Loading...
HomeMy WebLinkAboutR-398147FINISHED GRADE NATIVE BACKFILL 0 00 E 0. z 0 J 04 w 0 L U ,i 1 " CLEAR THERMOPLASTIC, LOCKING RUBBER COVER LABELED WITH "DO NOT DRINK" STAINLESS STEEL HOSE CLAMP (2 REQUIRED) GRAVEL BACKFILL FOR DRAINAGE 6" MIN. LAYER FACTORY PRE —ASSEMBLED PVC TRIPLE SWING ASSEMBLY #4 REBAR (30" MIN.) NOT TO SCALE GROUND WIRE CONDUIT, MIN. 1 1 /2". GROUND PER ASIC GUIDELINES 2" CONDUIT FOR CONTROL WIRES (UP TO 24 STATIONS) 3/4" POWER CONDUIT FOR 120 VOLT SERVICE: SIZE, TYPE, DEPTH PER LOCAL CODE A -_ 4 d FRONT SECTION/ELEVATION 1" CLEAR, TYP. QUICK COUPLER VALVE TWO PIECE BODY L�—; . . i • DIA. X : DEEP BLICK NI Z PVC SCH. 80 THREADED RISER PVC SCH 40 TEE PVC MAINLINE N TORO SENTINEL TOP ENTRY FIELD SATELLITE CONTROLLER STAINLESS STEEL PEDESTAL 2" CONDUIT FOR CONTROL WIRES (25-48 STATIONS) 0to] wa[on 01M_111 PEDESTAL BASE: CONCRETE OR PREFABRICATED FINISH GRADE 1 /2" CONDUIT FOR SENSOR WIRES NOTES: 1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS. I an w 11 � UMM NOT TO SCALE POP-UP HEAD NOT TO SCALE FINISH GRADE/TOP OF MULCH POP—UP SPRAY OR ROTOR HEAD PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) FACTORY PRE —ASSEMBLED PVC TRIPLE SWING ASSEMBLY PVC LATERAL PIPE PVC SCH 40 TEE OR ELL #3 REBAR STAKE TO MARK SLEEVE (PAINT TOP SAFETY ORANGE) PAVEMENT o/",7 <BACKFILL AS SPECIFIED --i j ...... CONTROL WIRE `'' w ' '— �' ' SCHED. 40 P.V.C. SLEEVE 2X LINE SIZE `II I I I NOTES: o EXTEND IRRIGATION SLEEVE 6 o BEYOND EACH SIDE OF PAVING. MAINLINE OR o DEPTH OF MAINLINE = 24". LATERAL PIPE o DEPTH OF LATERAL @ PAVING = 14" MIN. DEPTH OF LINES UNDER DRIVING SURFACES = 24" MIN. SLEEVE UNDER 1-405 SIB OFF RAMP SHALL BE INSTALLED BY BORING METHOD IRRIGATION SLEEVE NOT TO SCALE NOTES: " SNAKE ALL P.V.C. PIPING IN TRENCHING. TIE LOOSE 3' LOOP IN ALL IRRIGATION WIRING AT CHANGES IN DIRECTION GREATER THAN 30 DEG.. UNTIE AFTER ALL CONNECTIONS HAVE BEEN MADE. NOT TO SCALE COPPER TRECE WIRE (FROM VALVE TO END OF ZONE) LATERAL LINE MAINLINE IRRIGATION WIRING WHERE ELECTRICAL WIRING DOES NOT SHARE COMMON TRENCH, OVEREXCAVATE TRENCH 2" MIN. AND BACKFILL WITH SPECIFIED BEDDING MATERIAL. LOCATE ALL WIRING NOT IN COMMON TRENCHES ACCURATELY ON RECORD DWGS.. SURVEYED: JFS Q DRAWN BY: ACB • , STATE OF - CITY OF RENTON HIGHLANDS TO LANDING DRAWING NO. H.O4 WASHINGTON � PROJECT NO. 31796 DESIGN BY: ACB REGISTERED — Public Works Department PEDESTRIAN CONNECTION PROJECT CM-1070 007 LANDS AP CHITECiT P FED AID NO. CM-1070(007) CHECK BY: LBM HanmiGlobal Partner � 10230 NE Points DriveAPPROVBO FOR CONSTRUCTION PROD MGR: LBM suite 400 IRRIGATION DETAILS DATE: June.2013 Kirkland lfas6ingtoa 98033 C U R T I S L AP I E R R E Phone: (425) 822-4446 CERTIFICATE NO. 474 BY: DATE: /� SHEET NO. 36 OF 44 NUMBER REVISION DESCRIPTION BY APP. DATE FAX: (425) 827-9577 / l% www.otak.com /