HomeMy WebLinkAboutPRE15-000628 (R- Dalpay Short Plat 4-lots)H:\CED\Planning\Current Planning\PREAPPS\2015 Preapps\15-000551 PREAPPLICATION MEETING FOR DALPAY ASSOCIATES SHORT PLAT PRE 15-000628 CITY OF RENTON Department of Community & Economic Development Planning Division September 24, 2015 Contact Information: Planner: Rocale Timmons, 425.430.7219 Public Works Plan Reviewer: Rohini Nair, 425.430.7298 Fire Prevention Reviewer: Corey Thomas, 425.430.7024 Building Department Reviewer: Craig Burnell, 425.430.7290 Please retain this packet throughout the course of your project as a reference. Consider giving copies of it to any engineers, architects, and contractors who work on the project. You will need to submit a copy of this packet when you apply for land use and/or environmental permits. Pre-screening: When you have the project application ready for submittal, call and schedule an appointment with the project manager to have it pre-screened before making all of the required copies. The pre-application meeting is informal and non-binding. The comments provided on the proposal are based on the codes and policies in effect at the time of review. The applicant is cautioned that the development regulations are regularly amended and the proposal will be formally reviewed under the regulations in effect at the time of project submittal. The information contained in this summary is subject to modification and/or concurrence by official decision-makers (e.g., Hearing Examiner, Planning Director, Development Services Director, Department of Community & Economic Development Administrator, Public Works Administrator and City Council). H:\CED\Planning\Current Planning\PREAPPS\2015 Preapps\15-000551 M E M O R A N D U M DATE: September 24, 2015 TO: Pre-Application File No. 15-000628 FROM: Rocale Timmons, Senior Planner SUBJECT: Dalpay Associates Short Plat General: We have completed a preliminary review of the pre-application for the above-referenced development proposal. The following comments on development and permitting issues are based on the pre-application submittals made to the City of Renton by the applicant and the codes in effect on the date of review. The applicant is cautioned that information contained in this summary may be subject to modification and/or concurrence by official decision-makers (e.g., Hearing Examiner, Community & Economic Development Administrator, Public Works Administrator, Planning Director, Development Services Director, and City Council). Review comments may also need to be revised based on site planning and other design changes required by City staff or made by the applicant. The applicant is encouraged to review all applicable sections of the Renton Municipal Code. The Development Regulations are available for purchase for $50.00 plus tax, from the Finance Division on the first floor of City Hall or online at www.rentonwa.gov. Project Proposal: The subject property is located south of NE 19th St, west of Union Ave NE, at 1801 Redmond Ave NE. The proposal is to subdivide Lot 5 of the Dalpay Short Plat (LUA03-125) into 4 lots for the future construction of single family residences. The subject property totals 72,332 square feet in area, and is zoned Residential-6 dwelling units per net acre (R-6). Access to Lot 1 is proposed via an extension of Redmond Pl NE, a private access road which serves Lots 1-4 of the original Dalpay Short Plat. Proposed Lots 2-4 would be served via an extension of an access easement off of the Redmond Ct NE cul-de-sac of from the neighboring plat to the west (Veldyke II Short Plat, LUA09-058). There is an identified Class 4 stream located in the center of the site which was placed in a Native Growth Protection Easement as part of the original short plat approval. There are also sensitive and critical slopes located on the site. Current Use: The site is undeveloped with clumps of mature trees in various locations. Zoning: The property is located within the Residential-6 (R-6) zoning designation. The R-6 zone was established for single family residential dwellings allowing a range of three (3) to six (6) dwelling units per net acre (du/ac). The R-6 is intended to implement the Residential Medium Density Land Use Comprehensive Plan designation. Development in the R-6 Zone is intended to be single family residential at moderate density. Detached single family residential dwelling units are a permitted uses within the R-6 zoning designation. Density: The area of public and private streets and critical areas would be deducted from the gross site area to determine the “net” site area prior to calculating density. However, the exact area of the land within right-of-way dedications and access easements on site were not provided with the pre-application materials, therefore the net density could not be calculated. H:\CED\Planning\Current Planning\PREAPPS\2015 Preapps\15-000551 A density worksheet would be required at the time of formal land use application for each zone. The applicant would be required to demonstrate compliance with the net density requirements of the zone at the time of formal application. Development Standards: The project would be subject to RMC 4-2-110A, “Development Standards for Single Family Zoning Designations” effective at the time of complete application (noted as “R-8 standards” herein). Minimum Lot Size, Width and Depth – The minimum lot size permitted in the R-6 zone, is 7,000 square feet for parcels being subdivided. Minimum lot width is 60 feet for interior lots and 70 feet for corner lots; minimum lot depth is 90 feet. All lots appear to meet the minimum lot size, width, and depth standards of the R-6 zone. Detailed information for lots size would be required at Short Plat submittal to show compliance with lot width, depth, and size requirements. Building Standards – The R-6 standards allow a maximum building coverage of 40% of the lot area. The maximum impervious coverage in the R-6 zone is 55%. Building height is restricted to 30 feet. Detached accessory structures must remain below a