Loading...
HomeMy WebLinkAboutR-3981403 J Q z c� w Q .o 0 i 0 Q U 0 V) E Q X X I N 0 I 0 N 0 E / X X X X I .o a / 9 0 0 v E 0 00 N CO I 0 N 0 a Q a� 0 d O do r- C-KICDAI rr)KICTDI IrTInKI AS PART OF THE DESIGN PROCESS, THE ENGINEER HAS ATTEMPTED TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH OVERHEAD POWER LINES OR SUBSURFACE UTILITIES. HOWEVER, IT IS POSSIBLE FOR THE EXISTING OR PROPOSED CONDITIONS TO CHANGE PRIOR TO IMPLEMENTATION OF THE SCOPE OF WORK IDENTIFIED ON THESE DOCUMENTS. AS THE FIRST ORDER OF BUSINESS. THE CONTRACTOR SHALL POTHOLE EACH NEW LUMINAIRE POLE LOCATION TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH SUBSURFACE UTILITIES. ADDITIONALLY, THE CONTRACTOR SHALL CONFIRM THAT THERE IS A MINIMUM 10-FT CLEARANCE PROVIDED BETWEEN OVERHEAD POWER LINES AND THE PROPOSED LUMINAIRE POLES PRIOR TO POLE PLACEMENT. ADDITIONAL CLEARANCE MAY BE REQUIRED AS DIRECTED BY THE UTILITY. THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY IF A CONFLICT IS DISCOVERED. CITY SYSTEM - ILLUMINATION POLE SCHEDULE POLE STREET STATION OFFSET MOUNT. ARM SERVICE/ WATTAGE LUMINAIRE AND ARM BASE POLE / FOUNDATION TYPE COR ID HEIGHT LENGTH CIRCUIT /TYPE TYPE O1 NE PARK DR 53+73.5 62.5' LT 14' 4' SERVICE #1 60W30LED LUMEC PER PROJECT FIXED HAPCO PER PROJECT SPECS, ILLUM A SPECS FDN PER DRAWING 6.02 O2 NE PARK DR 54+45.5 56.0' LT 14' 4' SERVICE #1 60W30LED LUMEC PER PROJECT FIXED HAPCO PER PROJECT SPECS, ILLUM A SPECS FDN PER DRAWING 6.02 O3 NE PARK DR 55+20.5 55.0' LT 14' 4' SERVICE #1 60W30LED LUMEC PER PROJECT FIXED HAPCO PER PROJECT SPECS, ILLUM A SPECS FDN PER DRAWING 6.02 O4 NE PARK DR 55+96.0 53.0' LT 14' 4' SERVICE #1 60W30LED LUMEC PER PROJECT FIXED HAPCO PER PROJECT SPECS, ILLUM A SPECS FDN PER DRAWING 6.02 NE PARK DR 56+72.5 50.5 LT 14' 4' SERVICE #1 60W30LED LUMEC PER PROJECT FIXED HAPCO PER PROJECT SPECS, ILLUM A SPECS FDN PER DRAWING 6.02 O6 NE PARK DR 57+40.5 41.5 LT 14' 4' SERVICE #1 60W30LED LUMEC PER PROJECT FIXED HAPCO PER PROJECT SPECS, ILLUM A SPECS FDN PER DRAWING 6.02 O7 NE PARK DR 58+11.5 BRIDGE LT 14' 4 SERVICE #1 60W30LED LUMEC PER PROJECT FIXED HAPCO PER PROJECT SPECS, ILLUM A SPECS FDN PER DRAWING 6.02 O NE PARK DR 58+83.5 BRIDGE LT 14' 4' SERVICE #1 60W30LED LUMEC PER PROJECT FIXED HAPCO PER PROJECT SPECS, ILLUM A SPECS FDN PER DRAWING 6.02 O9 NE PARK DR 59+54.5 BRIDGE LT 14' 4' SERVICE #1 60W30LED LUMEC PER PROJECT FIXED HAPCO PER PROJECT SPECS, ILLUM