HomeMy WebLinkAboutS-397704-POSED WALL DRAIN CROSSES JOINT UTILITY TRENCH SEE WATER PLANS H G --G ca Lu Z W J W 0 � FO Q le O Il M O CAP z w u- L 1,11g m, `• ■ W(F `1 SCALE IN FEET-'' a 2r40 I.D. TRENCHING QUANTITIES CONDUIT QUANTITIES CITY OF RENTON (COR)/ PUGET SOUND ENERGY CENTURY LINK COMCAST RENTON SCHOOL DISTRICT (PSE) (Q) (C) (RSD) DWG NO RUN A JOINT TRENCH (LF) DF 2 IN 3 IN 4 IN 6 IN 2 IN 4 IN 6 IN 2 IN ITS 3 IN (NOTE 1) SIGNAUILLUM (NOTE 2) NO. (LF) NO. (LF) NO. (LF) NO. (LF) NO. (LF) NO. (LF) NO. (LF) NOt(LF) NO. (LF) NO. NO. UG3 1 120 3 60 3 60 2 240' 5 600 2 1 UG3 2 5UG3 3 4 10 10 422�07 2 2UG3 _ UG3 5 115 1 4 UG3 UG3 6 7 5 10 F60 1 4 UG3 8 20 1 1 4 80 3 _. 2 40 -- 5 100 — ��--.4.._._.� UG3 9 15 1 15 UG3 10 10_ 2 UG3 11 120 4 480 3 '360 3 360 5 600 2 4 UG3 12 10- _ 4 _ UG3 13 10 1 UG3 14 20 2 40 - UG3 15 10 1 10 UG3 16 20 3 60 3 ; 60 5 ' 100 2 3 UG3 17 10 _ 1 10 ___..� -_ . �_ _____ �._..__ __-- 7,____ __ m UG3 18 5 3 _15 - ____. _ _--------- UG3 19 5 5 25. m. _ UG3 20 5 1 5 3 15 3 15 3 15 mm 3 85 ES �•� �, ®F wA,s�I < NE 4TH STREET CONDUIT QUANTITIES TRENCHING LD. QUANTITIES CITY OF RENTON (COR)/ PUGET SOUND ENERGY CENTURY LINK COMCAST RENTON SCHOOL DISTRICT (PSE) (Q) (C) (RSD) DWG RUN JOINT LATERAL ITS SIGNAUILLUM NO TRENCH TRENCH 2 IN 3 IN 4 IN 6 IN 2 IN 4 IN 6 IN 2 IN 3 IN (NOTE 1) (NOTE 2) NO. (LF) NO. (LF) NO. (LF) NO. '(LF) NO. (LF) NO. (LF) NO. (LF) NO. (LF) NO. NO. (LF) (LF) NO. (LF) UG3 21 10 3 30 UG3 22 15 _ 1 --�15 - 3 45 ` 3 �45 _ _ - _ 3 45 - 2 2 UG3 23 15 y. 1 15 UG3 24 10 1_._ __10 UG3 25 20 3 60 -- 3 60 _ 3 60 2 2 UG3 26 5 3 15 UG2 27 15 _ 1 15 UG2 28 UG2 29 15 SHEET TOTALS: 430 225 1 945 745 1-1 30 '' 1585' 1. INCLUDE ITS CONDUIT IN JOINT UTILITY TRENCH WHERE PRACTICAL, OTHERWISE COSNTRUCT ITS IN SEPARATE TRENCH. SEE ELECTRICAL PLANS FOR DETAILS. ITS CONDUIT PAID AS PART OF ITS SYSTEM BID ITEM(S). 2. INCLUDE TRAFFIC SIGNAUILLUMINATION CONDUIT IN JOINT UTILITY TRENCH WHERE PRACTICAL, OTHERWISE COSNTRUCT SIGNAL AND ILLUMINATION CONDUIT IN SEPARATE TRENCH. SEE ELECTRICAL PLANS FOR DETAILS. TRAFFIC SIGNAL AND ILLUMINATION CONDUIT PAID AS PART OF RESPECTIVE TRAFFIC SIGNAL/ILLUMINATION SYSTEM BID ITEM(S). Parametrix 1019 39TH AVENUE SE, SUITE 900 PUYALLUP, WASHINGTON 98374 T.253.604.6600 F.253.604.6799 www.parametdx.com 3 IRECORD DRAWINGS ECS I 11 3 1 , 2 REVISED NOTES ECS 12 31 1 REVISED COMCAST VAULT LOCATION, EXISTING ECS 12/31 WATER MAIN LOCATION AND PROPOSED WATER ALIGNMENT NO. REVISION BY DATE L G � do= 2. SEE RIGHT OF PROFILE SHEETS Fj UTILITY EASEMENTS. PROFILES. 3. SEE DWGS PP1 THRU PP4 FOR STORM DRAIN PLAN AND 4. STORM DRAIN CROSSING ELEVATION IS AT CENTER OF TREACA AND CENTER OF i- 1- ZL DENOTES TRENCH RUN NUMBER. SEE DWG UGX FOR TRENCH r CONDUIT SCHEDULE. INSTALL VAULT - COMCAST 0 INSTALL PEDESTAL RISER - COMCAST 10xlat C3 INSTALL VAULT - COMCAST TYPE 9 INCH DIA. PO CONSTRUCTED BY PSE ��INSTALL VAULT - PSE TYPE 3642 aINSTALL VAULT - PSE TYPE 5106 i , 1 INSTALL VAULT - rSE r E 132-4r- INSTALL VAULT - CENTURY LINK TYPE 264-TA 01 INSTALL VAULT - CENTURY LINK TYPE 910 - I VAN ko" SEE ELECTRICAL PLANsm EXISTING UNDERGROUND COR & RSD CONDUIT/FIBER-OPTI BE TEMPORARILY RELOCATED OR OTHERWISE PROTECTED BY CONTRACTOR DURING CONSTRUCTION. CONSTRUCT 4" CONDUIT RISER AND CAP 3" CONDUIT AT BASE OF POLE. CONSTRUCT CONDUIT 1. RISER(S) :r ON POLE r • SERVING UTILITY REQUIREMENTS EXISTING UTILITY TO is REMOVED BY SERVING EXISTING UTILITY TO REMAIN. i INTERCEPT AND COORDINATE , • WITH SERVING f `55 EXISTING POLE O BE TEMPORARILY SUPPORTED BY PSE FOR UP TO • REGULAR WORK HOURS TO ACCOMMODATE CONSTRUCTION, INSPECTION. AND BACKFILL OF ADJACENT JOINT TRENCH.UTILITY CONTRACTOR PROVIDE i' DAYS NOTICETO PSE AND COORDINATE WITH ALL t UTILITIES TO PROVIDE CONDUIT INSPECTIONS AND APPROVALS CONCURRENT "POLE SUPPORT. OVERSET EXISTING UTILITY AND COORDINWITH ATE CUTOVER ►i 1. PROPOSED LUMINAIRE LOCATION, ELECTRICAL PLANS. � RlIIil,102:E.3�0il,1021L it - 14HE _* -3-agm REVISED To CONFORM WITH THIS DRAWING HAS BEEN REVISED TO REFLECT INFORMATION PROVIDED BY THE CONSTRUCTION CONTRACTOR, OBSERVING ENGINEER, AND PROJECT ENGINEER DEFINING KNOWN CONSTRUCTION RECORD DIFFERENCES • ON ORIGINAL CONSTRUCTIONDOCUMENTS TO THOSE CONSTRUCTED. THE INFORMATIONPROVIDED ON ••• I S ASSUMED TO BE CORRECT AND HAS NOT BEEN VERIFIED BY THE ENGINEER, WHO IS UNDER NO OBLIGATION OR DUTY TO VERIFY SUCH ACCURACY AND/OR COMPLETENESS. SAID ENGINEER, BY . • PROFESSEALSIONAL ON DRAWING,r THE REVISION(S)TO VERIFY THAT THE CHANGES AS DEFINED BY THESE RECORDSr• NOT DAM APPEAR TO BE ADVERSETO THE PLANNED USE AND/OR INTENT OF DESIGN.• WARRANTY HEREIN FOR THE ACCURACY OF • •• _ .- SURVEYED: DESIGNED: C. SCHOTT DRAWN: J. BEfZVOG CHECKED: SCALE: AS SHOWN ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY