HomeMy WebLinkAboutR-3981353 a z ry Cn 'v O i 0 a i 0 E _ a X X 1 N 0 I 0 N i v Z _ V) i X X X 1 12 .o 0 c i 0 0 '.7 SEPARATE WSDOT / ILLUM. SYSTEM CONDUIT GABION WALL (10" —' MIN VERT. 699 CLEARANCE BETWEEN WALL AND CONDUIT) DETAIL - PEDESTRIAN POLE BEHIND WALL SCALE: N.T.S. CONSTRUCTION NOTES 1 CONSTRUCT CITY PEDESTRIAN —SCALE LUMINAIRE POLE FOUNDATION PER COR STD PLAN 117.2. FURNISH AND INSTALL CITY PEDESTRIAN —SCALE POLE, ARM, LUMINAIRE, AND ALL ASSOCIATED EQUIPMENT PER THE POLE SCHEDULE DRAWING 6.04, THE PROJECT SPECIFICATIONS, AND COR STD. PLANS 117.2 AND 117.3. APPLY DECAL NUMBERING WITH COR POLE ID PER THE POLE CHART AND COR STD PLAN 121. O2 EXISTING LUMINAIRE POLE TO REMAIN. O3 ADJUST EXISTING JUNCTION BOX TO FINISHED GRADE AS NEEDED. EXTEND NEW CONDUIT TO EXISTING JUNCTION BOX. 4 CONSTRUCT SERVICE CABINET FOUNDATION PER COR STD PLAN 126.2. FURNISH AND INSTALL SERVICE CABINET PER COR STD PLAN 122.1. LOCATION AND ORIENTATION OF FOUNDATION AND CABINET SHALL BE VERIFIED BY CITY OF RENTON INSPECTOR PRIOR TO INSTALLATION OF CONDUITS. OAPPROXIMATE POWER CONNECTION POINT. CONTRACTOR SHALL PROVIDE CONDUIT TO UTILITY POLE PER THE WIRING SCHEDULE. CONTRACTOR SHALL COORDINATE WITH PSE FOR SPECIFIC REQUIREMENTS. PSE TO PROVIDE 120�/240 VOLT SINGLE PHASE POWER SOURCE. CONTRACTOR SHALL COORDINATE WITH PSE FOR SERVICE CABINET ELECTRICAL HOOK—UP, SHALL PREPARE/SUBMIT ALL APPLICABLE PERMITS, AND SHALL PAY ALL ASSOCIATED FEES. O6 SEE DRAWINGS 4.03, 4.05, AND 4.08 FOR CONDUIT AND JUNCTION BOX INSTALLATION DETAILS ON BRIDGE DECK. �7 RELOCATE EXISTING LUMINAIRE POLE ONTO NEW BRIDGE STRUCTURE PER DRAWING 4.08. OFURNISH AND INSTALL CITY PEDESTRIAN —SCALE POLE, ARM, LUMINAIRE, AND ALL ASSOCIATED EQUIPMENT PER THE POLE SCHEDULE DRAWING 6.04, THE PROJECT SPECIFICATIONS, AND COR STD. PLANS 117.2 AND 117.3. APPLY DECAL NUMBERING WITH COR POLE ID PER THE POLE CHART AND COR STD PLAN 121. MOUNT TO BRIDGE STRUCTURE PER DRAWING 4.08. �9 INSTALL 6' DIA. TYPE 3 LOOP DETECTOR PER WSDOT STANDARD PLAN J-50.12. TOP OF O RELOCATE EXISTING WSDOT LUMINAIRE POLE PER THE POLE CHART, DRAWING 6.04. REMOVE EXISTING FOUNDATION AND FOUNDATION TO 10 CONDUIT. MATCH SIDEWALK FINISH GRADE 11 RELOCATE EXISTING JUNCTION BOX OUTSIDE SIDEWALK. INTERCEPT AND EXTEND EXISTING CONDUIT. 12 PROTECT AND MAINTAIN EXISTING LOOP DETECTOR. 8FT MINIMUM 13 FOUNDATION DEPTH EXTEND CONDUIT TO EXISTING JUNCTION BOX. 14 INSTALL TYPE APS PEDESTRIAN PUSHBUTTON TO EXISTING POLE, REMOVE EXISTING PUSHBUTTON AND REPAIR HOLE PER WSDOT APPROVED —METHOD. SALVAGED EQUIPMENT BECOMES PROPERTY OF WSDOT. 