Loading...
HomeMy WebLinkAboutR-387522I IADEGR BREAK SEE DWG PL1 FOR FOR(TYP) CURB BULB DATA \ 17 8 + + + + + 21 + + e.. 18 e aT v . a ACONSTR CTED �• 1 19 0 ` `20 a„.:.e.a.;.e:=.•,.,•._,< + + + + + + + 2% + + + + + + + + 12 + + + + + + 1 �4 + + + + + L .RAMP OPENING AT CURB AS 25+22.62 CONSTRUCTED L E � 1 A 1 4 A F STA 1 + 1 1 ^T .END TRANSITION. T( CURB AND GUTTER CURB AND GUTTER BY OTHERS STA 10+18.96 (15. END TRANSITION TO CURB SECTION BEGIN TRANSITION TO CURB SECTION SUNSET LANE NE & NE 10TH ST 10" CEMENT CONCRETE 6" HMA CL 1/2" PAVEMENT WITH 2'x2' PG 64-22 SAWCUT SCORING PATTERN 77Ty-4 xk .. .. 's a e 4" CSTC SECTION A -A CALL 2 BUSINESS DAYS BEFORE YOU DIG Per'tee't 1 800 4 2 4- 5 5 5 5 206-436-0515 1 1-800-615-94 UTILITIES UNDERGROUND LOCATION CENTER 505 5th Avenue S, Suite 300 Seattle, Washington 98104 /.\ o D E S Off. F \ 49442 p �" �F�STNNAL EENG\�2112119 No. 4" CSTC SIDEWALK POINT TABLE POINT STATION (OFFSET) ELEVATION 1 25+69.64 (16.00' RT) 343.68 2 25+63.96 (16.00' RT) 343.48 3 25+53.96 (16.00' RT) 343.14 6 10+13.36 (19.47' LT) 342.63 7 10+18.71 (14.02' LT) 341.95 12 10+22.23 (12.12' LT) 341.88 13 10+28.22 (10.84' LT) 342.21 14 10+29.27 (10.69' LT) 342.17 15 25+53.96 (29.45' RT) 343.01 16 25+63.96 (29.50' RT) 343.48 17 25+69.64 (29.50' RT) 343.75 18 10+40.00 (42.50' LT) 342.97 19 10+40.00 (32.50' LT) 342.82 20 10+53.90 (32.50' LT) 342.17 21 10+69.50 (42.50' LT) 341.58 22 10+69.50 (32.50' LT) 341.43 *STA/OFF INFORMATION FOR POINTS ADJACENT TO THE CURB LINE, EXCEPT POINTS 7 AND 12, IS MEASURED TO THE TOP -BACK OF CURB CONCRETE CROSSWALK DATA POINT STATION (OFFSET) ELEVATION A 10+14.50 (17.45' LT) 342.05 B 10+14.50 (0.00') 341.94 C 10+14.50 (20.97' RT) 341.47 D 10+24.50 (11.25' LT) 341.84 E 10+24.50 (0.00') 341.84 F 10+24.50 (12.40' RT) 341.72 * FLOW LINE ELEVATION IF AT CURB CR1-CURB RETURN DATA HORIZONTAL VERTICAL PC = STA 25+56.45 (7.50' RT) FLOW LINE = 89'41'09" 343.0 PC= 342.31. 122- R = 25.00' �4 L = 39.13' 1/2= 342.04 T = 24.86' 3/4= 341.87 PT = STA 10+32.21 (10.00' LT) PT = 341.56 CENTER RADIUS - STA 25+56.45 (32.50' RT) * SEE POINTS "A" AND "D" IN THE CONCRETE CROSSWALK DATA TABLE FOR ADDITIONAL CURB RETURN FLOW LINE ELEVATIONS. DID 7/5/1 DID Esc"E J. HUYLAR DID 7/5/1 DID . J. BEAN DID 7/5/11 DID CH'".