A SPECS FDN PER DRAWING 6.02 10 NE PARK DR 60+22.5 50.0' LT 14' 4' SERVICE #1 60W30LED LUMEC PER PROJECT FIXED HAPCO PER PROJECT SPECS, ILLUM A SPECS FDN PER DRAWING 6.02 11 NE PARK DR 60+98.5 56.0' LT 14' 4' SERVICE #1 60W30LED LUMEC PER PROJECT FIXED HAPCO PER PROJECT SPECS, ILLUM A SPECS FDN PER DRAWING 6.02 12 NE PARK DR 61 +77.5 61 LT 14' 4' SERVICE #1 60W30LED LUMEC PER PROJECT FIXED HAPCO PER PROJECT SPECS, .5' ILLUM A SPECS FDN PER DRAWING 6.02 13 NE PARK DR 62+31.5 66.5' LT 14' 4' SERVICE #1 60W30LED LUMEC PER PROJECT FIXED HAPCO PER PROJECT SPECS, ILLUM A SPECS FDN PER DRAWING 6.02 14 NE PARK DR 62+96.5 77.0' LT 14' 4' SERVICE #1 60W30LED LUMEC PER PROJECT FIXED HAPCO PER PROJECT SPECS, ILLUM A SPECS FDN PER DRAWING 6.02 15 NE PARK DR 64+25.5 58.0' LT 14' 4' SERVICE #2 60W30LED LUMEC PER PROJECT FIXED HAPCO PER PROJECT SPECS, ILLUM A SPECS FDN PER DRAWING 6.02 16 NE PARK DR 64+74.0 50.5' LT 8' 4' SERVICE #2 60W30LED LUMEC PER PROJECT FIXED HAPCO PER PROJECT SPECS, ILLUM A SPECS JERSEY -BARRIER MOUNTED 17 NE PARK DR 65+45.0 50.5' LT 8' 4' SERVICE #2 60W30LED LUMEC PER PROJECT FIXED HAPCO PER PROJECT SPECS, ILLUM A SPECS JERSEY -BARRIER MOUNTED 18 NE PARK DR 66+02.0 50.5' LT 8' 4' SERVICE #2 60W30LED LUMEC PER PROJECT FIXED HAPCO PER PROJECT SPECS, ILLUM A SPECS JERSEY -BARRIER MOUNTED 19 NE PARK DR 66+87.5 59.5' LT 14' 4' SERVICE #2 60W30LED LUMEC PER PROJECT FIXED HAPCO PER PROJECT SPECS, ILLUM A SPECS FDN PER DRAWING 6.02 20 NE PARK DR 67+78.5 59.5' LT 14' 4' SERVICE #2 60W30LED LUMEC PER PROJECT FIXED HAPCO PER PROJECT SPECS, ILLUM A SPECS FDN PER DRAWING 6.02 21 NE PARK DR 68+70.5 59.5' LT 14' 4' SERVICE #2 60W30LED LUMEC PER PROJECT FIXED HAPCO PER PROJECT SPECS, ILLUM A SPECS FDN PER DRAWING 6.02 22 NE PARK DR 69+45.0 60.0' LT 14' 47 SERVICE #2 60W30LED LUMEC PER PROJECT -F-FIXED HAPCO PER PROJECT SPECS, ILLUM A SPECS FDN PER DRAWING 6.02 SERVICE #2 88 CONSTRUCTION NOTES ILLUMINATION WIRING DIAGRAM (SERVICE #2) NEW JUNCTION BOX (TYP.) ILLUM A NE PARK DR 2-#8 ILLUM A ILLUM B SPARE ILLUM C SPARE 15 16 17 18 19 20 21 22 NEW LUMINAIRE (TYP.) CITY SYSTEM - BREAKER SCHEDULE (SERVICE #2) CIRCUIT BREAKER CONTACTOR ILLUM A 2P-20 AMP 30 AMP ILLUM B (SPARE) 2P-20 AMP 30 AMP ILLUM C (SPARE) 2P-20 AMP 30 AMP ILLUMINATION WIRING SCHEDULE RACEWAY CONDUIT SIZE ILLUM. #8 EQUIP. GRND. #8 SVC PWR #2 2C(SH) LOOP PULL WIRE CONDUIT FILL ALLOW. FILL (26% ALLOW. FILL (40%) NO. EX. NEW