15 INSTALL NEW FOUNDATION PER WSDOT STANDARD PLAN J-21.10. RELOCATED EXISTING PS POLE, PEDESTRIAN HEAD AND PUSHBUTTON TO NEW FOUNDATION. REMOVE EXISTING FOUNDATION TO MINIMUM 24" BELOW FINISH GRADE. FILL AND COMPACT VOID. FOUNDATION PER COR STD PLAN GENERAL CONSTRUCTION NOTES 117.2 1. AS PART OF THE DESIGN PROCESS, THE ENGINEER HAS ATTEMPTED TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH OVERHEAD POWER LINES OR SUBSURFACE UTILITIES. HOWEVER, IT IS POSSIBLE FOR THE EXISTING OR PROPOSED CONDITIONS TO CHANGE PRIOR TO IMPLEMENTATION OF THE SCOPE OF WORK IDENTIFIED ON THESE DOCUMENTS. AS THE FIRST ORDER OF BUSINESS THE CONTRACTOR SHALL POTHOLE EACH NEW LUMINAIRE POLE LOCATION TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH SUBSURFACE UTILITIES. ADDITIONALLY, THE CONTRACTOR SHALL CONFIRM THAT THERE IS A MINIMUM 10—FT CLEARANCE PROVIDED BETWEEN OVERHEAD POWER LINES AND THE PROPOSED LUMINAIRE POLES PRIOR TO POLE PLACEMENT. ADDITIONAL CLEARANCE MAY BE REQUIRED AS DIRECTED BY THE UTILITY. THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY IF A CONFLICT IS DISCOVERED. ILLUMINATION WIRING SCHEDULE RACEWAY CONDUIT SIZE tLLUM. # g EQUIP. GRND. #8 SVC PWR #2 2C(SH) LOOP PULL WIRE CONDUIT FILL ALLOW. FILL (26%) ALLOW. FILL (40%) NO. EX. NEW EX. NEW EX. NEW EX. INEW EX. NEW 1 2" NEW SCH 40 CITY 2 1 1 1 0.17 0.86 --- 2 2" NEW RGS CITY 2 1 0.17 0.89 --- 3 3' NEW RGS CITY 3 0.94 1.95 --- 4 2" NEW SCH 40 WSDOT 2 1 0.17 0.86 --- 5 2" EX WSDOT 2 0.17 0.86 --- 6 27 NEW RGS WSDOT 2 0.17 0.86 --- 7 2" NEW SCH 40 WSDOT 3 0.27 0.86 --- 8 4" NEW SCH 40 SPARE ITS 1 --- 3.35 --- 9 4" NEW RGS SPARE ITS 1 --- 3.35 --- EXIST. NEW/RELOCATED DESCRIPTION z [I] m 0 [I JUNCTION BOX TYPE 1,2,8 NEMA JUNCTION BOX VEHICLE SIGNAL HEAD PEDESTRIAN SIGNAL HEAD SIGNAL POLE TYPE III s SIGNAL POLE TYPE II O O TYPE PS POLE NON—APS PPB APS PPB LOOP DETECTION TYPE 3 VIDEO DETECTION ZONE CONDUIT MAST ARM MOUNTED SIGN EMERGENCY PRE—EMPTION DETECTOR WSDOT ROAD —SCALE POLE CITY PED.—SCALE POLE CONTROLLER CABINET ® SERVICE CABINET OCONSTRUCTION NOTE OSIGNAL POLE NUMBER © CITY PED.—SCALE POLE NUMBER ❑ WSDOT ROAD —SCALE POLE NUMBER WIRE NOTE 10 40 0 20 60 SCALE IN FEET �pQNER T SURVEYED: t DRAWING NO. 6.02 DRAWN BY: HIGHLANDS TO LANDING %9TENW CITY OF RENT N PROJECT NO. 31796 DESIGN BY: Trans ortation En ineerin Northwest Public Works Department PEDESTRIAN CONNECTION PROJECT CM-1070(007} p Engineering TRAFFIC SIGNAL AND ILLUMINATION PLAN FED AID NO. CM-1070(007) O ••� CHECK BY: Transportation Planning Design Traffic Impact & O erations ,�.•'AF. 356 �•; p tt I g I p p APPROVED FOR CONSTRUCTION DATE: June 2013 FS•'•�� STEM ' G\ s PROJ MGR: PO Box 65254, Seattle, WA 98155 1 Office (206) 361-7333 /�NA1 •�� �•'� Project Contact: Chris Bicket, P.E. 11, SHEET NO. 28 OF 44 NUMBER REVISION DESCRIPTION BY APP. DATE �I'� Phone:425-250-5002 BY: DATE: 7'` f•