Loading...
HomeMy WebLinkAboutR-397725IRRIGATION NOTES: LLI Q z C) W 0 1� H Z W 2 W O W (L O DC O C.� L M W Z 0 Fo AgLES Sc WAs�I� �O 33242 4 ISTER SHELL STATION I` O I WALGREENS CALL 48 HOURS BEFORE YOU DIG 1-800-424-5555 I -- FO REVISED TO CONFORM WITH CONSTRUCTION RECORDS DATE= 1 /3/14 BY, ECS T1B # 8-1-102(033)-1 1019 39TH AVENUE SE, SUITE 100 PUYALLUP, WASHINGTON 98374 T.253.604.6600 F.253.604.6799 www.parametrix.com NE 4TH STREET W NO WALGREENS RECORD DRAWINGS TACO TIME R/W SCALE.v 1 REVISION Sleeve �G Plan is diagrammatic. Locate mainline 4 equipment in planter strip to north. VACANT — — — — — — — - W ne W co Uj W U) co Q ca W - — --- Z ®J Q 1. SEE SHEET IR4 FOR CONSTRUCTION DETAILS & NOTES. 2. CONTRACTOR SHALL VERIFY SPECIFIC IRRIGATION CONTROLLER LOCATION PRIOR TO CONSTRUCTION. 3. PLAN IS DIAGRAMMATIC. VARIATIONS IN HEAD LOCATIONS ON PLAN IS FOR THE SAKE OF GRAPHIC CLARITY. 4. MAINLINE, LATERALS, AND SLEEVING ARE SCHEMATIC ONLY AND SHALL OCCUR IN PLANTING AREAS UNLESS SLEEVING IS SHOWN. 5. CONTRACTOR SHALL MAKE FIELD ADJUSTMENTS AS NEEDED TO OBTAIN FULL COVERAGE. DESIGNERS RESERVES THE RIGHT TO MAKE NOZZLE CHANGES AS NEEDED AT NO ADDITIONAL COST. CONTRACTOR SHALL ADJUST HEAD POSITIONS AND ADD OR DELETE HEADS AS NEEDED DEPENDING ON ACTUAL FIELD CONDITIONS. LEGEND: SY„I. UE5CR11='TI0N Lk Rairibird 1806 - 10 Series 0 Lk Ra iribird 1806 - 10 Series T ® Rairibird 1806 - 10 Series H Rainbird 1806 - 15 Series 0 ® Rainbird 1806 - 15 Series H ElRainbird 1812 - 15 Series EST ® Rainbird 1812 - 15 Series 4 X 30 SST ORainbird n5 - P Electric Zone valve PROTECT & RESTORE EXISTING IRRIGATION SYSTEM o.PROTECT, RESTORE & EXTEND EXISTINIf Nr THIS DRAWING HAS BEEN REVISED TO REFLECT INFORMATION PROVIDED BY THE CONSTRUCTION CONTRACTOR, OBSERVING ENGINEER, AND PROJECT ENGINEER DEFINING KNOWN DIFFERENCES BETWEEN THE FACILITIES SHOWN ON THE ORIGINAL CONSTRUCTION DOCUMENTS TO THOSE CONSTRUCTED. THE INFORMATION PROVIDED ON THESE RECORDS, HAS BEEN ASSUMED TO BE CORRECT AND HAS NOT BEEN VERIFIED BY THE ENGINEER, WHO IS UNDER NO OBLIGATION OR DUTY TO VERIFY SUCH ACCURACY AND/OR COMPLETENESS. SAID ENGINEER, BY PLACING HER/HIS PROFESSIONAL SEAL ON THIS DRAWING, HAS REVIEWED THE REVISION(S) TO VERIFY THAT THE CHANGES AS DEFINED BY THESE RECORDS DO NOT APPEAR TO BE ADVERSE TO THE PLANNED USE AND/OR INTENT OF THE ORIGINAL DESIGN. THERE IS NO WARRANTY HEREIN FOR THE ACCURACY OF THE CHANGES SHOWN, NOR ASSURANCE THAT ALL DIFFERENCES TO THE ORIGINAL DRAWING HAVE BEEN IDENTIFIED. SURVEYED: SCALE: DATE: VERTICAL- ""V° 79� NE 3rd / 4th CORRIDOR IMPROVEMENTS / / DESIGNED: AS SHOWN HORIZONTAL NAD 1983/1991 CITY OF 8 $ 12 D. SANDENO � �- FIELDBOOK: RENTON PHASE 1 INTERSECTION IMPROVEMENTS PAGE: DRAWN: D. SANDENO ONE INCH DATUM Planning/Building/Public Works Dept. DRAWING NO: ECS 1 3 14 CHECKED: AT FULL SCALE Approved For Construction IRRIGATION I R 1 IF NOT ONE INCH BY DATE APPR APPROVED: SCALE ACCORDINGLY DI A N SHEET: OF: Robert M. Hanson P.E. Date (��/� 40 43 MENNNNNE