HomeMy WebLinkAboutMFP19005588.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Minor Franchise Permit: MFP19005588
IVR Number: 19005588
Permit Informaon
Permit Name:Seattle City Light
Address/Locaon :10/17/2019Application Date:8898700600Parcel Number:901 S 23RD ST
Permit Type:11/04/2019Issue Date:Franchise
Permit Work Class:11/03/2020Expiration Date:Minor Utility
Job Number:WO#1812641Franchise Type:Electric
Description:Replace 1 failing pole adjacent to old pole at 901 S 123rd St. Restoration per City of Renton standards.
APPROVED WITH COMMENTS OR REDLINES
Contacts
Name Address PhoneTypeBilling
Senait Telahun
SEATTLE CITY LIGHT
700 5th Ave, Suite 3200, PO 34023
SEATTLE, WA 98124
B: (206) 615-0629ApplicantX
Mark Nagasawa
SEATTLE CITY LIGHT
700 5th Ave, Suite 3200 Po Box
34023 (ms-S/7)
Seattle, WA 98124
B: (206) 615-0667Contact
Fernando Estadillo
Seattle City Light
PO Box 34023
Seattle, WA 98124-4023
B: (206) 625-3000
C: (206) 684-3832
Contact
CARMEN RODRIGUEZ-ORTON
SEATTLE CITY LIGHT
700 5th Ave, Suite 3200, PO 34023
Seattle, WA 98124
Contact
MAI JOANNE 2011 DAVIS AVE S
RENTON , WA 98055
Owner
General Condions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
This permit and plans must be posted at the job site at all times.
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Call 425.430.7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
-07RESTORATION PER CITY OF RENTON STANDARDSScott Warlick10/30/2019MFP19005588901 S 23rd STHolly Powers11/4/2019
Monday - Friday8:00AM - 3:00PMScott Warlick10/30/2019MFP19005588
S 23RD ST
P445BENSON DR SBrief Job Description:
TWR-CF23/378, P445, CEDAR FALLS 23/378 -
SS SEATTLE PIPE LINE R/W 5W SSH 5C
~REPLACE POLE
~TRANSFER EQUIPMENT
UTILITY
WORK
AHEAD
A
B
C
RIGHT
LANE
ENDS
L
50’11’ MINR
9
-
9R9-9PED ACCESSS.C.L TRAFFIC CONTROL
WO # 1812641-07 Date: 5/10/19
Location: 901 S 23RD ST
Project Engineer: M. KELLEY
TCP: njmr
RENTON-A
START DATE: PENDING
SPEED
LIMIT
40
N
NTS
152NE
FLAGGER (IF APPLICABLE)
LEGEND
CHANNELIZING DEVICES
WORK VEHICLE
F
SIGN LOCATION
WORK AREA
OR
SEQUENTIAL ARROW PANEL
HIGH LEVEL WARNING DEVICE
Arterial streets, travel lanes and
sidewalks shall remain open during
peak traffic hours:
6am to 9am
3pm to 7pm
MONDAY-FRIDAY
PERMIT#________S.C.L. TRAFFIC CONTROL PLAN
4 LANE 2 WAY ARTERIAL - RIGHT LANE CLOSURE
SCL WILL CLOSE THE NORTHBOUND TRAVEL LANE ON BENSON DR S AT S 23RD ST TO REPLACE A BAD POLE.
NOTE: REFER TO TABLE X- 1FOR TYPICAL DIMENSIONS OF A, B, C & L., NOTE: NOTIFY SCHOOLS & METRO 10
DAYS IN ADVANCE (IF APPLICABLE) MAY NEED SPOTTER TO ASSIST WITH LOCAL TRAFFIC.
NOTE: NOTIFY LOCAL FIRE DEPARTMENT OF WORK IN ADVANCE (FIRE HYDRANT LOCATED NEXT TO POLE).
NOTE: SCL/SPOTTER TO ASSIST PEDESTRIAN & LOCAL TRAFFIC.
Adjust sign spacing per
MUTCD and site conditions.
FOOTPRINT OF
WORK ZONE:
10’ X 250’UTILITYWORKAHEADABUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (MPH) 25 30 35 40 45 50 55 60 65 70
LENGTH(FEET) 155 200 250 305 360 425 495 570 645 730
PROTECTIVE VEHICLE WITH TMA ROLL AHEAD DISTANCE
TYPICAL PROTECTIVE TYPICAL PROTECTIVE VEHICLE STATIONARY
VEHICLE TYPE (WITH TMA) LOADED WEIGHT OPERATION
WITH TMA (LBS) (FEET)
4 YARD DUMP TRUCK. MINIMUM WEIGHT 15,000 LBS
SERVICE TRUCK (MAXIMUM WEIGHT SHALL BE
FLAT BED. ETC. IN ACCORDANCE WITH
MANUFACTURER RECOMMENDATION
30 MIN
ROLL AHEAD STOPPING DISTANCE ASSUMES DRY PAVEMENT
*A PROTECTIVE VEHICLE IS RECOMMENDED REGARDLESS IF
TMA IS AVAILABLE. IF NO TMA IS USED, THE PROTECTIVE VEHICLE
SHALL BE STRATEGICALLY LOCATED IN THE FIELD TO SHIELD
WORKERS AND NO ROLL AHEAD DISTANCE IS SPECIFIED.
ROAD CLASS DEFINITIONS
CLASS I - Central Business, University District
CLASS II - Arterial Streets,
CLASS III - All partially or full controlled access arterial streets
*Advanced warning signs if feasible
** Vertical barricades, cones, tubular guideposts
CHANNELIZING DEVICE SPACING (FEET)
MPH TAPER TANGENT
50/65 40 80
35/45 30 60
25/30 20 40
LANE
WIDETH
(FEET)25 30 35 40 45 50 55 60 65 70
Posted Speed (mph)
- - - 270 450 500 550 - - -
- - - 295 495 550 605 660 - -
- - - 320 540 600 720 780 840 -
10
11
12
MINIMUM TAPER LENGTH = L (FEET)
S
MFP19005588