HomeMy WebLinkAboutT-397702Lil
Q
z
C)
LEI
0
N 1
w � 00+0� 101 +00 7 02+0o WH ITMAN CT NE
1 ------ l -- -- I _._.__-i--
I
Z
W
2
LU
O
w
a
O
O
V
4a
L.
M
W
Z
�
x
x --
---------------
I
I�
L
I.
a
Ix
P
I r1l FF--:=-�
I
I►
I
J�
I
I
I
-m nod-MAJAP01
3
KM
SCALE IN FEET
0 20 40
R
5
77--7�
r
IW
1P3+00:::::::::::::::::::::::104+00::::::::::::::.: (1)
• W
W
to
- r
I�
90 LU
J
2 V
aC
90 1�
92
I'LL I I C=::] E777T=1-111
-----------------------------
n o
LUMINAIRE SCHEDULE
POLE
NO
®
STATION
OFFSET
POLE
TYPE
FOUNDATION
ROADWAY LUMINAIRE
PEDESTRIAN LUMINAIRE
POLE
ID NO
NOTES
NUMBER
MH
ORIENT
CIRCUIT
NUMBER
MH
ORIENT
CIRCUIT
L1
2+20
40.01T
EX ROAD
(8)
101
35'
0'
1
7939 L
RELOCATED POLE L-02 FROM STA 10+01 RT
L2
2+96
36.5'LT
PED (6)
(6)
1
201
14'
0'
2
7941 LN
L3
3+56
36.5LT
COMB (7)
(7)
102
30'
0'
1
202
14'
180'
2
7943 LN
L4
4+14
36.5'LT
PED (6)
(6)
203
14'
180'
2
7945 L
L5
4+71
36.5'LT
COMB (7)
(7)
103
30'
0'
1
204
14'
180'
2
7947 LN
L6
5+48
36.5'LT
PED (6)
(6)
205
14'
180'
2
7949 L
L7
5+93
36.5LT
COMB (7)
(7)
104
30'
0'
1
206
14'
180'
2
7951 LN
L8
6+50
36.5'LT
PED (6)
(6)
207
14'
180'
2
7953 L
1
SEE SIGNAL POLE
SCHEDULE ON SHEET E6
105
30'
0'
1
208
14'
0'
2
7955 LN
2
106
30'
90'
1
209
14'
45'
2
7957 LN
L9
8+25
36.5'LT
PED (6)
(6)
210
14'
180'
2
7959 L
L10
8+65
36.5'LT
COMB (7)
(7)
107
30'
0'
1
211
14'
180'
2
7961 LN
L11
9+93
36.51T
DELETED
(8)(9)
';996-2
ON
L12
2+39
49'RT
COMB (7)
(2)
301
30'
0'
3
401
14'
0'
4
7963 LN
(1)
1-13
3+66
41'RT
COMB (7)
(2)
302
30'
0'
3
402
14'
0'
4
7963 LN
(1)
L14
4+21
41'RT
PED (6)
(6)
403
14'
0'
4
7967 L
L15
4+57
41'RT
COMB (7)
(2)
303
30'
0'
3
404
14'
0'
4
7969 LN
(1)
L16
5+09
41'RT
PED (6)
(6)
405
14'
0'
4
7971 L
L17
5+62
41'RT
COMB (7)
(2)
304
30'
0'
3
406
14'
0'
4
7973 LN
(1)
L18
6+17
47'RT
PED (6)
(6)
407
14'
0'
4
7975 L
L19
6+71
52'RT
COMB (7)
(2)
305
30'
0'
3
408
14'
0'
4
7977 LN
(1)
4
SEE SIGNAL POLE
SCHEDULE ON SHEET E6
306
30'
90'
3
409
14'
45'
4
7979 LN
3
307
30'
0'
3
410
14'
180'
4
7981 LN
L20
8+40
46'RT
PED (6)
(6)
411
14'
180'
4
7983 L
L21
8+89
46'RT
COMB (7)
(2)
308
30'
0'
3
412
14'
180'
4
7985 LN
RELOCATE EX POLE L-01 TO L11
L22
9+45
46'RT
PED (6)
(6)
413
14'
180'
4
7987 L
L23
10+01
46'RT
COMB (7)
(2)
309
30'
0'
3
414
14'
180'
4
7989 LN
RELOCATE EX POLE L-02 TO L1
L50
102+10
27'RT
(4)
(5)
501
N/A
EX (3)
EX RELOC
RELOCATED POLE FROM STA 9+44 RT
L51
102+47
1 28'RT
1 (4)
(5)
1
502
N/A
EX (3)
EX RELOC
RELOCATED POLE FROM STA 9+77 RT
�1� REMOVE AND SALVAGE EX POLE AND LUMINAIRE
2 INSTALL ON EXISTING FOUNDATION WITH EPDXY GROUTED
ANCHOR BOLTS TO MATCH BOLT CIRCLE OF NEW POLE.
