AS PART OF THE DESIGN PROCESS, THE ENGINEER HAS ATTEMPTED TO CONFIRM THAT THERE
ARE NOT CONFLICTS WITH OVERHEAD POWER LINES OR SUBSURFACE UTILITIES. HOWEVER, IT
IS POSSIBLE FOR THE EXISTING OR PROPOSED CONDITIONS TO CHANGE PRIOR TO
IMPLEMENTATION OF THE SCOPE OF WORK IDENTIFIED ON THESE DOCUMENTS. AS THE FIRST
ORDER OF BUSINESS. THE CONTRACTOR SHALL POTHOLE EACH NEW LUMINAIRE POLE LOCATION
TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH SUBSURFACE UTILITIES. ADDITIONALLY,
THE CONTRACTOR SHALL CONFIRM THAT THERE IS A MINIMUM 10-FT CLEARANCE PROVIDED
BETWEEN OVERHEAD POWER LINES AND THE PROPOSED LUMINAIRE POLES PRIOR TO POLE
PLACEMENT. ADDITIONAL CLEARANCE MAY BE REQUIRED AS DIRECTED BY THE UTILITY. THE
CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY IF A CONFLICT IS DISCOVERED.
CITY SYSTEM - ILLUMINATION POLE SCHEDULE
POLE
STREET
STATION
OFFSET
MOUNT.
ARM
SERVICE/
WATTAGE
LUMINAIRE AND ARM
BASE
POLE / FOUNDATION TYPE
COR ID
HEIGHT
LENGTH
CIRCUIT
/TYPE
TYPE
O1
NE PARK DR
53+73.5
62.5' LT
14'
4'
SERVICE #1
60W30LED
LUMEC PER PROJECT
FIXED
HAPCO PER PROJECT SPECS,
ILLUM A
SPECS
FDN PER DRAWING 6.02
O2
NE PARK DR
54+45.5
56.0' LT
14'
4'
SERVICE #1
60W30LED
LUMEC PER PROJECT
FIXED
HAPCO PER PROJECT SPECS,
ILLUM A
SPECS
FDN PER DRAWING 6.02
O3
NE PARK DR
55+20.5
55.0' LT
14'
4'
SERVICE #1
60W30LED
LUMEC PER PROJECT
FIXED
HAPCO PER PROJECT SPECS,
ILLUM A
SPECS
FDN PER DRAWING 6.02
O4
NE PARK DR
55+96.0
53.0' LT
14'
4'
SERVICE #1
60W30LED
LUMEC PER PROJECT
FIXED
HAPCO PER PROJECT SPECS,
ILLUM A
SPECS
FDN PER DRAWING 6.02
NE PARK DR
56+72.5
50.5 LT
14'
4'
SERVICE #1
60W30LED
LUMEC PER PROJECT
FIXED
HAPCO PER PROJECT SPECS,
ILLUM A
SPECS
FDN PER DRAWING 6.02
O6
NE PARK DR
57+40.5
41.5 LT
14'
4'
SERVICE #1
60W30LED
LUMEC PER PROJECT
FIXED
HAPCO PER PROJECT SPECS,
ILLUM A
SPECS
FDN PER DRAWING 6.02
O7
NE PARK DR
58+11.5
BRIDGE LT
14'
4
SERVICE #1
60W30LED
LUMEC PER PROJECT
FIXED
HAPCO PER PROJECT SPECS,
ILLUM A
SPECS
FDN PER DRAWING 6.02
O
NE PARK DR
58+83.5
BRIDGE LT
14'
4'
SERVICE #1
60W30LED
LUMEC PER PROJECT
FIXED
HAPCO PER PROJECT SPECS,
ILLUM A
SPECS
FDN PER DRAWING 6.02
O9
NE PARK DR
59+54.5
BRIDGE LT
14'
4'
SERVICE #1
60W30LED
LUMEC PER PROJECT
FIXED
HAPCO PER PROJECT SPECS,
ILLUM A
SPECS
FDN PER DRAWING 6.02
10
NE PARK DR
60+22.5
50.0' LT
14'
4'
SERVICE #1
60W30LED
LUMEC PER PROJECT
FIXED
HAPCO PER PROJECT SPECS,
ILLUM A
SPECS
FDN PER DRAWING 6.02
11
NE PARK DR
60+98.5
56.0' LT
14'
4'
SERVICE #1
60W30LED
LUMEC PER PROJECT
FIXED
HAPCO PER PROJECT SPECS,
ILLUM A
SPECS
FDN PER DRAWING 6.02
12
NE PARK DR
61 +77.5
61 LT
14'
4'
SERVICE #1
60W30LED
LUMEC PER PROJECT
FIXED
HAPCO PER PROJECT SPECS,
.5'
ILLUM A
SPECS
FDN PER DRAWING 6.02
13
NE PARK DR
62+31.5
66.5' LT
14'
4'
SERVICE #1
60W30LED
LUMEC PER PROJECT
FIXED
HAPCO PER PROJECT SPECS,
ILLUM A
SPECS
FDN PER DRAWING 6.02
14
NE PARK DR
62+96.5
77.0' LT
14'
4'
SERVICE #1
60W30LED
LUMEC PER PROJECT
FIXED
HAPCO PER PROJECT SPECS,
ILLUM A
SPECS
FDN PER DRAWING 6.02
15
NE PARK DR
64+25.5
58.0' LT
14'
4'
SERVICE #2
60W30LED
LUMEC PER PROJECT
FIXED
HAPCO PER PROJECT SPECS,
ILLUM A
SPECS
FDN PER DRAWING 6.02
16
NE PARK DR
64+74.0
50.5' LT
8'
4'
SERVICE #2
60W30LED
LUMEC PER PROJECT
FIXED
HAPCO PER PROJECT SPECS,
ILLUM A
SPECS
JERSEY -BARRIER MOUNTED
17
NE PARK DR
65+45.0
50.5' LT
8'
4'
SERVICE #2
60W30LED
LUMEC PER PROJECT
FIXED
HAPCO PER PROJECT SPECS,
ILLUM A
SPECS
JERSEY -BARRIER MOUNTED
18
NE PARK DR
66+02.0
50.5' LT
8'
4'
SERVICE #2
60W30LED
LUMEC PER PROJECT
FIXED
HAPCO PER PROJECT SPECS,
ILLUM A
SPECS
JERSEY -BARRIER MOUNTED
19
NE PARK DR
66+87.5
59.5' LT
14'
4'
SERVICE #2
60W30LED
LUMEC PER PROJECT
FIXED
HAPCO PER PROJECT SPECS,
ILLUM A
SPECS
FDN PER DRAWING 6.02
20
NE PARK DR
67+78.5
59.5' LT
14'
4'
SERVICE #2
60W30LED
LUMEC PER PROJECT
FIXED
HAPCO PER PROJECT SPECS,
ILLUM A
SPECS
FDN PER DRAWING 6.02
21
NE PARK DR
68+70.5
59.5' LT
14'
4'
SERVICE #2
60W30LED
LUMEC PER PROJECT
FIXED
HAPCO PER PROJECT SPECS,
ILLUM A
SPECS
FDN PER DRAWING 6.02
22
NE PARK DR
69+45.0
60.0' LT
14'
47
SERVICE #2
60W30LED
LUMEC PER PROJECT -F-FIXED
HAPCO PER PROJECT SPECS,
ILLUM A
SPECS
FDN PER DRAWING 6.02
SERVICE #2
88
CONSTRUCTION NOTES
ILLUMINATION WIRING DIAGRAM (SERVICE #2)
NEW JUNCTION
BOX (TYP.) ILLUM A NE PARK DR
2-#8
ILLUM A
ILLUM B SPARE
ILLUM C SPARE
15 16 17 18 19 20 21 22
NEW LUMINAIRE
(TYP.)
CITY SYSTEM - BREAKER SCHEDULE (SERVICE #2)
CIRCUIT
BREAKER
CONTACTOR
ILLUM A
2P-20 AMP
30 AMP
ILLUM B (SPARE)
2P-20 AMP
30 AMP
ILLUM C (SPARE)
2P-20 AMP
30 AMP
ILLUMINATION WIRING SCHEDULE
RACEWAY CONDUIT SIZE
ILLUM.
#8
EQUIP.
GRND.
#8
SVC
PWR
#2
2C(SH)
LOOP
PULL
WIRE
CONDUIT
FILL
ALLOW.
FILL
(26%
ALLOW.
FILL
(40%)
NO.
EX.
NEW
EX.
NEW
EX.
NEW
EX.
