Loading...
HomeMy WebLinkAboutR-394626n 0 N N on w 0 0 Do O i O i 0 z w 0 n 0 0 0 00 0 i z 0 z w i w 0 i IRRIGATION SCHEDULE SYMBOL MANUFACTURER MODEL NO. DESCRIPTION ® ® RAINBIRD 1806-6 VAN SERIES SHRUB HEAD — 6" PLASTIC POP—UP. ADJ ARC NOZ, 4'-6' RADIUS AT 30 PSI. INSTALL ON SWING JOINT, SEE DETAIL THIS SHEET 8Q 8H A 44 EST SST RAINBIRD 1806-15 STRIP SERIES SHRUB HEAD — 6" PLASTIC POP—UP. 5'x15', 5'x3O' AT 30 PSI. SIDE & END STRIP NOZZLE, INSTALL ON SWING JOINT, SEE DETAIL THIS SHEET 2 RAINBIRD 1806-15 END STRIP SHRUB HEAD — 6" PLASTIC POP—UP. 3'X12' AT 30 PSI. END STRIP NOZZLE, INSTALL ON SWING JOINT, SEE DETAIL THIS SHEET W PCS-030 8Q 8H RAINBIRD 1806-8 VAN SERIES SHRUB HEAD — 6" PLASTIC POP—UP. ADJ ARC NOZ, 6'-8' RADIUS AT 30 PSI. INSTALL ON SWING JOINT, SEE DETAIL THIS SHEET SENTINEL (1) 9—STATION OUTDOOR CONTROLLER TO BE PROVIDED TO THE CONTRACTOR BY THE CITY OF RENTON. PROVIDE 3 © TORO SATELLITE SPARE WIRES (RED) FROM CONTROLLER THROUGH EACH CONTROL VALVE BOX, TO FURTHEST VALVE BOX FROM SCN09WS3U CONTROLLER. RAINBIRD PEB AUTOMATIC CONTROL VALVE — SIZE AS NOTED ON PLAN. POC EXISTING POINT OF CONNECTION EXISTING IRRIGATION METER — — PVC SCH 40, IRRIGATION MAIN LINE - 24" MIN COVER PVC SCH 40, LATERAL SUPPLY LINE- 18" MIN. COVER - SIZE AS NOTED. — — — — — SLEEVING, PVC SCHEDULE 40, SIZE TWICE INSERT PIPE DIA. 1 INDICATES VALVE# 10.5 INDICATES APPROX. GPM 1" INDICATES VALVE SIZE SUPPLY (1) DRIP BUBBLER ON SPIKE PER FLOWER BASKET (TWO BASKETS PER LUMINAIRE). FLOW RATE BASED ON APPROX 4GPH A aD FLOWER BASKET DRIP EQUIPMENT 15-30PS1. SUPPLY TUBING FROM PAVEMENT PR PLANTER VALVE BOX CONNECTION (SEE DETAIL, THIS SHEET AND SHEET 33A) TO LUMINAIRE POLE AND UP TO ACCESS HOLE PROVIDED FOR MICROTUBING AT FLOWER BASKETS. SPLIT SUPPLY LINE OUTSIDE POLE WITH 1 /4" BARBED TEE TO SUPPLY MICROTUBING TO EACH HANGING BASKET ARM. COIL 3' EXCESS (MIN.) MICROTUBING IN EACH BASKET LOCATION. TIE MICROTUBING TO LUMINAIRE ARMS NEATLY WITH BLACK WIRE TIE OR OTHER APPROVED TIE. SUPPLY CITY OF RENTON WITH REQUIRED NUMBER OF DRIP EMITTERS AND SPIKES FOR FUTURE BASKET INSTALLATION. SEE ADDITIONAL NOTES THIS SHEET. AD 3/4" DRIP CONTROL VALVE ASSEMBLY EACH DRIP ZONE TO INCLUDE (SEE DRIP CONTROL VALVE DETAIL, THIS SHEET): 1. DRIP CONTROL (LOW FLOW) VALVE 2. 