HomeMy WebLinkAboutR-397725IRRIGATION NOTES:
LLI
Q
z
C)
W
0
1�
H
Z
W
2
W
O
W
(L
O
DC
O
C.�
L
M
W
Z
0
Fo
AgLES Sc
WAs�I� �O
33242 4
ISTER
SHELL
STATION
I` O
I
WALGREENS
CALL 48 HOURS
BEFORE YOU DIG
1-800-424-5555
I -- FO
REVISED TO CONFORM WITH
CONSTRUCTION RECORDS
DATE= 1 /3/14 BY, ECS
T1B # 8-1-102(033)-1
1019 39TH AVENUE SE, SUITE 100
PUYALLUP, WASHINGTON 98374
T.253.604.6600 F.253.604.6799
www.parametrix.com
NE 4TH STREET
W
NO
WALGREENS
RECORD DRAWINGS
TACO TIME
R/W
SCALE.v
1
REVISION
Sleeve �G
Plan is diagrammatic.
Locate mainline 4 equipment
in planter strip to north.
VACANT
— — — — — — — - W
ne W
co
Uj
W
U)
co
Q
ca
W
- — --- Z
®J
Q
1. SEE SHEET IR4 FOR CONSTRUCTION
DETAILS & NOTES.
2. CONTRACTOR SHALL VERIFY SPECIFIC
IRRIGATION CONTROLLER LOCATION PRIOR
TO CONSTRUCTION.
3. PLAN IS DIAGRAMMATIC. VARIATIONS IN
HEAD LOCATIONS ON PLAN IS FOR THE
SAKE OF GRAPHIC CLARITY.
4. MAINLINE, LATERALS, AND SLEEVING ARE
SCHEMATIC ONLY AND SHALL OCCUR IN
PLANTING AREAS UNLESS SLEEVING IS
SHOWN.
5. CONTRACTOR SHALL MAKE FIELD
ADJUSTMENTS AS NEEDED TO OBTAIN
FULL COVERAGE. DESIGNERS RESERVES
THE RIGHT TO MAKE NOZZLE CHANGES
AS NEEDED AT NO ADDITIONAL COST.
CONTRACTOR SHALL ADJUST HEAD
POSITIONS AND ADD OR DELETE HEADS
AS NEEDED DEPENDING ON ACTUAL
FIELD CONDITIONS.
LEGEND:
SY„I. UE5CR11='TI0N
Lk
Rairibird 1806 - 10 Series 0
Lk
Ra iribird 1806 - 10 Series T
®
Rairibird 1806 - 10 Series H
Rainbird 1806 - 15 Series 0
®
Rainbird 1806 - 15 Series H
ElRainbird
1812 - 15 Series EST
®
Rainbird 1812 - 15 Series 4 X 30 SST
ORainbird
n5 - P Electric Zone valve
PROTECT & RESTORE EXISTING IRRIGATION
SYSTEM
o.PROTECT, RESTORE & EXTEND EXISTINIf
Nr
THIS DRAWING HAS BEEN REVISED TO REFLECT INFORMATION PROVIDED BY THE CONSTRUCTION CONTRACTOR, OBSERVING ENGINEER, AND PROJECT ENGINEER DEFINING KNOWN
DIFFERENCES BETWEEN THE FACILITIES SHOWN ON THE ORIGINAL CONSTRUCTION DOCUMENTS TO THOSE CONSTRUCTED. THE INFORMATION PROVIDED ON THESE RECORDS, HAS BEEN
ASSUMED TO BE CORRECT AND HAS NOT BEEN VERIFIED BY THE ENGINEER, WHO IS UNDER NO OBLIGATION OR DUTY TO VERIFY SUCH ACCURACY AND/OR COMPLETENESS. SAID
ENGINEER, BY PLACING HER/HIS PROFESSIONAL SEAL ON THIS DRAWING, HAS REVIEWED THE REVISION(S) TO VERIFY THAT THE CHANGES AS DEFINED BY THESE RECORDS DO NOT
APPEAR TO BE ADVERSE TO THE PLANNED USE AND/OR INTENT OF THE ORIGINAL DESIGN. THERE IS NO WARRANTY HEREIN FOR THE ACCURACY OF THE CHANGES SHOWN, NOR
ASSURANCE THAT ALL DIFFERENCES TO THE ORIGINAL DRAWING HAVE BEEN IDENTIFIED.
SURVEYED: SCALE: DATE:
VERTICAL- ""V° 79� NE 3rd / 4th CORRIDOR IMPROVEMENTS / /
DESIGNED: AS SHOWN HORIZONTAL NAD 1983/1991 CITY OF 8 $ 12
D. SANDENO � �- FIELDBOOK:
RENTON PHASE 1 INTERSECTION IMPROVEMENTS PAGE:
DRAWN:
D. SANDENO ONE INCH DATUM Planning/Building/Public Works Dept. DRAWING NO:
ECS 1 3 14 CHECKED: AT FULL SCALE Approved For Construction IRRIGATION I R 1
IF NOT ONE INCH
BY DATE APPR APPROVED: SCALE ACCORDINGLY DI A N SHEET: OF:
Robert M. Hanson P.E. Date (��/� 40 43
MENNNNNE