NEW
EX.
NEW
1
2" NEW SCH 40 CITY
2
1
0.17
0.86
---
2
2" NEW RGS CITY
2
1
0.17
0.89
---
3
3" NEW RGS CITY
3
0.94
1.95
---
4
2" NEW SCH 40 WSDOT
2
1
0.17
0.86
---
5
2" EX WSDOT
2
1
0.17
0.86
- - -
6
2" NEW RGS WSDOT
2
0.17
0.86
- - -
7
2" NEW SCH 40 WSDOT
3
0.27
0.86
- - -
8
4" NEW SCH 40 SPARE ITS
1
- - -
3.35
- - -
9
4" NEW RGS SPARE ITS
1
- - -
3.35
---
1 CONSTRUCT CITY PEDESTRIAN -SCALE LUMINAIRE POLE FOUNDATION PER COR STD PLAN 117.2. FURNISH AND INSTALL CITY
PEDESTRIAN -SCALE POLE, ARM, LUMINAIRE, AND ALL ASSOCIATED EQUIPMENT PER THE POLE SCHEDULE DRAWING 6.04, THE PROJECT
SPECIFICATIONS, AND COR STD. PLANS 117.2 AND 117.3. APPLY DECAL NUMBERING WITH COR POLE ID PER THE POLE CHART AND
COR STD PLAN 121.
O2 EXISTING LUMINAIRE POLE TO REMAIN.
O3 ADJUST EXISTING JUNCTION BOX TO FINISHED GRADE AS NEEDED. EXTEND NEW CONDUIT TO EXISTING JUNCTION BOX.
4 CONSTRUCT SERVICE CABINET FOUNDATION PER COR STD PLAN 126.2. FURNISH AND INSTALL SERVICE CABINET PER COR STD PLAN
122.1. LOCATION AND ORIENTATION OF FOUNDATION AND CABINET SHALL BE VERIFIED BY CITY OF RENTON INSPECTOR PRIOR TO
INSTALLATION OF CONDUITS.
OAPPROXIMATE POWER CONNECTION POINT. CONTRACTOR SHALL PROVIDE CONDUIT TO UTILITY POLE PER THE WIRING SCHEDULE.
CONTRACTOR SHALL COORDINATE WITH PSE FOR SPECIFIC REQUIREMENTS. PSE TO PROVIDE 120/240 VOLT SINGLE PHASE POWER
SOURCE. CONTRACTOR SHALL COORDINATE WITH PSE FOR SERVICE CABINET ELECTRICAL HOOK-UP, SHALL PREPARE/SUBMIT ALL
APPLICABLE PERMITS, AND SHALL PAY ALL ASSOCIATED FEES.
6O SEE DRAWINGS 4.03, 4.05, AND 4.08 FOR CONDUIT AND JUNCTION BOX INSTALLATION DETAILS ON BRIDGE DECK.
O7 RELOCATE EXISTING LUMINAIRE POLE ONTO NEW BRIDGE STRUCTURE PER DRAWING 4.08.
OFURNISH AND INSTALL CITY PEDESTRIAN -SCALE POLE, ARM, LUMINAIRE, AND ALL ASSOCIATED EQUIPMENT PER THE POLE SCHEDULE
DRAWING 6.04, THE PROJECT SPECIFICATIONS, AND COR STD. PLANS 117.2 AND 117.3. APPLY DECAL NUMBERING WITH COR POLE ID
PER THE POLE CHART AND COR STD PLAN 121. MOUNT TO BRIDGE STRUCTURE PER DRAWING 4.08.
O INSTALL 6' DIA. TYPE 3 LOOP DETECTOR PER WSDOT STANDARD PLAN J-50.12.
10 RELOCATE EXISTING WSDOT LUMINAIRE POLE PER THE POLE CHART, DRAWING 6.04. REMOVE EXISTING FOUNDATION AND CONDUIT.
11 RELOCATE EXISTING JUNCTION BOX OUTSIDE SIDEWALK. INTERCEPT AND EXTEND EXISTING CONDUIT.
12 PROTECT AND MAINTAIN EXISTING LOOP DETECTOR.
13 EXTEND CONDUIT TO EXISTING JUNCTION BOX.
14 INSTALL TYPE APS PEDESTRIAN PUSHBUTTON TO EXISTING POLE, REMOVE EXISTING PUSHBUTTON AND REPAIR HOLE PER WSDOT
APPROVED -METHOD. SALVAGED EQUIPMENT BECOMES PROPERTY OF WSDOT.
