLUMINATION POLE SCHEDULE LUM. POLE ID STREET STATION *OFFSET *LATITUDE ** LONGITUDE ** MOUNT. ARM VOLTAGE SERVICE/ WATTAGE LUMINAIRE TYPE - BASE COMMENT POLE NO. NUMBER*** HEIGHT LENGTH CIRCUIT TYPE DISTRIBUTION AO SW 27TH ST 98+40.5 1.5' RT 14.0' 4. 0' 240 ILLUM A 35 LED CYCLONE DOMIA LIGHTING FIXED NEW FOUNDATION AND POLE PER RENTON SY21 P 1-GAL-3-35W-4K-240-CP3924-RAL9005TX STANDARD PLAN 117.1. ®BSW 27TH ST 96+90.5 1.0' RT 14.0' 4.0' 240 ILLUM A 35 LED CYCLONE DOMIA LIGHTING FIXED NEW FOUNDATION AND POLE PER RENTON SY21 P 1-GAL-3-35W-4K-240-CP3924-RAL9005TX STANDARD PLAN 117.1. 0SW 27TH ST 95+50.0 1.5' RT 14.0' 4.0' 240 ILLUM A 35 LED CYCLONE DOMIA LIGHTING FIXED NEW FOUNDATION AND POLE PER RENTON SY21 P 1-GAL-3-35W-4K-240-CP3924-RAL9005TX STANDARD PLAN 117.1. 0SW 27TH ST 94+22.5 13.0' LT 14.0' 4. 0' 240 ILLUM A 35 LED CYCLONE DOMIA LIGHTING FIXED NEW FOUNDATION AND POLE PER RENTON SY21 P 1-GAL-3-35W-4K-240-CP3924-RAL9005TX STANDARD PLAN 117.1. 0SW 27TH ST 93+45.0 29.5' LT 14.0' 4.0' 240 ILLUM A 35 LED CYCLONE DOMIA LIGHTING FIXED NEW FOUNDATION AND POLE PER RENTON SY21 P 1-GAL-3-35W-4K-240-CP3924-RAL9005TX STANDARD PLAN 117.1. * STATIONS/OFFSETS ARE APPROXIMATE. CONTRACTOR SHALL CONFIRM ADJUSTMENTS WITH CITY INSPECTOR PRIOR TO IMPLEMENTING. ** POLE LATITUDE AND LONGITUDE NUMBERS SHALL BE PROVIDED BY CONTRACTOR FOR INCORPORATION INTO AS -BUILT PLANS. *** POLE ID NUMBERS SHALL BE PROVIDE BY ERIC CUTSHALL (CITY OF RENTON) FOR CONTRACTOR TO INSTALL AND INCORPORATE INTO AS -BUILT PLANS. R/W W w FBR R/W FBR FBR - FBR FBR 1 1 B 1 1 97+00 - - 97+50 Q SW 27TH ST FBR F R FBR - = FBR - - - ILLUMINATION GENERAL NOTES 1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON UTILITY DEPARTMENT, CURRENT EDITION AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON -SITE AT ALL TIMES DURING CONSTRUCTION. 2. THE HOURS OF WORK IN THE STREET RIGHT-OF-WAY SHALL BE LIMITED TO 8:30 AM TO 3:30 P.M. ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE DEPARTMENT OF PUBLIC WORKS. ALL STREET CLOSURES, PARTIAL OR FULL, SHALL BE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS 72 HOURS IN ADVANCE. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE. 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. FOR UTILITY LOCATE CALL 48-HOUR LOCATORS, 1-800-424-5555. 4. A PRECONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON). IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE UTILITY DEPARTMENT 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. 5. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION. 7. PLANS APPROVED BY THE CITY OF RENTON PUBLIC WORKS ADMINISTRATOR SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS. 8. ALL UTILITY TRENCHES SHALL BE BACKFILLED AND COMPACTED TO 95% MAXIMUM DRY DENSITY MODIFIED PROCTOR. 9. THE CONTRACTOR SHALL PROVIDE MATERIALS SUBMITTALS AND POLE SHOP DRAWINGS TO THE CITY OF RENTON FOR APPROVAL MINIMUM 3 WEEKS PRIOR TO THE DESIRED APPROVAL DATE. 10. AS PART OF THE DESIGN PROCESS, THE ENGINEER HAS ATTEMPTED TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH OVERHEAD POWER LINES OR SUBSURFACE UTILITIES. HOWEVER, IT IS POSSIBLE FOR THE EXISTING OR PROPOSED CONDITIONS TO CHANGE PRIOR TO IMPLEMENTATION OF THE SCOPE OF WORK IDENTIFIED ON THESE DOCUMENTS. AS THE FIRST ORDER OF BUSINESS, THE CONTRACTOR SHALL POTHOLE EACH POLE LOCATION TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH SUBSURFACE UTILITIES. ADDITIONALLY, THE CONTRACTOR SHALL CONFIRM THAT THERE IS A MINIMUM 10-FT CLEARANCE PROVIDED BETWEEN OVERHEAD POWER LINES AND THE PROPOSED LUMINAIRE POLES PRIOR TO POLE PLACEMENT. ADDITIONAL CLEARANCE MAY BE REQUIRED AS DIRECTED BY THE UTILITY. THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY IF A CONFLICT IS DISCOVERED. 11. CONTRACTOR SHALL RESTORE ALL GROUNDS DISTURBED BY CONDUIT AND ILLUMINATION SYSTEM INSTALLATION, INCLUDING BUT NOT LIMITED TO: LANDSCAPING, IRRIGATION, CONCRETE SIDEWALKS, ETC. 12. THE LOCATION OF FEATURES SHOWN SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR WITH THE CITY OF RENTON TRANSPORTATION MAINTENANCE ASSISTANT MANAGER, ERIC CUTSHALL, AT (425) 430-7423. KIR %9TENW ��; OF WAsy • ;��' Transportation Engineering NorthWest - 0 1 ASBUILT DRAWINGS Transportation Planning I Design I Traffic Impact & Operations .e� •°'p 356 O ° _ 1 1400 SE 8th Street, Suite 200, Bellevue, WA 98004 Office (425) 889-6747 S°•°•°, S7 G Project Contact: Jaedi Stevens AL 3.1% Phone: 425-250-0868 06 NO. REVISION 1 - - - - - - 1 a m� -w w w- 1 12" 11FUEL FUEL LV1___0 r 3 3 3 R/W / - - • ® I NA • 2" WrR 12" W)rR- M �i • I M I w / o ®® I ® 100+00 (2 7 -LINE) �J9+00 +50 10 ---------------- - FBR F FBR - �y-� FBIR FBR R - - FBR FBR FBR R% " FBR ILLUMINATION CONSTRUCTION NOTES DINSTALL FOUNDATION, POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE, SHEET IL-02, AND PER CITY OF RENTON STANDARD PLANS 117.2, 117.3, 119, 120, 121, 123, 125 & J013 ON SHEET IL-03. (DEXISTING LUMINAIRE TO REMAIN. (DINTERCEPT AND EXTEND EXISTING CONDUIT AND EXTEND TO THE EXISTING JUNCTION BOX. SPLICE NEW ILLUMINATION CONDUCTORS WITH EXISTING CONDUCTORS IN EXISTING JUNCTION BOX PER CITY OF RENTON STANDARD PLAN J013 ON SHEET IL-03. SIGNAL AND ILLUMINATION LEGEND EX NEW/RELOCATE DESCRIPTION ®� m m JUNCTION BOX TYPE 1,2,8 (SKID -RESISTANT) H MAST ARM MOUNTED SIGN VEHICLE SIGNAL HEAD PEDESTRIAN SIGNAL HEAD -� VIDEO DETECTION CAMERA LUMINAIRE POLE SIGNAL POLE TYPE III AIRE PEDSTRIAN POMIN 0 TYPE PPB OR PS POLE F PPB -A TENON - - - - - - CONDUIT/CONDUCTOR ® ELECTRICAL SERVICE CABINET W/BPS ® CONTROLLER CABINET OCONSTRUCTION NOTE SIGNAL POLE NUMBER/ CONSTRUCTION NOTE AWIRE NOTE EX BREAKER SCHEDULE CIRCUIT BREAKER CONTACTOR VOLTS MAIN 2P-200 AMP --- 1201240 SIGNAL 1 P-50 AMP --- 120 ILLUM A SIGNAL ILLUM 2P-20 AMP 30 AMP 240 ILLUM B SPARE 2P-20 AMP r3O AMP 240 .I, �I 10 40 0 20 60 SCALE IN FEET A-NNNNNNN IN COMPLIANCE WITH CITY OF RENTON STANDARDS 11 30 18 SURVEYED: SCALE: HORIZONTAL: NAD D1983/1991 DATU M •ONTAL: *- C T Y O E RENTON Planning/Building/Public Works Dept. GHC LONGACRES - PEDSTRIAN LIGHTING RENTON WASHINGTON ILLUMINATION PLAN DATE: 06/23/ 17 DESIGNED: JLs FIELDBOOK: PAGE: DRAWN: JLS ONE INCH DRAWING NO: I L-01 CHECKED:GIVID AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY BY DATE APPR APPROVED: SHEET: 1 OF:CTB 3 T-388312 U a J G z 0 J z IO LU 0- W IIr CU Q 0 z O J CU 0