HomeMy WebLinkAboutR-398133J
E
CONSTRUCTION NOTES
O1 CONSTRUCT CITY PEDESTRIAN —SCALE LUMINAIRE POLE FOUNDATION PER COR STD PLAN 117.2. FURNISH AND INSTALL CITY
PEDESTRIAN —SCALE POLE, ARM, LUMINAIRE, AND ALL ASSOCIATED EQUIPMENT PER THE POLE SCHEDULE DRAWING 6.04, THE PROJECT
SPECIFICATIONS, AND COR STD. PLANS 117.2 AND 117.3. APPLY DECAL NUMBERING WITH COR POLE ID PER THE POLE CHART AND
COR STD PLAN 121.
O EXISTING LUMINAIRE POLE TO REMAIN.
O ADJUST EXISTING JUNCTION BOX TO FINISHED GRADE AS NEEDED. EXTEND NEW CONDUIT TO EXISTING JUNCTION BOX.
O4 CONSTRUCT SERVICE CABINET FOUNDATION PER COR STD PLAN 126.2. FURNISH AND INSTALL SERVICE CABINET PER COR STD PLAN
122.1. LOCATION AND ORIENTATION OF FOUNDATION AND CABINET SHALL BE VERIFIED BY CITY OF RENTON INSPECTOR PRIOR TO
INSTALLATION OF CONDUITS.
OAPPROXIMATE POWER CONNECTION POINT. CONTRACTOR SHALL PROVIDE CONDUIT TO UTILITY POLE PER THE WIRING SCHEDULE.
CONTRACTOR SHALL COORDINATE WITH PSE FOR SPECIFIC REQUIREMENTS. PSE TO PROVIDE 120/240 VOLT SINGLE PHASE POWER
SOURCE. CONTRACTOR SHALL COORDINATE WITH PSE FOR SERVICE CABINET ELECTRICAL HOOK—UP, SHALL PREPARE/SUBMIT ALL
APPLICABLE PERMITS, AND SHALL PAY ALL ASSOCIATED FEES.
�6 SEE DRAWINGS 4.03, 4.05, AND 4.08 FOR CONDUIT AND JUNCTION BOX INSTALLATION DETAILS ON BRIDGE DECK.
O7 RELOCATE EXISTING LUMINAIRE POLE ONTO NEW BRIDGE STRUCTURE PER DRAWING 4.08.
OFURNISH AND INSTALL CITY PEDESTRIAN —SCALE POLE, ARM, LUMINAIRE, AND ALL ASSOCIATED EQUIPMENT PER THE POLE SCHEDULE
DRAWING 6.04, THE PROJECT SPECIFICATIONS, AND COR STD. PLANS 117.2 AND 117.3. APPLY DECAL NUMBERING WITH COR POLE ID
PER THE POLE CHART AND COR STD PLAN 121. MOUNT TO BRIDGE STRUCTURE PER DRAWING 4.08.
O INSTALL 6' DIA. TYPE 3 LOOP DETECTOR PER WSDOT STANDARD PLAN J-50.12.
10 RELOCATE EXISTING WSDOT LUMINAIRE POLE PER THE POLE CHART, DRAWING 6.04. REMOVE EXISTING FOUNDATION AND CONDUIT.
11 RELOCATE EXISTING JUNCTION BOX OUTSIDE SIDEWALK. INTERCEPT AND EXTEND EXISTING CONDUIT.
12 PROTECT AND MAINTAIN EXISTING LOOP DETECTOR.
13 EXTEND CONDUIT TO EXISTING JUNCTION BOX.
14 INSTALL TYPE APS PEDESTRIAN PUSHBUTTON TO EXISTING POLE, REMOVE EXISTING PUSHBUTTON AND REPAIR HOLE PER WSDOT
APPROVED —METHOD. SALVAGED EQUIPMENT BECOMES PROPERTY OF WSDOT.
15 INSTALL NEW FOUNDATION PER WSDOT STANDARD PLAN J-21.10. RELOCATE EXISTING PS POLE, PEDESTRIAN HEAD AND PUSHBUTTON
TO NEW FOUNDATION. REMOVE EXISTING FOUNDATION TO MINIMUM 24" BELOW FINISH GRADE. FILL AND COMPACT VOID.
Cp
I
PARK
AVE
NIII
V L52
(L23
SIGNAL STANDARD DETAIL CHART
STD.
FOUNDATION
REFERENCE
FIELD LOCATION
TYPE
DEPTHS(FT)
REMARKS
ROADWAY
STATION
I OFFSET
LT.
RT.
P.O.A.
3' RD.
3' SO
4' RD.
