Loading...
HomeMy WebLinkAboutR-3978210 11)/4w DOORS O.D. CLEAR OPENING rBOLT DOWN LOCKING 1 (2) - J2"0 HEX BOLTS / 77 771-7-/7 7 77 771-7-/ YE A L1 /1/L/L/ /L/,4 717-/T/ 77 771-7-/7—/ 77 to !] O `v of A N No. 25P SUITABLE FOR H-20 WHEEL GALVANIZE DIAMOND PLATE LOAD IN OFF-STREET LOCATIONS DOORS W/LOCKING BOLTS WHERE NOT SUBJECTED TO HIGH DENSITY TRAFFIC PLAN VIEW WO INSERT W/HEX BOLT 1Y2"0 LIFT HOLE (2 EACH SIDE) (1 EACH SIDE) =JL� �, ADJUSTMENT 2' 4' i 4'-O" LONG GALVANIZED "C" CHANNEL (1 EACH SIDE) L LENGTH 10' WIDE KNOCK, IN FLOOR FOR INTERCEPTS SECTION A —A FIELD GROUT --------------- - — r — — — — — — — — — — —I- ------------ 5Y2"x10" BLOCKOUT i1 (1 EACH END) Fl DETAIL 1: 25—TA COMMUNICATIONS VAULT DETAILS NOT TO SCALE �goAK7 Gay wnsgr '+,/a FEDAID: CM-1292(002) 'ti ti�7 719 Second Ave., Suite 1250 F RECORD DR]tio. CALL 48 HOURS ' Seattle, Washing ton 98104 mformodon shown on thls — 3 describes o designed compo BEFORE YOU DIG Izosl aaz-s zoo a E4 on- —anted norm hems. SSr �ti regarding a n- t eted comRECORD DRAWING WNM1VAksassodates.cofn ONAL /14 provided by others and was 1-800-424-55555 N0. REVISION END VIEW BY I DATE I APPR I sr -- ING FROM RACKING HARDWARE ARD PLAN J-90.20 FOR TRUNK SPLICES, COIL HALF OF THE FIBER CABLE PRIOR TO ENTERING SPLICE ENCLOSURE. SEE PLANS FOR SLACK QUANTITY TO BE STORED SEE PLANS FOR NUMBER AND SIZE OF CABLES FIBER SPLICE ENCLOSURE PLACED TO MAXIMIZE FIBER BEND RADIUS. DETAIL 2: FIBER SPLICE ENCLOSURE AND CABLE STORAGE DETAIL NOT TO SCALE EXISTING CONDUIT DETAIL 3: FIBER OPTIC INSTALLATION DETAIL NOT TO SCALE GENERAL NOTES: 1. PROVIDE NON-SKID COVERS FOR LIDS WITH LOCKING BOLTS AND MARK WITH 'ITS' USING 3" HIGH LETTERING. THE LABEL SHALL BE STAMPED OR WELDED ON THE COVER. 2. ALL CONDUITS ARE TO BE MANDREL -PROOFED PER WSDOT SPECIFICATIONS. 3. UTILITY VAULT SHALL MEET ASTM C 478 WITH TWENTY-EIGHT (28) DAY 550OPSI MINIMUM COMPRESSIVE STRENGTH CONCRETE. 4. VAULT COVER SHALL HAVE A SLIDE -LOCK DEVICE AND GROUND STRAP. 5. VAULTS SHALL BE SUPPLIED WITH HARDWARE MOUNTING RACK FOR CABLE STORAGE AND MOUNTING OF THE SPLICE CASE. 6. VAULTS SHALL BE CONFIGURED SUCH THAT THE TENSILE AND BENDING LIMITATIONS OF THE FIBER OPTIC CABLE ARE NOT COMPROMISED. VAULTS SHALL BE CONFIGURED TO MECHANICALLY PROTECT THE FIBER OPTIC CABLE AGAINST INSTALLATION FORCE AS WELL AS INERT FORCES AFTER CABLE PULLING OPERATIONS. Approved For Bid Robert M. Hanson P.E. Date na�=o� °�=�,ae, CITY 0 F 1. — 10, uLn� (811RENTON I o�ExCx I Public Works Department INTERCONNECT DATUM Approved For Construction COMMUNICATION VAULT D ETA I Robert M. Hanson P.E. Date SD-1