height of 15 feet. The gross floor area must be less than that of the primary structure. Accessory structures are also included in building lot coverage calculations. The proposal’s compliance with the building standards would be verified at the time of building permit review for the new residences to be located on all lots. Setbacks – Setbacks are the minimum required distance between the building footprint and the property line. The required setbacks for the R-6 zone are: Front yard: 25 feet for the primary structure; Rear yard: 25 feet; Side yards: combined 15 feet with not less than 5 feet on either side; and Side yards along streets: 25 feet. Setbacks for all buildings would be verified at the time of building permit review. Building Design Standards – The proposed structure would be subject to the Residential Design Standards outlined in RMC 4-2-115. Compliance with the residential design standards would be verified at the time of building permit review. Access/Parking: Access to Lot 1 is proposed via an extension of Redmond Pl NE, a private access road/shared driveway which serves Lots 1-4 of the original Dalpay Short Plat. Proposed Lots 2-4 would be served via an extension of an access easement off of the Redmond Ct NE cul-de-sac of from the neighboring plat to the west (Veldyke II Short Plat, LUA09-058). Shared driveways may be allowed for access to four (4) or fewer residential lots, provided the following criteria found in RMC 4-6-060J is met: a. At least one of the four (4) lots abuts a public right-of-way with at least fifty (50) linear feet of property; and b. The subject lots are not created by a subdivision of ten (10) or more lots; and c. A public street is not anticipated by the City of Renton to be necessary for existing or future traffic and/or pedestrian circulation through the short subdivision or to serve adjacent property; and d. The shared driveway would not adversely affect future circulation to neighboring properties; and e. The shared driveway is no more than two hundred feet (200') in length; and f. The shared driveway poses no safety risk and provides sufficient access for emergency vehicles and personnel. The proposal would exceed the number of lots allowed to gain access to both proposed shared driveways. Additionally, it is not clear that the proposal would meet the criteria found in RMC 4-6-060J (specifically criterion ‘a’, ‘e’, and ‘f’). The applicant would be required to eliminate Lot 1 and two of the three lots located in the southern portion of the site in order to comply with RMC 4-6-060. H:\CED\Planning\Current Planning\PREAPPS\2015 Preapps\15-000551 Alternatively, the applicant may request a street modification in order to allow more than 4 lots to access off of a shared driveway. In order to determine support for such a request staff would consider heavily fire department and public comments. Each lot is required to accommodate off street parking for a minimum of two vehicles. Driveways: The maximum driveway slopes cannot exceed 15%, provided that driveways exceeding 8% are to provide slotted drains at the lower end of the driveway. If the grade exceeds 15%, a variance is required. The maximum width of single loaded garage driveways shall not exceed 9 feet and double loaded garage driveways shall not exceed 16 feet. The proposal includes the use of a pipestem lot (Lot #3). Pipestems lots may be permitted for new plats to achieve the minimum density within the R-6 zone when there is no other feasible alternative to achieve minimum density. The proposal would be required to be revised to eliminate the proposed pipestem lot. Landscaping – Except for critical areas, all portions of the development area not covered by structures, required parking, access, circulation or service areas, must be landscaped with drought-resistant vegetative cover. The minimum on-site landscape width required along street frontages is 10 feet. Such landscaping shall include a mixture of trees, shrubs, and groundcover as approved by the Department of Community and Economic Development. A conceptual landscape plan must be provided with the formal land use application as prepared by a registered Landscape Architect, a certified nurseryman or other certified professional. The plan shall include, but is not limited to, the minimum 10-foot on-site landscaping strip and street trees within the planting strip of each lot. Fences/Walls: If the applicant intends to install any fences or retaining walls as part of this project, the location must be designated on the landscape plan or grading plan. A fence and/or wall detail should also be included on the plan. A fence taller than 6 feet shall require a building permit or an explicit exemption from the Building Official. A retaining wall that is 4 feet or taller, as measured by the vertical distance from the bottom of the footing to the finish grade at the top of the wall requires a building permit. A fence shall not be constructed on top of a retaining wall unless the total combined height of the retaining wall and the fence does not exceed the allowed height of a standalone fence. For more information about fences and retaining walls refer to RMC 4-4-040. Significant Tree Retention: A Tree Retention / Land Clearing (Tree Inventory) Plan along with a tree retention worksheet shall be provided with the formal land use application. Each residential lot to be created by subdivision shall have retained, or newly planted, trees that satisfy the lot’s minimum tree density requirement. The tree retention plan must show preservation of at least thirty percent (30%) of significant trees per RMC 4-4-130H.1.a.i, and indicate how proposed building footprints would be sited to accommodate preservation of significant trees that would be retained. The Administrator may authorize the planting of replacement trees on the site if it can be demonstrated to the Administrator’s satisfaction that an insufficient number of trees can be retained. Please note until formal application is made the City is unable to determine the