-. DEKOEKKOEK REVISION BY DATE APPR "PA P DE BOLDT CR2-CURB RETURN DATA HORIZONTAL VERTICAL PC = STA 24+86.43 (10.00' RT) FLOW LINE ELEVATIONS = 90'18'51" PC= 341.19 R = 25.00' 1/4= 341.38 L = 39.41' 1/2= 341.56 T = 25.14' 3/4= 341.75 PT = STA 10+35.19 (10.00' RT) I PT = 341.93 CENTER RADIUS - STA 10+35.19 (35.00' RT) �� DATUM • • 10 20 FEET ,F CITY OF RENTON Planning/Building/Public Works Dept CONSTRUCTION NOTES OCONSTRUCT CEMENT CONCRETE TRAFFIC CURB AND GUTTER PER WSDOT STD PLAN F-10.12-03. OCONSTRUCT CEMENT CONCRETE DEPRESSED CURB SECTION PER WSDOT STD PLAN F-10.12-03. OCONSTRUCT THICKENED 3" CEMENT CONCRETE TRAFFIC CURB AND GUTTER PER DETAIL ON DWG MD1. OCONSTRUCT THICKENED CEMENT CONCRETE DEPRESSED CURB SECTION PER DETAIL ON DWG MD1. OCONSTRUCT MONOLITHIC CEMENT CONCRETE CURB, GUTTER, AND SIDEWALK PER DETAIL ON DWG MD1. OCONSTRUCT CEMENT CONCRETE VALLEY GUTTER PER DETAIL ON DWG MD1. (DCONSTRUCT CEMENT CONCRETE PEDESTRIAN CURB PER CITY OF RENTON STD PLAN 101. OINSTALL EXTRUDED CURB TYPE 6 PER WSDOT STD PLAN F-10.42-00. OINSTALL PRECAST SLOPED MOUNTABLE CURB PER WSDOT STD PLAN F-10.62-02. CONSTRUCT CEMENT CONCRETE DRIVEWAY ENTRANCE TYPE C2B 10 PER CITY OF RENTON STD PLAN 104.4 OVER 4" CSTC (SEE GENERAL NOTE 1). 11 CONSTRUCT CURB RAMP TYPE PERPENDICULAR PER DETAIL ON DWG MD2. 12 INSTALL DETECTABLE WARNING SURFACE PER WSDOT STD PLAN F-45.10-01. 13 CONSTRUCT TRANSITION RAMP PER DETAIL ON DWG MD1. CONSTRUCT ASPHALT DRIVEWAY WITH 4" HMA FOR APPROACH 14 CL 1/2" PG 64-22 OVER 4" CSTC. 15 CONSTRUCT ASPHALT SIDEWALK WITH 3" HMA CL 1/2" PG 64-22 OVER 4" CSTC. 16 CONSTRUCT DECORATIVE EXPOSED AGGREGATE TREATMENT PER DETAIL ON DWG MD8. 17 INSTALL MONUMENT CASE AND COVER (SEE DWG AL7). 18 ADJUST EXISTING MONUMENT CASE AND COVER. 19 ADJUST EXISTING CB. 20 ADJUST EXISTING MH. 21 ADJUST EXISTING VALVE BOX. 22 SLOPE OF PARKING LANE VARIES (SEE CURB BULB DATA). GENERAL NOTES 1. SIDEWALK GRADE SHALL BE MAINTAINED THROUGH ALL DRIVEWAYS; DO NOT DEPRESS SIDEWALK. STATION/OFFSET PROVIDED TO CENTER OF DRIVEWAYS AT FACE OF CURB. SIDEWALK THICKNESS SHALL MATCH DRIVEWAY THICKNESS IN DRIVEWAY AREA. LEGEND 2" HMA CL 1/2" PG 64-22 OVERLAY (FINAL LIFT OF ADJACENT FULL DEPTH PAVEMENT SHALL BE PLACED SIMULTANEOUSLY WITH OVERLAY) 6" HMA CL 1/2" PG 64-22 OVER 4" CSTC 9" HMA CL 1/2" PG 64-22 OVER 4" CSTC a SIDEWALK PER CITY OF RENTON STD PLAN 102 d WITH 2'x2' SAWCUT SCORING OVER 4" CSTC DECORATIVE EXPOSED AGGREGATE TREATMENT PER DETAIL ON DWG MD8 LANDSCAPE (SEE PP DRAWINGS) L LONGITUDINAL JOINT WITH TIE BARS PER DETAIL ON DWG MD1 T TRANSVERSE JOINT WITH DOWELS PER DETAIL ON DWG MD1 RECORD DRAWING THIS RECORD DRAWING WAS PREPARED USING INFORMATION PROVIDED TO CONSULTANT AND CONTAINS ONLY THE LEVEL OF DETAIL AS PROVIDED. THE INFORMATION WAS NOT INDEPENDENTLY FIELD VERIFIED. THE CONSULTANT DOES NOT WARRANT OR GUARANTEE THE ACCURACY OR COMPLETENESS OF THE INFORMATION SHOWN. CITY OF RENTON �.E 4/2016 SUNSET LANE NE IMPROVEMENTS MD3 MISCELLANEOUS DETAILS 22 ° s