Loading...
HomeMy WebLinkAboutR-387507i NW 1/ SEC 9, T 23 N, R 5 E, W.M. LEGEND m INLET PROTECTION �/ j�/ REMOVE SIDEWALK, DRIVEWAY, CURB & GUTTER HIGH VISIBILTY FENCE (HVF) SILT FENCE ,' , , ,' , CLEARING AND GRUBBING ---------------------- SAWCUT REMOVALS BY OTHERS PIPE REMOVAL REMOVE EXISTING PAVEMENT PLANING BITUMINOUS PAVEMENT (2") / RNER p�ZGH / "NED ... O - 3 j O 4 R/W 6 6 moo^ 6 5 2 13 + + + + v + 9N 16 \ t++t + ++ t ++ + + NE 1OTH S7 4 J 6 R/W MATCH LINE, SEE WG S GENERAL NOTES: 1. APPROXIMATE CLEARING AND GRUBBING LIMITS ARE SHOWN ON THE PLAN. ACTUAL CLEARING AND GRUBBING LIMITS SHALL BE STAKED BY THE CONTRACTOR AND APPROVED BY THE ENGINEER. TREES WITHIN THE CLEARING AND GRUBBING LIMITS SHALL BE PROTECTED OR REMOVED AS SHOWN ON THE PLANS AFTER APPROVAL BY THE ENGINEER. TREE REMOVAL IS COVERED UNDER THE BID ITEM CLEARING AND GRUBBING. 2. TREES AND THEIR ROOT STRUCTURES SHALL BE REMOVED IN A MANNER THAT IS NOT DESTRUCTIVE TO THE TREES THAT ARE TO REMAIN. 3. STORM DRAIN INLET PROTECTION SHALL BE INSTALLED IN ALL NEW CATCH BASINS AT THE TIME OF INSTALLATION AND IN ALL EXISTING CATCH BASINS BEFORE COMMENCING WORK PER THESE PLANS. SEE SECTION 8-01.3(15) OF THE SPECIAL PROVISIONS. 4. THE CONTRACTOR SHALL KEEP A MINIMUM 5 FOOT WIDE ACCESSIBLE PEDESTRIAN PATHWAY AT ALL TIMES, OR AS DIRECTED BY THE ENGINEER. DESOF of CALL 2 BUSINESS DAYS BEFORE YOU DIG Perteet _ - 1 800 4 2 4- 5 5 5 5 206-436-0515 1 1-800-615-990 \ 0&149442 a UTILITIES UNDERGROUND LOCATION CENTER 505 5th Avenue S, Suite 300 �Fss/ONqL E�t21t4 Seattle, Washington 98104 2 No. REVISION 5 KEY MAP 2 15 CONSTRUCTION NOTES: i 23 O1 PROTECT EXISTING CURB AND GUTTER (OR CURB). A � 4 INSTALL STORM DRAIN INLET PROTECTION PER WSDOT a (� O STD PLAN 1-40.20-00. r- OINSTALL HIGH VISIBILITY FENCE PER WSDOT STD PLAN -10.10-01. I R/W O O4 REMOVE EXISTING CURB AND GUTTER (OR CURB). REMOVE EXISTING UTILITY POLE (BY PSE). 'Vj 14 O6 REMOVE EXISTING SIGN AND POST. O7 REMOVE EXISTING ELECTRICAL VAULT. / of \ O8 REMOVE EXISTING TREE, SEE SECTION 2-01 OF THE SPECIAL AINT J PROVISIONS. O9 PROTECT EXISTING MONUMENT. ^�'7� , v 10 PROTECT EXISTING CABINET/PEDESTAL. iQ 11 PROTECT AND MAINTAIN EXISTING LUMINAIRE. co 12 PROTECT EXISTING FIRE HYDRANT. 13 PROTECT EXISTING DRAINAGE STRUCTURE. 14 REMOVE EXISTING DRAINAGE PIPE. 15 REMOVE EXISTING DRAINAGE STRUCTURE. !� REMOVE EXISTING HYDRANT ASSEMBLY AND SALVAGE TO CITY RECORDD RAW I N G 17 REMOVE EXISTING SEWER PIPE 5. SEE ILLUMINATION PLANS FOR ALL LUMINAIRES AND PROTECTION OF EXISTING FACILITIES. 6. SAWCUT LINES FOR UNDER GROUND UTILITIES ARE NOT SHOWN. 7. REMOVE EXISTING IRRIGATION HEADS, VALVES, AND ALL OTHER RELATED IRRIGATION EQUIPMENT AS NECESSARY FOR CONSTRUCTION WORK. CAP EXISTING IRRIGATION LINES AT RIGHT-OF-WAY LINE. 8. ALL EXISTING RAISED PAVEMENT MARKERS, PAINTED LINES, AND PAVING MARKING SYMBOLS IN CONFLICT WITH THE CHANNELIZATION AND SIGNING PLAN SHALL BE REMOVED. 9. EXISTING PIPES SHOWN AS TO BE REMOVED ARE TO BE ABANDONED IN PLACE OR REMOVED AS NEEDED IF IN CONFLICT WITH NEW UTILITIES. REMOVAL OF EXISTING PIPES IS INCIDENTAL TO OTHER BID ITEMS. EXISTING DRAINAGE, WATER, AND SANITARY SEWER PIPES LESS THAN 8-INCHES IN DIAMETER SHALL BE REMOVED AS NECESSARY TO CONSTRUCT PROPOSED IMPROVEMENTS. BUSBY J. BEAN TID 1 3 17 DID �E_ - NmD. DEKOEKKOEK BY DATE APPR "PP-, DE BOLDT THIS RECORD DRAWING WAS PREPARED USING INFORMATION PROVIDED TO CONSULTANT AND 18 REMOVE EXISTING SEWER MANHOLE. CONTAINS ONLY THE LEVEL OF DETAIL AS PROVIDED. THE INFORMATION WAS NOT INDEPENDENTLY FIELD 19 REMOVE EXISTING WATER MAIN. VERIFIED. THE CONSULTANT DOES NOT WARRANT OR GUARANTEE THE ACCURACY OR COMPLETENESS OF THE 20 PLUG AND ABANDON EXISTING PIPE. INFORMATION SHOWN. 21 INSTALL SILT FENCE PER WSDOT STD PLAN 1-30.15-02. ABANDON EXISTING UTILITY STRUCTURE PER CITY OF RENTON 22 STD PLAN 400.5. 23 REMOVE EXISTING ROCKERY. REMOVE AND REINSTALL EXISTING LUMINAIRE POLE PER 24 ILLUMINATION PLANS. USE EXISTING STORMWATER SYSTEM OR CONSTRUCT PROPOSED 25 CONNECTION TO SUNSET BOULEVARD SYSTEM PER DRAINAGE PLANS FOR DISCHARGE OF STORMWATER RUNOFF DURING CONSTRUCTION. 26 PROTECT EXISTING GAS MAIN (2 7 INSTALL TEMP POLE (BY COMCAST/CLINK) SCALE Q 28 20 0 20 40 29 REMOVE EXISTING MAILBOX CLUSTER FEET 30 REMOVE EXISTING LUMINAIRE 1 "=20' RaoM w�3ossn �� DATUM ,F CITY OF RENTON Planning/Building/Public Works Dept. CITY OF RENTON SUNSET LANE NE IMPROVEMENTS SITE PREPARATION PLAN 4/2016 SP4 7 9