HomeMy WebLinkAboutR-398145I! 111
CL
to
- - 13.8 B-4
3/4"
d year` - 31A.v
16.94 B-3 Ei-,
2 GPM 1" a1+00
W10 A
,2+00
NE PARK DRIVE
/
II
NOTE:
THE CONTRACTOR SHALL FIELD VERIFY THE LOCATION
OF THE EXISTING 8-INCH WATER LINE AND SHALL
EXCAVATE FOR THE TRENCHING OF THE NEW SERVICE
LINE AND FOR THE METER THAT WILL BE INSTALLED
BY THE CITY. CONTRACTOR SHALL RESTORE THE
TRENCH AREA ONCE THE METER IS INSTALLED.
5
y i
4
B-6
10.92
f
1"
GPM
k1w
REVISION DESCRIPTION
N
13.52
se+0o _
—1 N PARK DRIVE
61-0
1v.
r/
i�
I�
14
it
3/4"
S�tGve 1�
6.24 C
GPM
+ .
i'
' I
I
v '
t•
r
LOCATE VALVES 5' MIN. FROM DRIVEWAY APRON
._4 G , cJ
15.0
GPM
— 59+00
t 70+W
SURVEYED: JFS
Km STATE OF 8 CITY OF RENTON
DRAWN BY: MGS - �- WASHINGTON
REGISTERED
DESIGN BY: MGS LAND RCH,TEf,T Public Works Department
CHECK BY: LBM I®rs r.m a Q ..y „� dj'.201�
APP FOR CONSTRUCTION
PROD MGR: LBM CERTIFICATE TE TIS INOR 414 BY / DATE �
BY APP. DATE ...
P.V.C. PIPE SCHEDULE
`.
PIPES ARE TO BE SIZED ACCORDING TO
G.P.M (GALLONS PER MINUTE) DEMAND
DOWN LINE FLOW VELOCITIES ARE NOT TO
EXCEED 5' PER SECOND.
SCHEDULE 40 P.V.C. MAINLINE PIPE
i
G.P.M. PIPE SIZE
0 - 8 3/4"
9-
12 - 22 1 1/4"
i'
23 - 35 1 1/2"
36 - 50 2"
CLASS 200 P.V.C. LATERAL LINES
3►
G.P.M. PIPE SIZE
O
0 - 10 3/4"
O
10 — 14 1"
14 — 24 1 1/4"
((�
24 — 30 1 1/2"
30 — 50 2"
CONTROL VALVE FLAG
J
G.P.M.
T
e.
V-1
CONTROLLER DESIGNATION
G.P.M.
1"
AND VALVE NUMBER
�V
VALVE SIZE
IRRIGATION LEGEND
SYMBOL
DESCRIPTION 1
SPRAY HEADS:
6' POP-UP HEADS (DESIGN PRESSURE 30 P.S.I.) 1
RAIN BIRD 1806-SAM SPRAY BODY / 8 SERIES MPR
II
8' SERIES -HALF (0.47 GPM MPR NOZZLE)
0
4'X15' LEFT CENTER STRIP (0.49 GPM MPR NOZZLE)
C3
4'X15' RIGHT CENTER STRIP (0.49 GPM MPR NOZZLE)
13
4'X30' SIDE STRIP (1.21 GPM ROTARY NOZZLE)
ROTARY HEADS:
6 POP-UP HEADS DESIGN PRESSURE 30 P.S.I.
RAIN BIRD 1806-SAM SPRAY BODY /
13'-18' SERIES (0.80 GPM ROTARY NOZZLE)
K
Q-QUARTER, H-HALF, TT -THREE QUARTER
EQUIPMENT:
IRRIGATION POINT OF CONNECTION (120 P.S.I.):
O
3/4' WATER METER (2-TOTAL IN METER BOX)
®
BACKFLOW PREVENTION: DOUBLE CHECK VALVE ASSEMBLY
(FEBCO 1/2- 85OU IN GROUND VAULT)
PEDESTAL MOUNT CONTROLLER (STAINLESS STEEL)
TORO SENTINAI_ (2-TOTAL)
®
MASTER VALVE / FLOW METER (IN VALVE BOX)
TORO 220 1' BRASS VAIAVE /70RO 075 TFS FLOW SENSOR
ELECTRONIC CONTROL VALVE (IN VALVE BOX)
RAIN BIRD 100-PEB
QUICK COUPLER ASSEMBLY (IN VALVE BOX)
RAIN BIRD 44-LRC
®
BRASS BALL VALVE (IN VALVE BOX)
NIBCO 1-1/2' T-580-A
®
SLEEVES: SCHED. 40 PVC; 2X LINE SIZE
LATERAL LINES: CLASS 200 PVC, (MIN. 14" COVER)
MAINLINE: SCHED. 40 PVC, (MIN. 24" COVER)
SERVICE LINE
—
UNCONNECTED PIPE
CONSTRUCTION NOTES
tO POINT OF CONNECTION: 1' METER (2 OF 2) AT EXTENSION OF EXISTING OF 8' WATER MAIN.
OLOCATE IRRIGATION MAINLINE 6' FROM EDGE OF SIDEWALK IN PLANTING AREA
OLOCATE IRRIGATION MAIN 6' FROM EDGE OF ACCESS ROAD.
(D 120V POWER SERVICE TO CONTROLLER
2D' 0'
20'
m-
SCALE
IN FEET
8.02
HIGHLANDS TO LANDING
DRAWINGNo.
PEDESTRIAN CONNECTION PROJECT CM-1070(007)
PROJECT NO. 31796
FEDAIDNO. CM-10701007)
IRRIGATION PLAN
DATE: June.2013
SHEET NO. 34 OF 44