Loading...
HomeMy WebLinkAboutR-398122LT LO O ui E 0 z 13 J ,_. E w 0 I N JUNCTION BOX SIZED PER TRAFFIC SIGNAL AND ILLUMINATION PLANS. LABEL JUNCTION BOX LIDS AS SHOWN (TYP.) - 10'- 0 " STEEL CONDUIT SECTION BETWEEN CONDUIT DEFLECTION FITTING A AND PVC CONDUIT IN CTAT11-MIA V CnOAA QA001C-0 LT THRIE BEAM OR W-BEAM GUARDRAIL 10'-0" MIN. TO 20'-0" MAX. END OF BRIDGE OR WALL STAINLESS STEEL COVER SCREWS (TYP.) SECURE CONDUIT AND BOX TO REBAR TO PREVENT MOVEMENT—, CONDUIT DEFLECTION FITTING A SEE DETAIL THIS SHEET N 10' STEEL CONDUITS STEEL CONDUIT TO PVC ADAPTORS IN STATIONARY FORM BARRIER WHERE PVC PIPE INSTALLED IN BARRIER LT ffl��&AA AM 91AF� %P CONDUIT EXPANSION FITTING (TYP. AT EXPANSION JOINT IF NECESSARY) INSIDE BARRIER FACE JUNCTION BOX & PULL BOX (TYP.) NEMA 4X STAINLESS STEEL WITH BOLT -ON LID OR EQUAL. SEE TRAFFIC SIGNAL AND ILLUMINATION PLANS FOR POLE LOCATION TYPICAL AT END OF MODIFIED PEDESTRIAN BARRIER END SECTION WHERE THRIE BEAM END SECTION "DESIGN F" STD. PLAN C-7o � JUNCTION BOX &BARRIER PANEL OR GUARDRAIL END SECTION "DESIGN D OR F" STD PLAN C-7 /S USED. FOR C.O.R. ILLUMINATION � JUNCTION BOX &BARRIER PANEL FOR WSDOT ILLUMINATION _(C.O.R.) �- BLOCKOUI I -OH L—STEEL CONDUIT TO PVC ADAPTOR IN CONDUITS STATIONARY FORM BARRIER WHERE CONDUIT DEFLECTION PVC PIPE INSTALLED IN BARRIER FITTING A STEEL CONDUIT SECTION BETWEEN CONDUIT DEFLECTION FITTING A AND JUNCTION BOX J'- 0 " LONG EXPANDED POLYSTYRENE SLEEVE AROUND CONDUIT. DUCT TAPE SEAMS AND ENDS TO SEAL AND PREVENT CONCRETE FROM BONDING WITH FITTING AND CONDUIT —\ CONDUIT PIPE SIZED PER WIRING SCHEDULE ° ° °'` ' ° \1 EXPANSION JOINT CONDUIT EXPANSION FITTING ' [44 ° , ° ° , ° ° 1 , 77''''', '° , , ° °,°,° . ° , BONDING JUMPER 1 " TIES N SPACE @ 2,9" MAX. CONDUIT EXPANSION FITTING CONDUIT FITTING - (TYPE AX FOR MOVEMENT OF -± 2'> AT BRIDGE EXPANSION JOINTS IF NECESSARY BUNDLE FB-11 #5 OR 38 #5 ADJACENT TO EACH END OF JUNCTION BOX (TYP.) 114 x J'-6" (TYP.) EL EVA TION 1 iTvo � -----1-1----- ` L — — — — — — — — — — — — — ---------- — — — — — — — — — :::::::-------- ::------------- --- —--—————————————————————————— — — — — —— we wAk 0=4 .1 M-0-, ff-M MP0,Md, MOMM"• k -3�11 � �� LABEL JUNCTION BOX COVER IN ACCORDANCE WITH STANDARD SPECIFICATION 9-29.2(4) AND SPECIAL PROVISIONS. ADJACENT JUNCTION BOXES ARE SHOWN CENTERED BETWEEN ADJACENT DUMMY JOINTS. IF THE DISTANCE BETWEEN ADJACENT DUMMY JOINTS IS 16'-0" OR GREATER, PLACE ADJACENT JUNCTION BOXES SYMMETRICALLY ON EITHER SIDE OF THE CENTER OF