3/4" PRESSURE REGULATING FILTER 3. PVC BALL VALVE ® DRIP ACCESS VALVE BOX SEE INSTALLATION DETAIL IN PAVEMENT OR PLANTER THIS SHEET AND SHEET 33A. SEE ILLUMINATION DETAILS SHEET 26 AUTOMATIC CONTROL VALVE N TS VALVE BOX FLUSH IN LAWN AREAS, 1/2" ABOVE FINISH GRADE IN SHRUB AND GROUNDCOVER AREAS. AUTOMATIC CONTROL VALVE SCHEDULE 80 REDUCER (SxTH) SCHEDULE 80 UNION - TYP. PVC LATERAL LINE 4" MIN. PEA GRAVEL BRICK SUPPORTS; TYP. EACH CORNER PVC 90° ELBOW PVC PIPE - THREADED SCH 80 NIPPLE LENGTH AS REQ. PVC PRESSURE MAIN PVC THREADED ELBOW OR TEE FINISH GRADE—, III N N FINISH SURFACE OF PAVEMENT GENERAL NOTES OR CURB SPRINKLER FLUSH WITH GRADE ;mll 1. COORDINATE INSTALLATION OF IRRIGATION SYSTEM WITH INSTALLATION FINISH GRADE OF OTHER UTILITIES. LOCATE AND PROTECT ALL UNDERGROUND /I/ivllll �\lhflvllffilll UTILITIES DURING INSTALLATION OF IRRIGATION SYSTEM. ° - III —III= III 2. IRRIGATION SYSTEM SHALL BE INSTALLED, TESTED, MAINTAINED AND III —III GUARANTEED AS PER SPECIFICATIONS. III —III 3. IRRIGATION SYSTEM IS DESIGNED TO OPERATE FROM 30 PSI. CONTRACTOR SHALL FIELD CHECK EXISTING WATER PRESSURE a° = ADJUSTING PRV AS NECESSARY TO PROVIDE OPTIMUM PERFORMANCE 3" MIN NOZZLE AND BODY PER 4. LOCATIONS OF IRRIGATION MAIN LINE, LATERALS, SLEEVING AND SPECIFICATIONS. USE VALVES INDICATED ON DRAWINGS ARE SCHEMATIC ONLY. ADJUST 6" MAX III— BOTTOM INLET ONLY LOCATIONS AS NECESSARY. DO NOT OVERSPRAY ONTO PAVED SURFACES. TWO (2) MARLEX STREET ELLS 5. IRRIGATION MAIN LINE LOCATION IS DIAGRAMMATIC, LINE SHALL BE PLACED IN PLANTING AREAS WHERE EVER POSSIBLE. SCHEDULE 80 PVC NIPPLE, 6" MINIMUM LENGTH 6. MAIN LINE SHALL BE BURIED TO A DEPTH OF 24" BELOW FINISH z GRADE. LATERAL LINE FOR SPRAY ZONES SHALL BE BURIED TO A — MARLEX STREET ELL DEPTH OF 18" BELOW FINISH GRADE. N 7. SLEEVE UNDER ALL PAVED SURFACES, CONCRETE SIDEWALK. SEE IRRIGATION PLANS FOR LOCATION OF PVC SLEEVING, SLEEVING SHALL BE 2 TIMES THE DIAMETER OF THE INSERT PIPE AND WIRES. SCHEDULE 40 PVC FITTINGS, TYP. LATERAL, TYP. NOTE: USE TEFLON TAPE AT ALL THREADED FITTINGS TYPICAL SWING JOINT NOTE: N I b INSTALL WIRE BUNDLE BELOW PIPE COPPER TRACE WIRE NYLON TY-WRAP AT 10' OC IRRIGATION MAINLINE, SIZE AS INDICATED ON PLAN WIRE BUNDLE CONTROL WIRE BUNDLE INSTALLATION N TS PVC BALL VALVE, THREADED ENDS, SIZE TO MATCH PIPE WATERPROOF CONNECTION VALVE BOX 30" LINEAR LENGTH OF WIRE, COILED DRIP CONTROL (LOW FLOW) VALVE PRESSURE REGULATING FILTER SCHEDULE 80 REDUCER (SxTH) SCHEDULE 80 UNION, TYP. PVC LATERAL LINE 77 o 01. ------ 4" MIN. PEA GRAVEL O o?" ---- BRICK SUPPORTS, TYP. EACH CORNER 0 DRIP CONTROL VALVE N TS PVC 90° ELBOW SCHEDULE 40 PVC PIPE, NIPPLE LENGTH AS REQUIRED PVC PRESSURE MAIN WITH TRACER WIRE PVC ELBOW OR TEE 1 /2" FEMALE ADAPTER FOR 1 /4" MICROTUBING 1 /2" PVC NIPPLE 1 /2" PVC RISER BRICK SUPPORTS, TYP. EACH CORNER PVC LATERAL SUPPLY LINE, SIZE AS NEEDED PVC SLEEVE IN PAVED AREAS 8• CONTROLLER WIRES SHALL BE TAPED TOGETHER IN A BUNDLE AT 10' INTERVALS. SNAKE WIRE IN BOTTOM OF PIPE TRENCH WHERE POSSIBLE. WHERE PIPE TRENCH IS UNAVAILABLE WIRES SHALL BE PLACED IN SLEEVING. WIRES TO CONTROLLER SHALL BE PLACED IN 1" / 1.5" SLEEVE, USE 3M DBY SPLICE KITS. 9. ALL EQUIPMENT SHALL BE AS SPECIFIED OR APPROVED EQUAL BY CITY OF RENTON. SYSTEM IS SPECIFICALLY DESIGNED FOR IRRIGATION EQUIPMENT SHOWN ON PLANS AND SUBSTITUTION WILL REQUIRE REDESIGN AND RECALCULATION OF IRRIGATION ZONES, BY THE CONTRACTOR 10. NO GALVANIZED FITTINGS. ONLY BRASS OR SCH 40 PVC SHALL BE USED. 11. IRRIGATION TRENCHING NEAR ANY TREES TO REMAIN SHALL BE DONE WITH THE MINIMUM AMOUNT OF DISTURBANCE POSSIBLE. TRIM AND CUT CLEAN ANY EXPOSED OR DAMAGED ROOTS. 12. MICROTUBING FOR FLOWER BASKETS SHALL BE BLACK, UV RESISTANT 13. DRIP ACCESS VALVE BOXES FOR PAVEMENT SHALL H2 PRECAST JUNCTION BOX TYPE 1, AS APPROVED BY ENGINEER. ACCESS BOXES INSTALLED IN PLANTERS SHALL (12"X10") CARSON VALVE BOX 1012 PAVEMENT RATED VALVE BOX, SEE GENERAL NOTES THIS SHEET FINISH GRADE SIDEWALK CEMENT zi CONCRETE SIDEWALK 1 /4" MICROTUBING TO PEDESTRIAN LUMINAIRE POLE S x T ADAPTER, SIZE AS NEEDEDv\%/j ,�//��//��//�� 1" CONDUIT SWEEP TO (TEE WHERE APPLICABLE FOR ; �///�/ LUMINAIRE BASE, SEE SUPPLY TO NEXT LUMINAIRE) \�j�\�j�\�j�\�j�\�j�\�j,��� ILLUMINATION DETAIL SHEET 26 PVC TEE OR ELBOW COMPACTED SUBGRADE 0 DRIP ACCESS VALVE BOX IN PAVEMENT FOR CONNECTION TO LUMINAIRE POLE N TS