Loading...
HomeMy WebLinkAboutT-3977016 3 0 U i r in w Q z w U_ AV—r Aa IrrT r A rAft !1 THIS DRAWING HAS BEEN REVISED TO REFLECT INFORMATION PROVIDED BY THE CONSTRUCTION CONTRACTOR, OBSERVING ENGINEER, AND PROJECT ENGINEER DEFINING KNOWN DIFFERENCES BETWEEN THE FACILITIES SHOWN ON THE ORIGINAL CONSTRUCTION DOCUMENTS TO THOSE CONSTRUCTED. THE INFORMATION PROVIDED ON THESE RECORDS, HAS BEEN ASSUMED TO BE CORRECT AND HAS NOT BEEN VERIFIED BY THE ENGINEER, WHO IS UNDER NO OBLIGATION OR DUTY TO VERIFY SUCH ACCURACY AND/OR COMPLETENESS. SAID ENGINEER, BY PLACING HER/HIS PROFESSIONAL SEAL ON THIS DRAWING, HAS REVIEWED THE REVISION(S) TO VERIFY THAT THE CHANGES AS DEFINED BY THESE RECORDS DO NOT APPEAR TO BE ADVERSE TO THE PLANNED USE AND/OR INTENT OF THE ORIGINAL DESIGN. THERE IS NO WARRANTY HEREIN FOR THE ACCURACY OF THE CHANGES SHOWN, NOR ASSURANCE THAT ALL DIFFERENCES TO THE ORIGINAL DRAWING HAVE BEEN IDENTIFIED. PROPOSED SIGNAL AND ILLUMINATION / SERVICE CALL 48 HOURS BEFORE YOU DIG 1-800-424-5555 MATCH LINE STA 104+50 SEE SHEET E2 TIB # 8-1-102(033)-1 1019 39TH AVENUE SE, SUITE 100 PUYALLUP, WASHINGTON 98374 T.253.604.6600 F.253.604.6799 www.parametdx.com VOISM110111 r SIGNAL AND INTERCONNECT NOTES: El CONSTRUCT TYPE 3 ADVANCE LOOP(S) PER WSDOT STD. PLAN J-50.12-00 .. . . - r NPj • r • • • r • O RELOCATE LUMINAIRE 0--W NEW DECORATIVE ROADWAY POLE AND LUMINAIRE : NEW DECORATIVE COMBINATION POLE AND LUMINAIRES 0 W •}c NEW DECORATIVE PEDESTRIAN POLE AND LUMINAIRE 00 RELOCATED LIGHT POLE AND LUMINAIRE W CO) O INDUCTION LOOP 0 -' CONDUIT/WIRE NOTE, SEE SCHEDULES ON SHEET E4 - --- 8 7 75 1 4 1 ___ ------ - - - - $ 8 11-- ILLUMINATION SYSTEM CONSTRUCTION NOTES: -- -- ---- - - - -- ABANDON W (D1CONSTRUCT Z DECORATIVE PEDESTRIAN LUMINAIRE, POLE AND T 7 ABANDON 8 FOUNDATION. SEE LUMINAIRE POLE SCHEDULE ON SHEET F FO go T FC 10 7 = . E2. LO -.a-- T H O2 CONSTRUCT DECORATIVE ROADWAY/PEDESTRIAN LUMINAIRES, 7 13 9 + P__._ -.__ i Q POLE AND FOUNDATION. SEE LUMINAIRE POLE SCHEDULE ON g SHEET E2. �� + ' ` ) 61 10 < 1 O3 CONSTRUCT DECORATIVE ROADWAY/PEDESTRIAN LUMINAIRES PLAN 1 (2) 1 3 5 V) AND POLE ON EXISTING FOUNDATION. CUT EXISTING I (2) 1 ANCHOR BOLTS AND EPDXY GROUT NEW 1.25 BOLTS IN SCALE IN FEET N 10 EXISTING FOUNDATION TO MATCH BOLT CIRCLE OF NEW 0 20 40 POLE. SEE LUMINAIRE POLE SCHEDULE ON SHEET E2. O CONSTRUCT JUNCTION BOX TYPE 1, CONCRETE PAD AND LIGHTING UNDERGROUND SYSTEM ADJACENT TO POLE PER SEE SHEET E3 COR STD. DETAILS J007 AND J008. 4 O REMOVE AND SALVAGE/RELOCATE EXISTING LUMINAIRE AND 84 1 2 1 FOUNDATION {) (2) POLE. 74 ONLY, NO POLE o 6 CONSTRUCT NEW FOUNDATION AND INSTALL RELOCATED 61 �' + o _ A A ^ ^ o A " LUMINAIRE AND DAVIT POLE PER COR STD. DETAIL J002. J VI'll_L I I Y I LLB 1 0 20 40 DESIGNED: C. SCHOTT DRAWN: V. RUBASHKA CHECKED SCALE: AS SHOWN ONE INC AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY O7 REMOVE AND SALVAGE EXISTING ELECTRICAL SERVICE. REMOVE EXISTING SERVICE FOUNDATION AND ABANDON CONDUIT CONNECTING TO ADJACENT JUNCTION BOX(ES). O REMOVE EXISTING ILLUMINATION SYSTEM WIRING AND ABANDON CONDUIT OR INSTALL PULL TAPE AS NOTED ON PLAN. REMOVE EXISTING JUNCTION BOX AND REPLACE WITH WSDOT y TYPE 8 JUNCTION BOX. 10 POINT OF CONNECTION AT PROPOSED PSE TRANSFORMER. SEE UG PLANS. COORDINATE SERVICE CONNECTION WITH PSE PER PSE REQUIREMENTS. 11 EXISTING LUMINAIRE TO BE REMOVED BY OTHERS. --v 12 EXISTING LUMINAIRE AND POLE TO REMAIN. 13 INTERCEPT EXISTING CONDUIT AND WIRING AND EXTEND INTO L-02 PROPOSED JUNCTION BOX. SPLICE/RESPLICE WIRES IN / TTO STA-2+27 - — JUNCTION BOX. TO STA 102447 HORIZONTAL- NAD 1983/1991 ► •� CITY OF RENTON DATUM Planning/Building/Public Works Dept. Approved For Construction Robert M. Hanson P.E. Date 14 REMOVE POLE FOUNDATION AND ABANDON CONDUIT. ITS SYSTEM CONSTRUCTION NOTES: FC PROVIDE AND INSTALL SMFO/ETHERNET SWITCH IN EXISTING OTRAFFIC SIGNAL CONTROLLER CABINET. TERMINATE SMFO CABLE(S) AT SWITCH. COORDINATE WITH COR TRAFFIC OPERATIONS STAFF DURING CUT -OVER. 2 PROVIDE AND INSTALL VAULT -TYPE 25-TA 3 PROVIDE AND INSTALL WSDOT TYPE 2 JUNCTION BOX. UTILIZE FOR TEMPORARY SPLICES DURING CONSTRUCTION. O4 SPLICE SMFO CABLES IN JUNCTION BOX/VAULT. SEE SPLICING DETAILS ON SHEEP E6. E10. O5 CONSTRUCT RISER ON EXISTING UTILITY POLE. DATE: NE 3rd / 4th CORRIDOR IMPROVEMENTS 12/27/12 PHASE 1 INTERSECTION IMPROVEMENTS FIELDSOOK: PAGE: ELECTRICAL PLAN - SHEET 1 El SHEET: OF: 24 43 ICIAIGI 1 I210181c_