HomeMy WebLinkAboutR-3981363
J
Q
z
0
w
Q
.o
0
C
0
i
0
a
U
/
0
0
V)
;_
Q
X
X
I
N
0
I
0
N
0
/
X
X
X
X
I
.o
0
9
0
v
E
0
00
N
CO
I
0
N
0
a
Q
a�
0
d
T
0
DELETE SEPARATE
WSDOT CONDUIT
v
Z
Q
0
w
w
co
0
0
cr
Q
Q
CL
w
z
w
z
J
2
U
H
Q
ILLUMINATION WIRING SCHEDULE
ILLUM. EQUIP. SVC ALLOW. ALLOW.
RACEWAY CONDUIT SIZE #g GRIND. PWR LOOP) WIRE PULL CONDUIT DL IT FILL FILL
N0. #8 #2 (26%) (40%)
DELETE DELETE WSDOT JB EX. NEW EX. NEW EX. NEW EX. NEW EX. NEW
SEPARATE ruor 1 2" NEW SCH 40 CITY 2 1 0.17 0.86 - - -
Fo / 2 2 NEW RGS CITY 2 1 1 0.17 1 0.89 ---
WSDOT 3 3" NEW RGS CITY 3 0.94 1.95 ---
CONDUIT 8 C 4 2" NEW SCH 40 WSDOT 2 1 0.17 0.86 ---
1 7 2 7 8 5 2" EX WSDOT 2 0.17 0.86 ___
•6 2" NEW RGS WSDOT 2 0.17 0.86
6 88 7 2" NEW SCH 40 WSDOT 3 0.27 0.86 ---
2 L
` 2 8 4" NEW SCH 40 SPARE ITS 1 __= 3.35 ___
�� �W 2 9 4" NEW RGS SPARE ITS 1 3.35
rOKICTRIIrTIOKI
CONSTRUCT CITY PEDESTRIAN -SCALE LUMINAIRE POLE FOUNDATION PER COR STD PLAN 117.2. FURNISH AND INSTALL CITY 1Y
PEDESTRIAN -SCALE POLE, ARM, LUMINAIRE, AND ALL ASSOCIATED EQUIPMENT PER THE POLE SCHEDULE DRAWING 6.04, THE
PROJECT SPECIFICATIONS, AND COR STD. PLANS 117.2 AND 117.3. APPLY DECAL NUMBERING WITH COR POLE ID PER THE
POLE CHART AND COR STD PLAN 121.
2O EXISTING LUMINAIRE POLE TO REMAIN.
3O ADJUST EXISTING JUNCTION BOX TO FINISHED GRADE AS NEEDED. EXTEND NEW CONDUIT TO EXISTING JUNCTION BOX.
4 CONSTRUCT SERVICE CABINET FOUNDATION PER COR STD PLAN 126.2. FURNISH AND INSTALL SERVICE CABINET PER COR
STD PLAN 122.1. LOCATION AND ORIENTATION OF FOUNDATION AND CABINET SHALL BE VERIFIED BY CITY OF RENTON
INSPECTOR PRIOR TO INSTALLATION OF CONDUITS.
r O APPROXIMATE POWER CONNECTION POINT. CONTRACTOR SHALL PROVIDE CONDUIT TO UTILITY POLE PER THE WIRING STREET LIGHTING v
SCHEDULE. CONTRACTOR SHALL COORDINATE WITH PSE FOR SPECIFIC REQUIREMENTS. PSE TO PROVIDE 120/240 VOLT LEGEND ILLUMINATION POLE
SINGLE PHASE POWER SOURCE. CONTRACTOR SHALL COORDINATE WITH PSE FOR SERVICE CABINET ELECTRICAL HOOK—UP,
SHALL PREPARE/SUBMIT ALL APPLICABLE PERMITS, AND SHALL PAY ALL ASSOCIATED FEES. EXIST. NEW/RELOCATED DESCRIPTION SCHEDULE
6O SEE DRAWINGS 4.03, 4.05, AND 4.08 FOR CONDUIT AND JUNCTION BOX INSTALLATION DETAILS ON BRIDGE DECK. N N m m 0 I JUNCTION BOX TYPE 1 ,2,8
O7 RELOCATE EXISTING LUMINAIRE POLE ONTO NEW BRIDGE STRUCTURE PER DRAWING 4.08. NEMA JUNCTION BOX
OFURNISH AND INSTALL CITY PEDESTRIAN -SCALE POLE, ARM, LUMINAIRE, AND ALL ASSOCIATED EQUIPMENT PER THE POLE —0 VEHICLE SIGNAL HEAD
SCHEDULE DRAWING 6.04, THE PROJECT SPECIFICATIONS, AND COR STD. PLANS 117.2 AND 117.3. APPLY DECAL
NUMBERING WITH COR POLE ID PER THE POLE CHART AND COR STD PLAN 121. MOUNT TO BRIDGE STRUCTURE PER //-0 PEDESTRIAN SIGNAL HEAD
DRAWING 4.08.
SIGNAL POLE TYPE III
9O INSTALL 6' DIA. TYPE 3 LOOP DETECTOR PER WSDOT STANDARD PLAN J-50.12. •
TOP OF f SIGNAL POLE TYPE II FOUNDATION TO 10 RELOCATE EXISTING WSDOT LUMINAIRE POLE PER THE POLE CHART, DRAWING 6.04. REMOVE EXISTING FOUNDATION AND
CONDUIT. O p TYPE PS POLE
MATCH SIDEWALK NON-APS PPB
— — — FINISH GRADE 11 RELOCATE EXISTING JUNCTION BOX OUTSIDE SIDEWALK. INTERCEPT AND EXTEND EXISTING CONDUIT. T
—III p p l l=1 1=1 1=1 1=1 I -,-C> -_> APS P P B
11=III=III=III=III=III=1 III —III —III —III —II 12 PROTECT AND MAINTAIN EXISTING LOOP DETECTOR.
11=III=III=III=III 1=11 ° 8FT MINIMUM O LOOP DETECTION TYPE 3
FOUNDATION DEPTH
III= III —III —III —III —II III 13 EXTEND CONDUIT TO EXISTING JUNCTION BOX.
I=III III=III=III=III=III I=III
SEPARATE WSDOT HE III—III—III=III=11 III— III— INSTALL TYPE APS PEDESTRIAN PUSHBUTTON TO EXISTING POLE, REMOVE EXISTING PUSHBUTTON AND REPAIR HOLE PER VIDEO DETECTION ZONE
ILLUM. SYSTEM CONDUIT 1-111 II1=111=111=1IMII M11 1-111 = 14 WSDOT III— I I APPROVED —METHOD. SALVAGED EQUIPMENT BECOMES PROPERTY OF WSDOT. I —I I—ICONDUIT
III 1=III=III=III=III ==1 I —III —II INSTALL NEW FOUNDATION PER WSDOT STANDARD PLAN J-21.10. RELOCATED EXISTING PS POLE, PEDESTRIAN HEAD AND
MAST ARM MOUNTED SIGN
PUSHBUTTON TO NEW FOUNDATION. REMOVE EXISTING FOUNDATION TO MINIMUM 24" BELOW FINISH GRADE. FILL AND H
COMPACT VOID. EMERGENCY PRE-EMPTION
=1I1=1II—II1=1I1= =1II III III— �
=1 11= =1 =1 I I I HIM DETECTOR
GABION WALL (10" FOUWSDOT ROAD -SCALE POLE
MIN VERT. 699 COR NDSTD IOPLAN ER GENERAL CONSTRUCTION NOTES CITY PED.—SCALE POLE
CLEARANCE
BETWEEN WALL 117.2 1. AS PART OF THE DESIGN PROCESS, THE ENGINEER HAS ATTEMPTED TO CONFIRM THAT THERE ® CONTROLLER CABINET
AND CONDUIT) ARE NOT CONFLICTS WITH OVERHEAD POWER LINES OR SUBSURFACE UTILITIES. HOWEVER, IT ® ® SERVICE CABINET
DETAIL — PEDESTRIAN IS POSSIBLE FOR THE EXISTING OR PROPOSED CONDITIONS TO CHANGE PRIOR TO
IMPLEMENTATION OF THE SCOPE OF WORK IDENTIFIED ON THESE DOCUMENTS. AS THE FIRST O CONSTRUCTION NOTE
POLE BEHIND WALL ORDER OF BUSINESS, THE CONTRACTOR SHALL POTHOLE EACH NEW LUMINAIRE POLE LOCATION
SCALE: N.T.S. TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH SUBSURFACE UTILITIES. ADDITIONALLY, 0 SIGNAL POLE NUMBER
THE CONTRACTOR SHALL CONFIRM THAT THERE IS A MINIMUM 10-FT CLEARANCE PROVIDED O
BETWEEN OVERHEAD POWER LINES AND THE PROPOSED LUMINAIRE POLES PRIOR TO POLE CITY PED.-SCALE POLE
PLACEMENT. ADDITIONAL CLEARANCE MAY BE REQUIRED AS DIRECTED BY THE UTILITY. THE NUMBER 10 40
CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY IF A CONFLICT IS DISCOVERED. ❑ WSDOT ROAD -SCALE POLE
NUMBER
0 20 60
zn� WIRE NOTE SCALE IN FEET
o®000®O®®
°o SURVEYED:
®®�pQNER..j. 000 �� DRAWING NO. 6.02
'oF•1^'As° •.•ic ®® DRAWN BY: CITY OF RENTON HIGHLANDS TO LANDING
® c?:'� ti� ••. �� ®oo ..11 PROJECT NO. 31796
a DESIGN BY: Transportation Engineering Northwest Public Works Department PEDESTRIAN CONNECTION PROJECT CM-1070(007)
g g FED AID NO. CM-1070(007)
0 �;• .�� ® CHECK BY: Transportation Planning I Design I Traffic Impact & Operations TRAFFIC SIGNAL AND ILLUMINATION P LA N
c•' AFc 56 FZ�;.� �� ® PO Box 65254, Seattle, WA 98155 1 Office (206) 361-7333 APPROVED FOR CONSTRUCTION DATE: June 2013
isTE PROJ MGR:
®®o S�ONAL .�� ®® I Project Contact: Chris Bicket, P.E. SHEET NO. 28 OF 44
NUMBER REVISION DESCRIPTION BY APP. DATE o0oa®®o®®®®®®®® ��� Phone:425-250-5002 BY: DATE: