Loading...
HomeMy WebLinkAboutT-397702Lil Q z C) LEI 0 N 1 w � 00+0� 101 +00 7 02+0o WH ITMAN CT NE 1 ------ l -- -- I _._.__-i-- I Z W 2 LU O w a O O V 4a L. M W Z � x x -- --------------- I I� L I. a Ix P I r1l FF--:=-� I I► I J� I I I -m nod-MAJAP01 3 KM SCALE IN FEET 0 20 40 R 5 77--7� r IW 1P3+00:::::::::::::::::::::::104+00::::::::::::::.: (1) • W W to - r I� 90 LU J 2 V aC 90 1� 92 I'LL I I C=::] E777T=1-111 ----------------------------- n o LUMINAIRE SCHEDULE POLE NO ® STATION OFFSET POLE TYPE FOUNDATION ROADWAY LUMINAIRE PEDESTRIAN LUMINAIRE POLE ID NO NOTES NUMBER MH ORIENT CIRCUIT NUMBER MH ORIENT CIRCUIT L1 2+20 40.01T EX ROAD (8) 101 35' 0' 1 7939 L RELOCATED POLE L-02 FROM STA 10+01 RT L2 2+96 36.5'LT PED (6) (6) 1 201 14' 0' 2 7941 LN L3 3+56 36.5LT COMB (7) (7) 102 30' 0' 1 202 14' 180' 2 7943 LN L4 4+14 36.5'LT PED (6) (6) 203 14' 180' 2 7945 L L5 4+71 36.5'LT COMB (7) (7) 103 30' 0' 1 204 14' 180' 2 7947 LN L6 5+48 36.5'LT PED (6) (6) 205 14' 180' 2 7949 L L7 5+93 36.5LT COMB (7) (7) 104 30' 0' 1 206 14' 180' 2 7951 LN L8 6+50 36.5'LT PED (6) (6) 207 14' 180' 2 7953 L 1 SEE SIGNAL POLE SCHEDULE ON SHEET E6 105 30' 0' 1 208 14' 0' 2 7955 LN 2 106 30' 90' 1 209 14' 45' 2 7957 LN L9 8+25 36.5'LT PED (6) (6) 210 14' 180' 2 7959 L L10 8+65 36.5'LT COMB (7) (7) 107 30' 0' 1 211 14' 180' 2 7961 LN L11 9+93 36.51T DELETED (8)(9) ';996-2 ON L12 2+39 49'RT COMB (7) (2) 301 30' 0' 3 401 14' 0' 4 7963 LN (1) 1-13 3+66 41'RT COMB (7) (2) 302 30' 0' 3 402 14' 0' 4 7963 LN (1) L14 4+21 41'RT PED (6) (6) 403 14' 0' 4 7967 L L15 4+57 41'RT COMB (7) (2) 303 30' 0' 3 404 14' 0' 4 7969 LN (1) L16 5+09 41'RT PED (6) (6) 405 14' 0' 4 7971 L L17 5+62 41'RT COMB (7) (2) 304 30' 0' 3 406 14' 0' 4 7973 LN (1) L18 6+17 47'RT PED (6) (6) 407 14' 0' 4 7975 L L19 6+71 52'RT COMB (7) (2) 305 30' 0' 3 408 14' 0' 4 7977 LN (1) 4 SEE SIGNAL POLE SCHEDULE ON SHEET E6 306 30' 90' 3 409 14' 45' 4 7979 LN 3 307 30' 0' 3 410 14' 180' 4 7981 LN L20 8+40 46'RT PED (6) (6) 411 14' 180' 4 7983 L L21 8+89 46'RT COMB (7) (2) 308 30' 0' 3 412 14' 180' 4 7985 LN RELOCATE EX POLE L-01 TO L11 L22 9+45 46'RT PED (6) (6) 413 14' 180' 4 7987 L L23 10+01 46'RT COMB (7) (2) 309 30' 0' 3 414 14' 180' 4 7989 LN RELOCATE EX POLE L-02 TO L1 L50 102+10 27'RT (4) (5) 501 N/A EX (3) EX RELOC RELOCATED POLE FROM STA 9+44 RT L51 102+47 1 28'RT 1 (4) (5) 1 502 N/A EX (3) EX RELOC RELOCATED POLE FROM STA 9+77 RT �1� REMOVE AND SALVAGE EX POLE AND LUMINAIRE 2 INSTALL ON EXISTING FOUNDATION WITH EPDXY GROUTED ANCHOR BOLTS TO MATCH BOLT CIRCLE OF NEW POLE. �3� SPLICE TO EX USPS PARKING LOT ILLUM. CIRCUIT 4 RELOCATED FROM EXISTING MAIL DROP LANE �gLES SC' oFj� �O CALL 48 HOURS BEFORE YOU DIG 1-800-424-5555 �5� 6 (7) TIB # 8-1-102(033)-1 MATCH EXISTING PER COR DECORATIVE PEDESTRIAN LUMINAIRE AND POLE STD PLAN 005 EXCEPT MODIFY FOUNDATION DEPTH TO 4'-0". PER COR DECORATIVE ARTERIAL STREET LIGHTING POLE STD. PLAN 004, EXCEPT MODIFY MOUNTING HEIGHT AS NOTED IN SCHEDULE AND MODIFY FOUNDATION DEPTH TO 4'-6". 