HomeMy WebLinkAboutPlan Review Comments - PRE App 16-000053
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE: February 9, 2016
TO: Rocale Timmons, Planner
FROM: Vicki Grover, Plan Review
SUBJECT: Kennydale Apartments
1901 NE 48th Street
Pre- App 16-000053
NOTE: The applicant is cautioned that information contained in this summary is preliminary and non-
binding and may be subject to modification and/or concurrence by official City decision-makers. Review
comments may also need to be revised based on site planning and other design changes required by
City staff or made by the applicant.
I have completed a preliminary review for the above-referenced proposal. The following comments are
based on the pre-application submittal made to the City of Renton by the applicant for tax parcel
number 3343300820.
Water
1. There is an existing 12-inch water main in NE 48th Street. This development is in the 320-water
pressure zone. Static water pressure is 100 psi at street level. A pressure reducing valve will be required
to be installed at each domestic meter.
2. The Applicant will be required to extend the 12-inch water main in NE 48th Street to the easterly
property line and provide a 12-inch looped water main on site. A connection to an existing 12-inch main
near the southwest property line will also be required. See City water drawing W-104404.
3. Water system development fees will be based on the size of the domestic water meter(s), fire
service line and irrigation meter(s). This is payable prior to issuance of the construction permit.
4. Buildings exceeding 30 feet in height require installation of a reduced pressure backflow assembly
inline of all domestic water meter(s).
5. Landscape irrigation systems will require a separate permit for the irrigation meter and approved
backflow device is required to be installed. A plumbing permit will be required.
Sanitary Sewer
1. Sewer service is provided by Coal Creek Water and Sewer District.
2. Applicant shall provide a Sewer Availability Certificate from Coal Creek at site plan application.
Kennydale Apartments Pre - App 16-000053
Page 2 of 3
February 9, 2016
3. Applicant proposes underground parking garages. The building department will require floor drains,
which will need to be connected to the sanitary sewer through an approved oil/water separator located
outside the building, if feasible.
4. Applicant shall provide the City of Renton with approved sewer plans from Coal Creek Utility District
at application for utility construction permit submittal.
Storm Drainage
1. There is an existing drainage conveyance system in NE 48th Street.
2. A drainage plan and drainage report will be required with the site plan application. The report shall
comply with the 2009 King County Surface Water Manual and the 2009 City of Renton Amendments to
the KCSWM. All core and any special requirements shall be contained in the report. Based on the City’s
flow control map, this site falls within the Flow Control Duration Standard, Forested Conditions. The site
is within the East Lake Washington – Bellevue South Drainage Basin. This is a commercial site which
requires enhanced water quality.
3. A geotechnical report for the site is required. Information on the water table and soil permeability for
infiltration, with recommendations from the geotechnical engineer for appropriate flow control BMP
options with typical designs for the site, shall be submitted with the site plan application.
4. Surface Water System Development fees of $0.594 per square foot of new impervious surface and
not less than $1,485.00 will apply. This is payable prior to issuance of the construction utility permit.
5. Applicant will be required to submit separate structural plans for review and approval under a building
permit for the proposed underground storm water vault. Special inspection from the building
department is required.
6. The location of the proposed vaults and rain garden are not able to gravity flow to the existing system
within NE 48th Street; the location of these facilities above proposed walls will add additional loading
that will need to be designed for by the structural engineer for the walls.
Transportation/Street
1. A new traffic analysis (TIA) will be required to be submitted with the site plan application. The
analysis will need to identify potential traffic issues and provide recommendations of necessary
improvements to insure safe and efficient traffic circulation to and from the site. The traffic analysis
shall include addressing the traffic operations at the proposed driveway and identify any site distance
problems. The center turn lane in NE 48th will be required to be extended to the east. Coordination with
the City of Newcastle will be required for the extension to the east of the center turn lane. The study
should also include potential traffic impacts at the intersections of Lake Wash. Blvd. and NE 48th Street
and Lake Wash. Blvd. and NE 44th. In addition, the signalization requirements for the intersections at the
off ramps at exit 7 and I-405 is required to be considered in the TIA.
2. Traffic mitigation fees shall be assessed based on use as determined from the ITE trip generation
manual and the City of Renton’s Ordinance number 5670 at building permit submittal.
3. Frontage improvements are to be as approved on the Site Plan Application in 2012.
General Comments
1. A construction utility permit submittal for site utilities and street improvements will require separate
plan submittals from the building permits. All utility plans shall conform to the Renton Drafting
Kennydale Apartments Pre - App 16-000053
Page 3 of 3
February 9, 2016
Standards. Plans shall be prepared by a licensed Civil Engineer. Please submit 4 set of civil plans and 2
copies of the Drainage and Geotech reports.