HomeMy WebLinkAboutR-387507i
NW 1/ SEC 9, T 23 N, R 5 E, W.M.
LEGEND
m INLET PROTECTION �/ j�/ REMOVE SIDEWALK, DRIVEWAY, CURB & GUTTER
HIGH VISIBILTY FENCE (HVF)
SILT FENCE ,' , , ,' , CLEARING AND GRUBBING
---------------------- SAWCUT
REMOVALS BY OTHERS
PIPE REMOVAL
REMOVE EXISTING PAVEMENT PLANING BITUMINOUS PAVEMENT (2") /
RNER p�ZGH /
"NED
... O - 3
j
O 4 R/W 6
6 moo^ 6 5
2 13 + + + + v
+ 9N
16
\ t++t + ++ t ++ + +
NE 1OTH S7
4
J
6
R/W MATCH LINE, SEE WG S
GENERAL NOTES:
1. APPROXIMATE CLEARING AND GRUBBING LIMITS ARE SHOWN ON THE PLAN.
ACTUAL CLEARING AND GRUBBING LIMITS SHALL BE STAKED BY THE
CONTRACTOR AND APPROVED BY THE ENGINEER. TREES WITHIN THE
CLEARING AND GRUBBING LIMITS SHALL BE PROTECTED OR REMOVED AS
SHOWN ON THE PLANS AFTER APPROVAL BY THE ENGINEER. TREE
REMOVAL IS COVERED UNDER THE BID ITEM CLEARING AND GRUBBING.
2. TREES AND THEIR ROOT STRUCTURES SHALL BE REMOVED IN A MANNER
THAT IS NOT DESTRUCTIVE TO THE TREES THAT ARE TO REMAIN.
3. STORM DRAIN INLET PROTECTION SHALL BE INSTALLED IN ALL NEW CATCH
BASINS AT THE TIME OF INSTALLATION AND IN ALL EXISTING CATCH BASINS
BEFORE COMMENCING WORK PER THESE PLANS. SEE SECTION 8-01.3(15)
OF THE SPECIAL PROVISIONS.
4. THE CONTRACTOR SHALL KEEP A MINIMUM 5 FOOT WIDE ACCESSIBLE
PEDESTRIAN PATHWAY AT ALL TIMES, OR AS DIRECTED BY THE ENGINEER.
DESOF
of
CALL 2 BUSINESS DAYS BEFORE YOU DIG Perteet _
-
1 800 4 2 4- 5 5 5 5 206-436-0515 1 1-800-615-990 \ 0&149442 a
UTILITIES UNDERGROUND LOCATION CENTER 505 5th Avenue S, Suite 300 �Fss/ONqL E�t21t4
Seattle, Washington 98104 2 No. REVISION
5
KEY MAP
2 15
CONSTRUCTION NOTES:
i 23
O1
PROTECT EXISTING CURB AND GUTTER (OR CURB).
A �
4
INSTALL STORM DRAIN INLET PROTECTION PER WSDOT
a (�
O
STD PLAN 1-40.20-00.
r-
OINSTALL
HIGH VISIBILITY FENCE PER WSDOT STD PLAN
-10.10-01.
I R/W O
O4
REMOVE EXISTING CURB AND GUTTER (OR CURB).
REMOVE EXISTING UTILITY POLE (BY PSE).
'Vj 14
O6
REMOVE EXISTING SIGN AND POST.
O7
REMOVE EXISTING ELECTRICAL VAULT.
/
of \
O8
REMOVE EXISTING TREE, SEE SECTION 2-01 OF THE SPECIAL
AINT J
PROVISIONS.
O9
PROTECT EXISTING MONUMENT.
^�'7�
, v
10
PROTECT EXISTING CABINET/PEDESTAL.
iQ
11
PROTECT AND MAINTAIN EXISTING LUMINAIRE.
co
12
PROTECT EXISTING FIRE HYDRANT.
13
PROTECT EXISTING DRAINAGE STRUCTURE.
14
REMOVE EXISTING DRAINAGE PIPE.
15
REMOVE EXISTING DRAINAGE STRUCTURE.
!�
REMOVE EXISTING HYDRANT ASSEMBLY AND SALVAGE TO CITY
RECORDD RAW I N G
17
REMOVE EXISTING SEWER PIPE
5. SEE ILLUMINATION PLANS FOR ALL LUMINAIRES AND PROTECTION OF
EXISTING FACILITIES.
6. SAWCUT LINES FOR UNDER GROUND UTILITIES ARE NOT SHOWN.
7. REMOVE EXISTING IRRIGATION HEADS, VALVES, AND ALL OTHER RELATED
IRRIGATION EQUIPMENT AS NECESSARY FOR CONSTRUCTION WORK. CAP
EXISTING IRRIGATION LINES AT RIGHT-OF-WAY LINE.
8. ALL EXISTING RAISED PAVEMENT MARKERS, PAINTED LINES, AND PAVING
MARKING SYMBOLS IN CONFLICT WITH THE CHANNELIZATION AND SIGNING
PLAN SHALL BE REMOVED.
9. EXISTING PIPES SHOWN AS TO BE REMOVED ARE TO BE ABANDONED IN
PLACE OR REMOVED AS NEEDED IF IN CONFLICT WITH NEW UTILITIES.
REMOVAL OF EXISTING PIPES IS INCIDENTAL TO OTHER BID ITEMS. EXISTING
DRAINAGE, WATER, AND SANITARY SEWER PIPES LESS THAN 8-INCHES IN
DIAMETER SHALL BE REMOVED AS NECESSARY TO CONSTRUCT PROPOSED
IMPROVEMENTS.
BUSBY
J. BEAN
TID 1 3 17 DID �E_ -
NmD. DEKOEKKOEK
BY DATE APPR "PP-, DE BOLDT
THIS RECORD DRAWING WAS PREPARED USING
INFORMATION PROVIDED TO CONSULTANT AND
18
REMOVE EXISTING SEWER MANHOLE.
CONTAINS ONLY THE LEVEL OF DETAIL AS PROVIDED.
THE INFORMATION WAS NOT INDEPENDENTLY FIELD
19
REMOVE EXISTING WATER MAIN.
VERIFIED. THE CONSULTANT DOES NOT WARRANT OR
GUARANTEE THE ACCURACY OR COMPLETENESS OF THE
20
PLUG AND ABANDON EXISTING PIPE.
INFORMATION SHOWN.
21
INSTALL SILT FENCE PER WSDOT STD PLAN 1-30.15-02.
ABANDON EXISTING UTILITY STRUCTURE PER CITY OF RENTON
22
STD PLAN 400.5.
23
REMOVE EXISTING ROCKERY.
REMOVE AND REINSTALL EXISTING LUMINAIRE POLE PER
24
ILLUMINATION PLANS.
USE EXISTING STORMWATER SYSTEM OR CONSTRUCT PROPOSED
25
CONNECTION TO SUNSET BOULEVARD SYSTEM PER DRAINAGE
PLANS FOR DISCHARGE OF STORMWATER RUNOFF DURING
CONSTRUCTION.
26
PROTECT EXISTING GAS MAIN
(2 7
INSTALL TEMP POLE (BY COMCAST/CLINK)
SCALE
Q
28
20 0 20 40
29
REMOVE EXISTING MAILBOX CLUSTER
FEET
30
REMOVE EXISTING LUMINAIRE
1 "=20' RaoM w�3ossn
�� DATUM
,F CITY OF
RENTON
Planning/Building/Public Works Dept.
CITY OF RENTON
SUNSET LANE NE IMPROVEMENTS
SITE PREPARATION PLAN
4/2016
SP4
7 9