1019 39TH AVENUE SE, SUITE 100 PUYALLUP, WASHINGTON 98374 T.253.604.6600 F.253.604.6799 www.parametdx.com (8) PER COR STD PLANS J002 AND J007, WITH MODIFICATIONS AS NECESSARY TO ACCOMMODATE REINSTALLATION OF EXISTING POLE. (9) CUT ANCHOR BOLTS FLUSH WITH FOUNDATION. 1 2 (RECORD DRAWINGS I ECS 11 3 14 1 IREVISED LUMINAIRE FOUNDATION DEPTHS ECS 12 27 i on REVISION SURVEYED: DESIGNED: C. SCHOTT DRAWN: V. RUBASHKA CHECKED: SCALE: AS SHOWN ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY USPS ELECTRICAL NOTES: 000NSTRUCT FOUNDATION WITH NEW ANCHOR BOLTS TO MATCH EXISTING USPS LIGHT POLE FOUNDATION. INSTALL RELOCATED USPS LIGHT POLE AND LUMINAIRE. 20 LOCATE, INTERCEPT AND EXTEND EXISTING USPS ILLUMINATION CONDUIT AND WIRING TO NEW TYPE 1 JUNCTION BOX WITH LOCKING LID. REPLACE/RESTORE EXISTING WIRING CONTINUOUS, WITHOUT SPLICE, BETWEEN ADJACENT EXISTING LUMINAIRE AND NEAREST EXISTING JUNCTION. SPLICE NEW WIRING PER CONDUIT RUN NO. 90 TO EXISTING CIRCUIT IN NEW TYPE 1 JUNCTION BOX. O3 INTERCEPT AND EXTEND EXISTING CONDUIT TO RELOCATED GATE OPERATOR LOCATION. O4 REMOVE WIRING FROM EXISTING CONDUIT AND REPLACE WITH NEW WIRING CONTINUOUS WITHOUT SPLICE BETWEEN EXISTING POINT OF CONNECTION AND RELOCATED GATE OPERATOR VIA EXISTING AND EXTENDED CONDUIT. OREMOVE AND REINSTALL GATE OPERATOR AND ASSOCIATED EQUIPMENT AND RESTORE WIRING. REVISED TO CONFORM WITH CONSTRUCTION RECORDS DAM 1 /3/14 BYI ECS THIS DRAWING HAS BEEN REVISED TO REFLECT INFORMATION PROVIDED BY THE CONSTRUCTION CONTRACTOR, OBSERVING ENGINEER, AND PROJECT ENGINEER DEFINING KNOWN DIFFERENCES BETWEEN THE FACILITIES SHOWN ON THE ORIGINAL CONSTRUCTION DOCUMENTS TO THOSE CONSTRUCTED. THE INFORMATION PROVIDED ON THESE RECORDS, HAS BEEN ASSUMED TO BE CORRECT AND HAS NOT BEEN VERIFIED BY THE ENGINEER, WHO IS UNDER NO OBUGATION OR DUTY TO VERIFY SUCH ACCURACY AND/OR COMPLETENESS. SAID ENGINEER, BY PLACING HER/HIS PROFESSIONAL SEAL ON THIS DRAWING, HAS REVIEWED THE REVISION(S) TO VERIFY THAT THE CHANGES AS DEFINED BY THESE RECORDS DO NOT APPEAR TO BE ADVERSE TO THE PLANNED USE AND/OR INTENT OF THE ORIGINAL DESIGN. THERE IS NO WARRANTY HEREIN FOR THE ACCURACY OF THE CHANGES SHOWN, NOR ASSURANCE THAT AL. DIFFERENCES TO THE ORIGINAL DRAWING HAVE BEEN IDENTIFIED. .. CITY OF RENTON Planning/Building/Public Works Dept. Approved For Construction Robert M. Hanson P.E. Date NE 3rd / 4th CORRIDOR IMPROVEMENTS 12/27/12 PHASE 1 INTERSECTION IMPROVEMENTS FIELDBOOK: PAGE: DRAWING NO: ELECTRICAL PLAN - SHEET 2 E2 AND LUMINAIRE POLE SCHEDULE SHEET: OF: 25 43