�3� SPLICE TO EX USPS PARKING LOT ILLUM. CIRCUIT
4 RELOCATED FROM EXISTING MAIL DROP LANE
�gLES SC'
oFj� �O
CALL 48 HOURS
BEFORE YOU DIG
1-800-424-5555
�5�
6
(7)
TIB # 8-1-102(033)-1
MATCH EXISTING
PER COR DECORATIVE PEDESTRIAN LUMINAIRE AND POLE
STD PLAN 005 EXCEPT MODIFY FOUNDATION DEPTH TO 4'-0".
PER COR DECORATIVE ARTERIAL STREET LIGHTING POLE
STD. PLAN 004, EXCEPT MODIFY MOUNTING HEIGHT AS NOTED IN
SCHEDULE AND MODIFY FOUNDATION DEPTH TO 4'-6".
1019 39TH AVENUE SE, SUITE 100
PUYALLUP, WASHINGTON 98374
T.253.604.6600 F.253.604.6799
www.parametdx.com
(8) PER COR STD PLANS J002 AND J007, WITH
MODIFICATIONS AS NECESSARY TO ACCOMMODATE
REINSTALLATION OF EXISTING POLE.
(9) CUT ANCHOR BOLTS FLUSH WITH FOUNDATION.
1 2 (RECORD DRAWINGS I ECS 11 3 14
1 IREVISED LUMINAIRE FOUNDATION DEPTHS ECS 12 27
i on
REVISION
SURVEYED:
DESIGNED:
C. SCHOTT
DRAWN:
V. RUBASHKA
CHECKED:
SCALE:
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
USPS ELECTRICAL NOTES:
000NSTRUCT FOUNDATION WITH NEW ANCHOR BOLTS TO
MATCH EXISTING USPS LIGHT POLE FOUNDATION. INSTALL
RELOCATED USPS LIGHT POLE AND LUMINAIRE.
20 LOCATE, INTERCEPT AND EXTEND EXISTING USPS
ILLUMINATION CONDUIT AND WIRING TO NEW TYPE 1
JUNCTION BOX WITH LOCKING LID. REPLACE/RESTORE
EXISTING WIRING CONTINUOUS, WITHOUT SPLICE, BETWEEN
ADJACENT EXISTING LUMINAIRE AND NEAREST EXISTING
JUNCTION. SPLICE NEW WIRING PER CONDUIT RUN NO. 90
TO EXISTING CIRCUIT IN NEW TYPE 1 JUNCTION BOX.
O3 INTERCEPT AND EXTEND EXISTING CONDUIT TO RELOCATED
GATE OPERATOR LOCATION.
O4 REMOVE WIRING FROM EXISTING CONDUIT AND REPLACE WITH
NEW WIRING CONTINUOUS WITHOUT SPLICE BETWEEN EXISTING
POINT OF CONNECTION AND RELOCATED GATE OPERATOR VIA
EXISTING AND EXTENDED CONDUIT.
OREMOVE AND REINSTALL GATE OPERATOR AND ASSOCIATED
EQUIPMENT AND RESTORE WIRING.
REVISED TO CONFORM WITH
CONSTRUCTION RECORDS
DAM 1 /3/14 BYI ECS
THIS DRAWING HAS BEEN REVISED TO REFLECT INFORMATION PROVIDED BY THE CONSTRUCTION CONTRACTOR, OBSERVING ENGINEER, AND PROJECT ENGINEER DEFINING KNOWN
DIFFERENCES BETWEEN THE FACILITIES SHOWN ON THE ORIGINAL CONSTRUCTION DOCUMENTS TO THOSE CONSTRUCTED. THE INFORMATION PROVIDED ON THESE RECORDS, HAS BEEN
ASSUMED TO BE CORRECT AND HAS NOT BEEN VERIFIED BY THE ENGINEER, WHO IS UNDER NO OBUGATION OR DUTY TO VERIFY SUCH ACCURACY AND/OR COMPLETENESS. SAID
ENGINEER, BY PLACING HER/HIS PROFESSIONAL SEAL ON THIS DRAWING, HAS REVIEWED THE REVISION(S) TO VERIFY THAT THE CHANGES AS DEFINED BY THESE RECORDS DO NOT
APPEAR TO BE ADVERSE TO THE PLANNED USE AND/OR INTENT OF THE ORIGINAL DESIGN. THERE IS NO WARRANTY HEREIN FOR THE ACCURACY OF THE CHANGES SHOWN, NOR
ASSURANCE THAT AL. DIFFERENCES TO THE ORIGINAL DRAWING HAVE BEEN IDENTIFIED.
.. CITY OF
RENTON
Planning/Building/Public Works Dept.
Approved For Construction
Robert M. Hanson P.E. Date
NE 3rd / 4th CORRIDOR IMPROVEMENTS 12/27/12
PHASE 1 INTERSECTION IMPROVEMENTS FIELDBOOK:
PAGE:
DRAWING NO:
ELECTRICAL PLAN - SHEET 2 E2
AND LUMINAIRE POLE SCHEDULE SHEET: OF:
25 43