ONE DUMMY PANEL WHILE MAINTAINING 8'-0" MINIMUM BETWEEN CENTER LINES OF THE JUNCTION BOXES. " PREMOLDED JOINT FILLER ZtCONDUIT SIZE PER WIRING SCHEDULE START WHERE CONDUIT IN ASTRUCTURE /S ROUTED n ricuv�v�uc� �virvi cic ACROSS A JOINT, WRAP STEEL CONDUIT PIPE SEE STANDARD PLANS WHERE CONDUIT /N A STRUCTURE IS ROUTED �,,,, ,, ,,,, ,,,, �.,,,, ,.,,,� „� ,,,,.,_ ,,,,,� ,.,,,.,, CONCRETE CONCRETEACROSS A JOINT, WRAP STEEL CONDUIT PIPE SECTION B FOR 1 -0 ON EACH SIDE OF JOINT. PIPE WRAP TAPE SHALL BE 2" WIDE, 20 MIL THICK, AND INSTALLED WITH A MINIMUM OF 1 " OVERLAP —7 • .o .c.•o:Po J" MIN., 6" MAX. (CONDUIT AND THREADS CAST OUTSIDE STRUCTURE) CONDUIT DEFLECTION FITTING WITH INTERNAL BONDING JUMPER V � e .o,.. D...D •ee• �% CONDUIT PIPE CONDUIT DEFLECTION FITTING A CONDUIT FITTING - TYPE DX FOR DEFLECTION OF JOo AND 3/4" MOVEMENT. PLACE AT CONDUIT PIPE EXIT FROM STRUCTURE 1" TIES @ 2 1" 4 vi �4. G ^•vve v -y— �� jai`'+�.1i . 4 . .a FOR 1'-0" ON EACH SIDE OF JOINT. PIPE WRAP TAPE SHALL BE 2 " WIDE, 20 MIL. THICK, 3/4 " POLYSTYRENE FOAM. WRAP 1 X TIMES AROUND CONDUIT AND CONDUIT FITTING END AND INSTALLED WITH A MINIMUM OF 1 " 2 N STAINLESS STEEL OVERLAP MOUNTING TABS (TOP & BOT.) BUNDLE 2 B 15 DR 2 B8 115 JUNCTION BOX N 8 " x 8 " x 18 " NEMA 4X IN ADJACENT TO EACH END OF STATIONARY FORM BARRIER, ADJUSTABLE NEMA JUNCTION BOX (TYP.) JR IN SLIP FORM BARRIER. JUNCTION BOX CAN I BE RECESSED UP TO %8 ". 3/8 "0 POLYETHYLENE CONDUIT PIPE OR COPPER PIPE DRAIN CONDUIT DEFLECT/ON FITTING B CONDUIT FITTING - TYPE DX FOR DEFLECTION OF JO* AND 3/4- MOVEMENT. CONDUIT PIPES PLACED THROUGH RETAINING WALL PEDESTRIAN BARRIER SHALL BE FITTED WITH DEFLECTION FITTINGS AT A MAXIMUM SPACING OF 120'. THE DEFLECTION FITTINGS SHALL BE PLACED AT THE PEDESTRIAN BARRIER OPEN JOINT THAT COINCIDES WITH THE RETAINING WALL STEM EXPANSION JOINT NEAREST TO THE TRANSVERSE CONSTRUCTION JOINT IN THE WALL FOOTING. SECTION (o'A SURVEYED: JFSDRAWING NO. 4.05 DRAWN BY: XYW �4 pF "fir t CITY OF RENTON HIGHLANDS TO LANDING `� �� '�' ►.Il PROJECT NO. 31796 DESIGN BY: XYW Public works Department PEDESTRIAN CONNECTION PROJECT CM-1070(007) CHECK BY: SJW HanmiGlobal Partner A , FED AID NO. CM-1070(007) 10230 NE Points Drive APPRO D F R CONSTRUCTION PEDESTRIAN BARRIER DETAILS 3 OF 3 DATE: June. 2013 Suite 400 0 4.5633 ti� PROJ MGR: LBM mod, ssshin&n 9 *&Jt 4� Phone: (425) 822-447 •L s �� � ��� BY: DATE:001�1 SHEET NO. 18 OF 44 NUMBER REVISION DESCRIPTION BY APP. DATE FAX: (425) k.com 77 jONAL �nn►.otak.com