Loading...
HomeMy WebLinkAboutR-404909DRAINAGE EASEMENT - PLAN & PROFILE m W z Li L� �- �,- oo � 00000000�o�o... VERTICAL: 1" =5 Know what's below. Call before you dig. Dial 811 EX. TOPOGRAPHY/SURVEY INFORMATION NOTE: PROJECT ENGINEER DOES NOT WARRANT THAT THE TOPOGRAPHY SHOWN ON THESE DRAWINGS IS REPRESENTATIVE OF WHAT IS EXISTING AND/OR CONSTRUCTED. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE OWNER TO HAVE ALL IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT ENGINEER PRIOR TO WORK. UTILITIES AND UTILITY EASEMENTS FOR THIS SITE HAVE NOT BEEN RESEARCHED OR CONFIRMED. UTILITY CONFLICT NOTE - THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE @ 1-800-424-555 AND THEN POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT PROJECT ENGINEER TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. rt •I II ► • I,INNES�.� STRUCTURE TABLE CB#2, TYPE 2-48" W/ STANDARD GRATE RIM = 168.44 IE=162.51 (12" E) IE=162.51 (12" S) IE=163.89 (6" S) IE=162.51 (12" W) CB#4, TYPE 2-48" W/ STANDARD GRATE RIM = 169,88 IE=163.1 1 (12" W) IE=163.11 (12" N) 175 155 I / / I / II - I 00 1�2 cg N N ur -r- - It DRAINAGE EASEMENT PLAN VIEW SCALE: 1 "=10' I ME I LF6"P' �0' 171.29 '' '171- b\ I 7 M N L N (n re z r w cTI IX N o o N o w cn U a / T N Ln lJ r (N L/ F Cn ry W (n 1► (n ICn 168.41 / 35 d O.50% I � r r N STUB I (n L I M Ln / o -_III■ • t���=•1•ll=•L���=�•R•1�![•�IIIIIIIIIIII■-_III■ -1111111 �-1111111 - IIIII, - IIIII, - IIIII, YY L - IIIII, - IIIII, - IIIII, IIIII, - IIIII, _- �I �MEL�;:� - _ ° OF . :: ���.17��4.11•IC�U : ii- � �a•r�risv� • L81 15 J3NP EN GI N EERI N G 1735 POINTE WOODWORTH DR NE TACOMA, WA 98422 (206) 730-3348 NO. \/ \/ \/ \/ \/ \/ \/ \/ \/ 1DRAINGE EASEMENT PROFILE VIEW HORIZONTAL: 1 "=10' VERTICAL: 1 "=5' REVISION SURVEYED: DESIGNED: J3NP DRAWN, J3NP CHECKED: J3NP BY DATE APPR A'ROVEJ3NP SCALE: 1 "=10, ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM 1+40 A • T4 41 of w A s,y/ f j, �0 9 37819 p �� F��STER�` ��� S��NA L �-NG 04117/2019 - N CITY OF RENTON Plonning/Building/Public Works Dept. R-404909 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING SURFACE WATER UTILITY , jchavez 04/23/2019 jfarah 04/26/2019 SINGH & SAHOTA RESIDENCES 1129 & 1133 N. 33R D PLACE CIVIL PERMIT N 33RD PLACE STREET IMPROVEMENTS DRAINAGE EASEMENT - PLAN & PROFILE DATE: 2/11/19 PAGE: R3 SHEET: Z OFc c ME