extent of required tree retention. The applicant will be required to demonstrate all measures to retain trees on site have been exhausted. In addition to retaining 30% of existing significant trees, each new lot would be required to provide a minimum tree density of 2 trees per 5,000 square feet (or the gross equivalent of caliper inches provided by one or more trees) of lot area onsite. Protected trees may contribute to each residential lot’s required minimum tree density, but any trees that are in excess of an individual lot’s minimum tree density shall not contribute to the total number of trees that are required to be retained for the Land Development Permit. Protected trees that do not contribute to a lot’s required minimum tree density shall be held in perpetuity within a tree protection tract. Significant trees shall be retained in the following priority order: H:\CED\Planning\Current Planning\PREAPPS\2015 Preapps\15-000551 Priority One: Landmark trees; significant trees that form a continuous canopy; significant trees on slopes greater than 20%; significant trees adjacent to critical areas and their associated buffers; and significant trees over 60’ in height or greater than 18” caliper. Priority Two: Healthy tree groupings whose associated undergrowth can be preserved; other significant native evergreen or deciduous trees; and other significant non-native trees. Priority Three: Alders and cottonwoods shall be retained when all other trees have been evaluated for retention and are not able to be retained, unless the alders and/ or cottonwoods are used as part of an approved enhancement project within a critical area or its buffer. The Administrator may require an independent review of any land use application that involves tree removal and land clearing at the City's discretion. A formal tree retention plan and arborist report would be reviewed at the time of Preliminary Plat application. Critical Areas: Critical Areas: The site appears to contain a stream. A stream report delineating and classifying the stream is required to be submitted with the formal land use application. All critical areas and buffers are required to be placed in a Native Growth Protection Easement (NGPE). Additionally, the site contains critical and sensitive slopes. If the subject property has an average slope of 20% or any street within the subdivision has grades greater than 15% at any point the proposal would be considered a hillside subdivision. Information concerning the soils, geology, drainage patterns, and vegetation shall be presented in order to evaluate the drainage, erosion control and slope stability for site development of the proposed plat. The applicant must demonstrate that the development of the hillside subdivision will not result in soil erosion and sedimentation, landslide, slippage, excess surface water runoff, increased costs of building and maintaining roads and public facilities and increased need for emergency relief and rescue operations. Detailed plans for any proposed cut and fill operations shall be submitted. These plans shall include the angle of slope, contours, compaction, and retaining walls. Streets may only have a grade exceeding 15% if approved by the Department and the Fire Department. Street widths may be less than those required in the street standards for streets with grades steeper than 15% if parking prohibition on one or both sides of the street is approved by the Administrator. Lots may be required to be larger than minimum lot sizes required by the Zoning Code. Generally, lots in steeper areas of the subdivision should be larger than those in less steep areas of the subdivision. Any clearing or grading shall be accompanied by erosion control measures as deemed necessary by the Department. Environmental Review: Environmental (SEPA) Review is required for projects nine lots or greater, or on sites that contain critical areas. Therefore SEPA would be required for the project. Permit Requirements: The proposed subdivision would require Short Plat Approval, Environmental (SEPA) Review, and a Street Modification. All land use permits would be processed within an estimated time frame of 6-8 weeks. The Short Plat Review application fee is $1,400. The application fee for SEPA Review (Environmental Checklist) is $1,000. All modifications are $150 each. If considered a Hillside Subdivision the proposal would be subject to HEX approval and would be processed concurrently with the other application but would extend the processing time frame to 8-12 weeks. A 3% technology fee would also be assessed at the time of land use application. Detailed information regarding the land use application submittal is provided in the attached handouts. The applicant will be required to install a public information sign on the property. Detailed information regarding the land use application submittal requirements is provided in the attached handouts. Once Preliminary Short Plat approval is obtained, the applicant must complete the required improvements and dedications, as well as satisfy any conditions of the preliminary approval before submitting for Final Short Plat review. Once final approval is received, the plat may be recorded. New lots may only be sold after the plat has been recorded. H:\CED\Planning\Current Planning\PREAPPS\2015 Preapps\15-000551 Fees: In addition to the applicable building and construction fees, the following impact fees would be required prior to the building permit issuance. Fees will be changing January 1, 2016:  A Transportation Impact Fee based on $2,214.44 per each new single family residence;  A Parks Impact Fee based on $1,441.29 per each new single family residence;  A Fire Impact fee of $495.10 per each new single family residence; and  Renton School District Impact Fee is $5,541.00 per each new single family residence. A handout listing Renton’s development-related fees is available on the City of Renton website for your review. Expiration: Upon approval, the short plat is valid for two years with a possible one year extension.