EX. NEW EX. NEW EX. NEW EX. NEW 1 2" NEW SCH 40 CITY 2 1 0.17 0.86 --- 2 2" NEW RGS CITY 2 1 0.17 0.89 --- 3 3" NEW RGS CITY 3 0.94 1.95 --- 4 2" NEW SCH 40 WSDOT 2 1 0.17 0.86 --- 5 2" EX WSDOT 2 1 0.17 0.86 - - - 6 2" NEW RGS WSDOT 2 0.17 0.86 - - - 7 2" NEW SCH 40 WSDOT 3 0.27 0.86 - - - 8 4" NEW SCH 40 SPARE ITS 1 - - - 3.35 - - - 9 4" NEW RGS SPARE ITS 1 - - - 3.35 --- 1 CONSTRUCT CITY PEDESTRIAN -SCALE LUMINAIRE POLE FOUNDATION PER COR STD PLAN 117.2. FURNISH AND INSTALL CITY PEDESTRIAN -SCALE POLE, ARM, LUMINAIRE, AND ALL ASSOCIATED EQUIPMENT PER THE POLE SCHEDULE DRAWING 6.04, THE PROJECT SPECIFICATIONS, AND COR STD. PLANS 117.2 AND 117.3. APPLY DECAL NUMBERING WITH COR POLE ID PER THE POLE CHART AND COR STD PLAN 121. O2 EXISTING LUMINAIRE POLE TO REMAIN. O3 ADJUST EXISTING JUNCTION BOX TO FINISHED GRADE AS NEEDED. EXTEND NEW CONDUIT TO EXISTING JUNCTION BOX. 4 CONSTRUCT SERVICE CABINET FOUNDATION PER COR STD PLAN 126.2. FURNISH AND INSTALL SERVICE CABINET PER COR STD PLAN 122.1. LOCATION AND ORIENTATION OF FOUNDATION AND CABINET SHALL BE VERIFIED BY CITY OF RENTON INSPECTOR PRIOR TO INSTALLATION OF CONDUITS. OAPPROXIMATE POWER CONNECTION POINT. CONTRACTOR SHALL PROVIDE CONDUIT TO UTILITY POLE PER THE WIRING SCHEDULE. CONTRACTOR SHALL COORDINATE WITH PSE FOR SPECIFIC REQUIREMENTS. PSE TO PROVIDE 120/240 VOLT SINGLE PHASE POWER SOURCE. CONTRACTOR SHALL COORDINATE WITH PSE FOR SERVICE CABINET ELECTRICAL HOOK-UP, SHALL PREPARE/SUBMIT ALL APPLICABLE PERMITS, AND SHALL PAY ALL ASSOCIATED FEES. 6O SEE DRAWINGS 4.03, 4.05, AND 4.08 FOR CONDUIT AND JUNCTION BOX INSTALLATION DETAILS ON BRIDGE DECK. O7 RELOCATE EXISTING LUMINAIRE POLE ONTO NEW BRIDGE STRUCTURE PER DRAWING 4.08. OFURNISH AND INSTALL CITY PEDESTRIAN -SCALE POLE, ARM, LUMINAIRE, AND ALL ASSOCIATED EQUIPMENT PER THE POLE SCHEDULE DRAWING 6.04, THE PROJECT SPECIFICATIONS, AND COR STD. PLANS 117.2 AND 117.3. APPLY DECAL NUMBERING WITH COR POLE ID PER THE POLE CHART AND COR STD PLAN 121. MOUNT TO BRIDGE STRUCTURE PER DRAWING 4.08. O INSTALL 6' DIA. TYPE 3 LOOP DETECTOR PER WSDOT STANDARD PLAN J-50.12. 10 RELOCATE EXISTING WSDOT LUMINAIRE POLE PER THE POLE CHART, DRAWING 6.04. REMOVE EXISTING FOUNDATION AND CONDUIT. 11 RELOCATE EXISTING JUNCTION BOX OUTSIDE SIDEWALK. INTERCEPT AND EXTEND EXISTING CONDUIT. 12 PROTECT AND MAINTAIN EXISTING LOOP DETECTOR. 