15 INSTALL NEW FOUNDATION PER WSDOT STANDARD PLAN J-21.10. RELOCATE EXISTING PS POLE, PEDESTRIAN HEAD AND PUSHBUTTON
TO NEW FOUNDATION. REMOVE EXISTING FOUNDATION TO MINIMUM 24" BELOW FINISH GRADE. FILL AND COMPACT VOID.
POLES A AND B
PART OF CITY
LEGEND
EXIST.
NEW/RELOCATED
DESCRIPTION
® z[0
m 0 El
JUNCTION BOX TYPE 1 ,2,8
61
NEMA JUNCTION BOX
-0
VEHICLE SIGNAL HEAD
//-0
PEDESTRIAN SIGNAL HEAD
SIGNAL POLE TYPE III
SIGNAL POLE TYPE II
O
O
TYPE PS POLE
T
NON-APS PPB
>
APS PPB
OLOOP
DETECTION TYPE 3
VIDEO DETECTION ZONE
-----
-----
CONDUIT
H
MAST ARM MOUNTED SIGN
EMERGENCY PRE-EMPTION
DETECTOR
WSDOT ROAD -SCALE POLE
CITY PED.-SCALE POLE
®
CONTROLLER CABINET
®
®
SERVICE CABINET
OCONSTRUCTION
NOTE
OSIGNAL
POLE NUMBER
O
CITY PED.-SCALE POLE
NUMBER
❑
WSDOT ROAD -SCALE POLE
NUMBER
WIRE NOTE
SYSTEM, SVC#1 NSDOT SYSTEM - ILLUMINATION POLE SCHEDULE
C KT A
POLE
STREET
STATION
OFFSET
MOUNT.
ARM
SERVICE/
WATTAGE
LUMINAIRE TYPE -
BASE
POLE / FOUNDATION TYPE
HEIGHT
LENGTH
CIRCUIT
/TYPE
DISTRIBUTION
RELOCATE EX. FOUNDATION PER
❑A
NE PARK DR
54+14.5
56.0' LT
EX
EX
EX
EX
EX
FIXED
WSDOT J-28.30-02 & DRAWING 6.02
RELOCATE EX. FOUNDATION PER
❑B
NE PARK DR
56+33.5
52.0' LT
EX
EX
EX
EX
EX
FIXED
WSDOT J-28.30-02 & DRAWING 6.02
❑C
NE PARK DR
58+41.0
BRIDGE LT
EX
EX
EX
EX
EX
BRIDGE
RELOCATE EX., BRIDGE MOUNT PER
DRAWING 4.08
❑D
NE PARK DR
EX.
EX.
EX
EX
EX
EX
EX
FIXED
EXISTING POLE TO REMAIN
RELOCATE EX. FOUNDATION PER
❑E
NE PARK DR
67+58.0
47.5' LT
EX
EX
EX
EX
EX
FIXED
WSDOT J-28.30-02 & DRAWING 6.02
10 40
0 20 60
SCALE IN FEET
®® ® SURVEYED:
®®�pQNE...j. 000 �� DRAWING NO. 6.04
��G',.oF•yyAs°.,•%, oo DRAWN BY: CITY OF RENTON HIGHLANDS TO LANDING
® c?:'� ti� ••. �� ®oo ..11 PROJECT NO. 31796
DESIGN BY: 19TENWTransportation Engineering Northwest Public Works Department PEDESTRIAN CONNECTION PROJECT CM-1070(007)
g g FED AID NO. CM-1070(007)
0 �;• .�� ® CHECK BY: Transportation Planning I Design I Traffic Impact & Operations TRAFFIC SIGNAL AND ILLUMINATION PLAN
c�•' AFc 56 .� �� ® PO Box 65254, Seattle, WA 98155 Office (206) 361-7333 APPROVED FOR CONSTRUCTION DATE: June 2013
o® �S'' isTE PROJ MGR:
®®o S�ONAL.��®® Project Contact: Chris Bicket, P.E. SHEET NO. 30 OF 44
NUMBER REVISION DESCRIPTION BY APP. DATE °0°°®%%AL ®®®® '��I Proj
Phone:425-250-5002 BY: DATE: