HomeMy WebLinkAboutT-388312SECTION 25, TOWNSHIP 23 NORTH, RANGE 4 E, W.M.
T
0
z
J
z
Q
Ir
Cn
0
I_LI
n
ILLUMINATION WIRING SCHEDULE
RACEWAY
CONDUIT
SIZE
ILLUM.
#8
EQUIP.
GRND.
PULL
WIRE
N0.
EX
NEW
I EX
NEW
EX
NEW
1
2" SCH40 PVC
2
1
2" EXISTING**
2
1
2
2" EXISTING SPARE**
1
3
2" EXISTING**
2
1
* EQUIPMENT GROUND SIZE SHALL BE EQUAL TO OR LARGER THAN
THE LARGEST WIRE SIZE IN THE CONDUIT.
** OTHER CONDUIT AND CONDUCTORS MAYBE PRESENT.
ILLUMINATION POLE SCHEDULE
LUM.
POLE ID
STREET
STATION *OFFSET
*LATITUDE
**
LONGITUDE **
MOUNT.
ARM
VOLTAGE
SERVICE/
WATTAGE
LUMINAIRE TYPE -
BASE
COMMENT
POLE NO.
NUMBER***
HEIGHT
LENGTH
CIRCUIT
TYPE
DISTRIBUTION
AO
SW 27TH ST
98+40.5
1.5' RT
14.0'
4. 0'
240
ILLUM A
35 LED
CYCLONE DOMIA LIGHTING
FIXED
NEW FOUNDATION AND POLE PER RENTON
SY21 P 1-GAL-3-35W-4K-240-CP3924-RAL9005TX
STANDARD PLAN 117.1.
®BSW
27TH ST
96+90.5
1.0' RT
14.0'
4.0'
240
ILLUM A
35 LED
CYCLONE DOMIA LIGHTING
FIXED
NEW FOUNDATION AND POLE PER RENTON
SY21 P 1-GAL-3-35W-4K-240-CP3924-RAL9005TX
STANDARD PLAN 117.1.
0SW
27TH ST
95+50.0
1.5' RT
14.0'
4.0'
240
ILLUM A
35 LED
CYCLONE DOMIA LIGHTING
FIXED
NEW FOUNDATION AND POLE PER RENTON
SY21 P 1-GAL-3-35W-4K-240-CP3924-RAL9005TX
STANDARD PLAN 117.1.
0SW
27TH ST
94+22.5
13.0' LT
14.0'
4. 0'
240
ILLUM A
35 LED
CYCLONE DOMIA LIGHTING
FIXED
NEW FOUNDATION AND POLE PER RENTON
SY21 P 1-GAL-3-35W-4K-240-CP3924-RAL9005TX
STANDARD PLAN 117.1.
0SW
27TH ST
93+45.0
29.5' LT
14.0'
4.0'
240
ILLUM A
35 LED
CYCLONE DOMIA LIGHTING
FIXED
NEW FOUNDATION AND POLE PER RENTON
SY21 P 1-GAL-3-35W-4K-240-CP3924-RAL9005TX
STANDARD PLAN 117.1.
* STATIONS/OFFSETS ARE APPROXIMATE. CONTRACTOR SHALL CONFIRM ADJUSTMENTS WITH CITY INSPECTOR PRIOR TO IMPLEMENTING.
** POLE LATITUDE AND LONGITUDE NUMBERS SHALL BE PROVIDED BY CONTRACTOR FOR INCORPORATION INTO AS -BUILT PLANS.
*** POLE ID NUMBERS SHALL BE PROVIDE BY ERIC CUTSHALL (CITY OF RENTON) FOR CONTRACTOR TO INSTALL AND INCORPORATE INTO AS -BUILT PLANS.
R/W
W w
FBR
R/W
FBR
FBR
- FBR
FBR
1
1
B
1 1
97+00 - - 97+50
Q
SW 27TH ST
FBR F R
FBR - = FBR - -
-
ILLUMINATION GENERAL NOTES
1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON UTILITY
DEPARTMENT, CURRENT EDITION AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS. A SET OF
APPROVED PLANS SHALL BE KEPT ON -SITE AT ALL TIMES DURING CONSTRUCTION.
2. THE HOURS OF WORK IN THE STREET RIGHT-OF-WAY SHALL BE LIMITED TO 8:30 AM TO 3:30 P.M. ON WEEKDAYS UNLESS
OTHERWISE APPROVED IN WRITING BY THE DEPARTMENT OF PUBLIC WORKS. ALL STREET CLOSURES, PARTIAL OR FULL, SHALL BE
APPROVED BY THE DEPARTMENT OF PUBLIC WORKS 72 HOURS IN ADVANCE. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911
SHALL BE NOTIFIED 24 HOURS IN ADVANCE.
3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO
VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. FOR UTILITY LOCATE CALL 48-HOUR
LOCATORS, 1-800-424-5555.
4. A PRECONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT
SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION.
(INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON). IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO NOTIFY THE UTILITY DEPARTMENT 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION.
5. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF
WORKERS AND OTHERS ON THE CONSTRUCTION SITE.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY
CONSTRUCTION.
7. PLANS APPROVED BY THE CITY OF RENTON PUBLIC WORKS ADMINISTRATOR SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS.
8. ALL UTILITY TRENCHES SHALL BE BACKFILLED AND COMPACTED TO 95% MAXIMUM DRY DENSITY MODIFIED PROCTOR.
9. THE CONTRACTOR SHALL PROVIDE MATERIALS SUBMITTALS AND POLE SHOP DRAWINGS TO THE CITY OF RENTON FOR APPROVAL
MINIMUM 3 WEEKS PRIOR TO THE DESIRED APPROVAL DATE.
10. AS PART OF THE DESIGN PROCESS, THE ENGINEER HAS ATTEMPTED TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH OVERHEAD
POWER LINES OR SUBSURFACE UTILITIES. HOWEVER, IT IS POSSIBLE FOR THE EXISTING OR PROPOSED CONDITIONS TO CHANGE
PRIOR TO IMPLEMENTATION OF THE SCOPE OF WORK IDENTIFIED ON THESE DOCUMENTS. AS THE FIRST ORDER OF BUSINESS, THE
CONTRACTOR SHALL POTHOLE EACH POLE LOCATION TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH SUBSURFACE UTILITIES.
ADDITIONALLY, THE CONTRACTOR SHALL CONFIRM THAT THERE IS A MINIMUM 10-FT CLEARANCE PROVIDED BETWEEN OVERHEAD
POWER LINES AND THE PROPOSED LUMINAIRE POLES PRIOR TO POLE PLACEMENT. ADDITIONAL CLEARANCE MAY BE REQUIRED AS
DIRECTED BY THE UTILITY. THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY IF A CONFLICT IS DISCOVERED.
11. CONTRACTOR SHALL RESTORE ALL GROUNDS DISTURBED BY CONDUIT AND ILLUMINATION SYSTEM INSTALLATION, INCLUDING BUT NOT
LIMITED TO: LANDSCAPING, IRRIGATION, CONCRETE SIDEWALKS, ETC.
12. THE LOCATION OF FEATURES SHOWN SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR WITH THE CITY OF RENTON
TRANSPORTATION MAINTENANCE ASSISTANT MANAGER, ERIC CUTSHALL, AT (425) 430-7423.
KIR
%9TENW
��; OF WAsy • ;��'
Transportation Engineering NorthWest - 0 1 ASBUILT DRAWINGS
Transportation Planning I Design I Traffic Impact & Operations
.e� •°'p 356 O ° _ 1 1400 SE 8th Street, Suite 200, Bellevue, WA 98004
Office (425) 889-6747 S°•°•°, S7 G
Project Contact: Jaedi Stevens AL 3.1%
Phone: 425-250-0868
06 NO. REVISION
1
- - - - - -
1
a m�
-w w w-
1
12" 11FUEL
FUEL
LV1___0 r
3 3
3
R/W / - - •
® I
NA
•
2" WrR 12" W)rR- M
�i • I M
I
w / o ®® I
® 100+00 (2 7 -LINE)
�J9+00 +50 10
----------------
- FBR F FBR - �y-�
FBIR
FBR R - - FBR FBR FBR R% "
FBR
ILLUMINATION CONSTRUCTION NOTES
DINSTALL FOUNDATION, POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION POLE
SCHEDULE, SHEET IL-02, AND PER CITY OF RENTON STANDARD PLANS 117.2, 117.3,
119, 120, 121, 123, 125 & J013 ON SHEET IL-03.
(DEXISTING LUMINAIRE TO REMAIN.
(DINTERCEPT AND EXTEND EXISTING CONDUIT AND EXTEND TO THE EXISTING JUNCTION
BOX. SPLICE NEW ILLUMINATION CONDUCTORS WITH EXISTING CONDUCTORS IN EXISTING
JUNCTION BOX PER CITY OF RENTON STANDARD PLAN J013 ON SHEET IL-03.
SIGNAL AND ILLUMINATION LEGEND
EX
NEW/RELOCATE
DESCRIPTION
®� m
m
JUNCTION BOX TYPE 1,2,8
(SKID -RESISTANT)
H
MAST ARM MOUNTED SIGN
VEHICLE SIGNAL HEAD
PEDESTRIAN SIGNAL HEAD
-�
VIDEO DETECTION CAMERA
LUMINAIRE POLE
SIGNAL POLE TYPE III
AIRE PEDSTRIAN
POMIN
0
TYPE PPB OR PS POLE
F
PPB
-A
TENON
- - -
- - -
CONDUIT/CONDUCTOR
®
ELECTRICAL SERVICE
CABINET W/BPS
®
CONTROLLER CABINET
OCONSTRUCTION
NOTE
SIGNAL POLE NUMBER/
CONSTRUCTION NOTE
AWIRE
NOTE
EX BREAKER SCHEDULE
CIRCUIT
BREAKER
CONTACTOR
VOLTS
MAIN
2P-200 AMP
---
1201240
SIGNAL
1 P-50 AMP
---
120
ILLUM A
SIGNAL ILLUM
2P-20 AMP
30 AMP
240
ILLUM B SPARE
2P-20 AMP
r3O AMP
240
.I,
�I
10 40
0 20 60
SCALE IN FEET
A-NNNNNNN
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
11 30 18
SURVEYED:
SCALE:
HORIZONTAL: NAD D1983/1991
DATU M
•ONTAL:
*- C T Y O E
RENTON
Planning/Building/Public Works Dept.
GHC LONGACRES - PEDSTRIAN LIGHTING
RENTON WASHINGTON
ILLUMINATION PLAN
DATE:
06/23/ 17
DESIGNED:
JLs
FIELDBOOK:
PAGE:
DRAWN: JLS
ONE INCH
DRAWING NO:
I L-01
CHECKED:GIVID
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
BY
DATE
APPR
APPROVED:
SHEET: 1 OF:CTB 3
T-388312
U
a
J
G
z
0
J
z
IO
LU
0-
W
IIr
CU
Q
0
z
O
J
CU
0