Loading...
HomeMy WebLinkAboutR-387534NW 1/ SEC 9, T 23 N, R 5 E, W.M. w z z U w W z a a __J I— w (n z (n CB jj10, TYPE 2-48", W SOLID LOCKING LID STA 17+71.16 (13.5' s CO 8 8" CLEANOUT STA 17+70.53 (34.1' LT) GENERAL NOTES 1. ALL STORM SEWER PIPE SHALL BE SCHEDULE A SMOOTH INTERIOR WALL HIGH—PERFORMANCE POLYPROPYLENE STORM SEWER PIPE, UNLESS OTHERWISE NOTED. 2. ALL CATCH BASINS AND INLETS SHALL HAVE A VANED GRATE PER CITY OF RENTON STD. PLAN 204.20, UNLESS OTHERWISE NOTED. 3. LOCATIONS OF UNDERGROUND UTILITIES SHOWN ARE APPROXIMATE. 4.THE CONTRACTOR SHALL POTHOLE ALL UTILITY CROSSINGS PRIOR TO STARTING CONSTRUCTION OF THE PIPE RUN. 5. FOR CATCH BASIN RIM ELEVATION AND PIPE INVERTS SEE SHEETS DP7—DP5. 6. ALL CATCH BASINS AND BIORETENTION FILTRATION UNITS ARE CALLED OUT TO THE CENTER OF STRUCTURE. SEE SHEET DD1 FOR CATCH BASIN TYPE 2-48" ROTATION AND GRATE PLACEMENT. 7.ROTATE TYPE 1 CATCH BASINS SO THAT THE LONGER SIDE IS PARALLEL TO PROPOSED CURB. ROTATE TYPE 2 CATCH BASINS WITH SOLID LIDS TO KEEP LIDS OUT OF WHEEL PATH. 8. ALL CATCH BASIN RIMS ALONG GUTTER FLOWLINES ARE SET 0.08' LOWER THAN THEORETICAL FLOW LINE ELEVATION. CALL 2 BUSINESS DAYS BEFORE YOU DIG Per'tee't 1 800 4 2 4— 5 5 5 5 206-436-0515 1 1-800-615-91 UTILITIES UNDERGROUND LOCATION CENTER 505 5th Avenue S, Suite 300 Seattle, Washington 98104 DEKG 0 om O 49442 O EENG�21t21t9 CONSTRUCTION NOTES O CONNECT NEW PIPE TO EXISTING DRAINAGE STRUCTURE O CONNECT EXISTING PIPE TO NEW DRAINAGE STRUCTURE ONOT USED O4 NOT USED OS NOT USED OSEE SHEET DD1 FOR BIORETENTION FILTRATION UNIT OUTLET CONNECTION DETAIL. O7 INSTALL SOLID LOCKING LID PER CITY OF RENTON STD. PLAN 204.10 AND 204.50. O8 RECTANGULAR BI—DIRECTIONAL VANED GRATE PER CITY OF RENTON STD. PLAN 204.30 WITH OPEN CURB FACE FRAME PER CITY OF RENTON STD PLAN 203.00. O PROTECT EXISTING DRAINAGE STRUCTURE. N0. I REVISION 8.3 LF 18" SO ® 1.009 GE=338.58 IE=331.35 12.0 LF 8" SO 0 1.00% MPS SEA LEGEND SD STORM DRAIN PIPE SS SANITARY SEWER PIPE W WATER LINE PIPE SS SANITARY SEWER PIPE (EXISTING) SD STORM DRAIN PIPE (EXISTING) W WATER LINE PIPE (EXISTING) 0 CATCH BASIN TYPE 1 0 CATCH BASIN TYPE 2 (GRATE) M CATCH BASIN TYPE 2 (SOLID LID) SANITARY SEWER MANHOLE BIORETENTION FILTRATION UNIT Ak FIRE HYDRANT ������������������ PIPE REMOVAL O CONSTRUCTION NOTE mmxeoM. JAIN J. BEAN nmxmP DE BOLDT BY DATE APPR PA D. DEKOEKKDEK CITY OF RENTON �� DATUM x.u-�maax��r Planning/Building/Public Works Dept. KEY MAP RECORD DRAWING THIS RECORD DRAWING WAS PREPARED USING INFORMATION PROVIDED TO CONSULTANT AND CONTAINS ONLY THE LEVEL OF DETAIL AS PROVIDED. THE INFORMATION WAS NOT INDEPENDENTLY FIELD VERIFIED. THE CONSULTANT DOES NOT WARRANT OR GUARANTEE THE ACCURACY OR COMPLETENESS OF THE INFORMATION SHOWN. SCALE 20 0 20 FEET CITY OF RENTON SUNSET LANE NE IMPROVEMENTS DRAINAGE PLAN �B0/2016 DR3 sxE�. 349