F7
NE PARK DR
5,3+57.0
65.5
JX�
0°
PS
--
--
--
FDN PER WSDOT
STD J-20.10
GENERAL CONSTRUCTION NOTES
1. AS PART OF THE DESIGN PROCESS, THE ENGINEER HAS ATTEMPTED TO CONFIRM THAT THERE
ARE NOT CONFLICTS WITH OVERHEAD POWER LINES OR SUBSURFACE UTILITIES. HOWEVER, IT
IS POSSIBLE FOR THE EXISTING OR PROPOSED CONDITIONS TO CHANGE PRIOR TO
IMPLEMENTATION OF THE SCOPE OF WORK IDENTIFIED ON THESE DOCUMENTS. AS THE FIRST
ORDER OF BUSINESS THE CONTRACTOR SHALL POTHOLE EACH NEW LUMINAIRE POLE LOCATION
TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH SUBSURFACE UTILITIES. ADDITIONALLY,
THE CONTRACTOR SHALL CONFIRM THAT THERE IS A MINIMUM 10—FT CLEARANCE PROVIDED
BETWEEN OVERHEAD POWER LINES AND THE PROPOSED LUMINAIRE POLES PRIOR TO POLE
PLACEMENT. ADDITIONAL CLEARANCE MAY BE REQUIRED AS DIRECTED BY THE UTILITY. THE
CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY IF A CONFLICT IS DISCOVERED.
/WA.
4
L,45 z
�4
ILLUMINATION CRITERIA
1.0 FOOT CANDLES
4:1 UNIFORMITY
0.72 LIGHT LOSS FACTOR
SEE DRAWING 6.04 FOR
STREET LIGHTING
ILLUMINATION POLE
SCHEDULE
CITY SYSTEM - BREAKER SCHEDULE (SERVICE #1)
CIRCUIT
BREAKER
CONTACTOR
ILLUM A
2P-20 AMP
30 AMP
ILLUM B (SPARE)
2P-20 AMP
30 AMP
ILLUM C (SPARE)
2P-20 AMP
30 AMP
w!�1
ILLUMINATION WIRING SCHEDULE
RACEWAY CONDUIT SIZE
ILLUM.
#8
EQUIP.
GRND.
#8
SVC
PWR
#2
2C(SH)
LOOP
PULL
WIRE
CONDUIT
FILL
ALLOW.
FILL
(26%)
ALLOW.
FILL
(40%)
NO.
EX.
NEW
EX.
NEW
EX.
NEW
EX.
NEW
EX.
NEW
1
2" NEW SCH 40 CITY
2
1
0.17
0.86
---
2
2" NEW RGS CITY
2
1
0.17
0.89
---
3
3' NEW RGS CITY
3
0.94
1.95
---
4
2" NEW SCH 40 WSDOT
2
1
0.17
0.86
— — —
5
2" EX WSDOT
2
1
1
0.17
0.86
— — —
6
2 NEW RGS WSDOT
2
0.17
0.86
---
7
2 NEW SCH 40 WSDOT
3
0.27
0.86
---
8
4 NEW SCH 40 SPARE ITS
1
---
3.35
---
9
4" NEW RGS SPARE ITS
1
---
3.35
---
U1 1 Y SY51 LM - ILLUMINAI IUN WIKINV UTAVKAM (SERVILE #1 )
PARK/LWB SERVICE (#1)
NEW LUMINAIRE
(TYP.)
ILLUM SPARE
BRIDGE DECK I NE PARK DR
R/W
LEGEND
EXIST.
NEW/RELOCATED
DESCRIPTION
Ei z 0-i
m 0 [11
JUNCTION BOX TYPE 1,2,8
NEMA JUNCTION BOX
-
VEHICLE SIGNAL HEAD
-- ---t�'
PEDESTRIAN SIGNAL HEAD
®
SIGNAL POLE TYPE III
SIGNAL POLE TYPE II
O
O
TYPE PS POLE
-
NON—APS PPB
APS PPB
(�
LOOP DETECTION TYPE 3
VIDEO DETECTION ZONE
--- — — —
-----
CONDUIT
MAST ARM MOUNTED SIGN
EMERGENCY PRE—EMPTION
DETECTOR
f--
WSDOT ROAD —SCALE POLE
®
CITY PED.—SCALE POLE
CONTROLLER CABINET
®
SERVICE CABINET
OCONSTRUCTION
NOTE
®
SIGNAL POLE NUMBER
O
CITY PED.—SCALE POLE
NUMBER
WSDOT ROAD —SCALE POLE
NUMBER
WIRE NOTE
20
SCALE IN FEET
NER T SURVEYED:
4p DRAWING NO. 6.01
���;.•oF'wgs°••�% DRAWN BY:19TENW CITY OF RENTON HIGHLANDS TO LANDING
�Jl PROJECT NO. 31796
• - DESIGN BY: Transportation Engineering NorfhWest — Public Works Department PEDESTRIAN CONNECTION PROJECT CM-1070(007)
FED AID NO. CM-1070(007)
aL °•� CHECK BY: Transportation Planning I Design I Traffic Impact & Operations TRAFFIC SIGNAL AND ILLUMINATION PLAN 356 ;'� p g APPROVED FOR CONSTRUCTION DATE: June 2013
F ••• �� STEM • G\ PROD MGR: PO Box 65254, Seattle, WA 98155 1 Office (206) 361-7333
SS�OiVAL • �, I� Project Contact: Chris Bicket, P.E.
NUMBER REVISION DESCRIPTION BY APP. DATE Phone:425-250-5002 BY: DATE: � //� SHEET NO. 27 OF 44