13 EXTEND CONDUIT TO EXISTING JUNCTION BOX. 14 INSTALL TYPE APS PEDESTRIAN PUSHBUTTON TO EXISTING POLE, REMOVE EXISTING PUSHBUTTON AND REPAIR HOLE PER WSDOT APPROVED -METHOD. SALVAGED EQUIPMENT BECOMES PROPERTY OF WSDOT. 15 INSTALL NEW FOUNDATION PER WSDOT STANDARD PLAN J-21.10. RELOCATE EXISTING PS POLE, PEDESTRIAN HEAD AND PUSHBUTTON TO NEW FOUNDATION. REMOVE EXISTING FOUNDATION TO MINIMUM 24" BELOW FINISH GRADE. FILL AND COMPACT VOID. POLES A AND B PART OF CITY LEGEND EXIST. NEW/RELOCATED DESCRIPTION ® z[0 m 0 El JUNCTION BOX TYPE 1 ,2,8 61 NEMA JUNCTION BOX -0 VEHICLE SIGNAL HEAD //-0 PEDESTRIAN SIGNAL HEAD SIGNAL POLE TYPE III SIGNAL POLE TYPE II O O TYPE PS POLE T NON-APS PPB ­> APS PPB OLOOP DETECTION TYPE 3 VIDEO DETECTION ZONE ----- ----- CONDUIT H MAST ARM MOUNTED SIGN EMERGENCY PRE-EMPTION DETECTOR WSDOT ROAD -SCALE POLE CITY PED.-SCALE POLE ® CONTROLLER CABINET ® ® SERVICE CABINET OCONSTRUCTION NOTE OSIGNAL POLE NUMBER O CITY PED.-SCALE POLE NUMBER ❑ WSDOT ROAD -SCALE POLE NUMBER WIRE NOTE SYSTEM, SVC#1 NSDOT SYSTEM - ILLUMINATION POLE SCHEDULE C KT A POLE STREET STATION OFFSET MOUNT. ARM SERVICE/ WATTAGE LUMINAIRE TYPE - BASE POLE / FOUNDATION TYPE HEIGHT LENGTH CIRCUIT /TYPE DISTRIBUTION RELOCATE EX. FOUNDATION PER ❑A NE PARK DR 54+14.5 56.0' LT EX EX EX EX EX FIXED WSDOT J-28.30-02 & DRAWING 6.02 RELOCATE EX. FOUNDATION PER ❑B NE PARK DR 56+33.5 52.0' LT EX EX EX EX EX FIXED WSDOT J-28.30-02 & DRAWING 6.02 ❑C NE PARK DR 58+41.0 BRIDGE LT EX EX EX EX EX BRIDGE RELOCATE EX., BRIDGE MOUNT PER DRAWING 4.08 ❑D NE PARK DR EX. EX. EX EX EX EX EX FIXED EXISTING POLE TO REMAIN RELOCATE EX. FOUNDATION PER ❑E NE PARK DR 67+58.0 47.5' LT EX EX EX EX EX FIXED WSDOT J-28.30-02 & DRAWING 6.02 10 40 0 20 60 SCALE IN FEET ®® ® SURVEYED: ®®�pQNE...j. 000 �� DRAWING NO. 6.04 ��G',.oF•yyAs°.,•%, oo DRAWN BY: CITY OF RENTON HIGHLANDS TO LANDING ® c?:'� ti� ••. �� ®oo ..11 PROJECT NO. 31796 DESIGN BY: 19TENWTransportation Engineering Northwest Public Works Department PEDESTRIAN CONNECTION PROJECT CM-1070(007) g g FED AID NO. CM-1070(007) 0 �;• .�� ® CHECK BY: Transportation Planning I Design I Traffic Impact & Operations TRAFFIC SIGNAL AND ILLUMINATION PLAN c�•' AFc 56 .� �� ® PO Box 65254, Seattle, WA 98155 Office (206) 361-7333 APPROVED FOR CONSTRUCTION DATE: June 2013 o® �S'' isTE PROJ MGR: ®®o S�ONAL.��®® Project Contact: Chris Bicket, P.E. SHEET NO. 30 OF 44 NUMBER REVISION DESCRIPTION BY APP. DATE °0°°®%%AL ®®®® '��I Proj Phone:425-250-5002 BY: DATE: