Loading...
HomeMy WebLinkAboutR-387535NW 1/ SEC 9, T 23 N, R 5 E, W.M. STA # 2 3 � /E 1 L 2 Q4 CB #40, TYPE 1 y STA 22+33.00 (43.3' L R/W C EX TYPE 2 STA 24+41.22 (60.6'/LT) CB EX 54, EXIST TYPE 1 7 g 9 13.9 LF 12" SO ® 2.09% STA 22+32.53 (48.3' LT)" �� 13.7 LF 12" SD ® 1.46% V\ 1 CB #41, TYPE 1 ,\\\ �' \ \ CB #4, TYPE 2-48" STA 24+35.23 (48.1' 8 LT) i 5.1 LF EX 12" HDPE 0 3.35% �L� STA 22+65.40 (10.3' LT) \\ \\\ \ �\ 19.4 LF 12" SO ® 6.33% 18.4 LF 12" SD ® 0.99% \\\ I E 0 \3% \ �\ 21.6 LF 12" SO ® 0.53% SCB TA 42, TYSO (48.0' LT) ST # 2 26. EXIST TYPE 1 STA 2+90 63 (20'LFILTRATION UNIT 6 38.7 LF 18" SO ® 2.20% W � 9 STA 22+26.14 (49.1' LT) z \ \ 5 9 7 47.8 LF 12" SD ®0.49% #3, TYPE 2-48" Z LU 52.4 LF 18" SO 0 1.45% W SOLID LOCKING LID Z CB #38, TYPE 1L \ STA 23+29.88 (14.4' LT) JSTA 22+02.26 (49.0' LT) \ R/W / LU i/) \ o SD 7,Zr Z 57.4 LF 18" SD ® 2.00% i � s ss ss , N 5( / W++ ++ Z NE 1jjN 89.4 LF 18" SD ® 0.5 h 'ss -ss-----ss- �w{ 1 - - ss \ jSg 1 7.4 LF 8" CPEP 0 5.0% CB #43, TYPE 2-48" W SOLID LOCKING LID \� 55 ----- du STA 24+16.10 (9.3' LT) i _ ---- W 2.6 LF 2" SD ® 0.69% - R/W \ \ \,, 45.8 LF 18" SO 0 0.50%- / \ CB #52, TYPE 1 ems' 1 \ 8 9 CB #2, TYPE 2-48" Q =� CB 39, TYPE 2-48" c CB #25, TYPE 2-48" 1 �O \ 8 STA 24+61.88 (10.3' LT) W SOLID LOCKING LID STA 22+85.17 (15.5' LT) / STA 22+03.76 (8.4' RT) � / CB #46, TYPE 1- 8 SS - - 19.4 LF 112" SO ® 8.97% / 182.3 LF 18" SD ® \.O6% \ \ \ STA 22+65.54 (9.2' RRT) O _ _ S os 5� o29.3 LF 18" SD ® 8.93% \ I \ o / g0 \ \ \ 8 CB #60, TYPE 1 CB #65, TYPE 1L \ /� \ \ STA 2\ 61.91 (9.2' RT) CA CB r W SOLID LOCKING LID / 30 24.3 LF EX 18" SD ® 1.36% STA 22+33.09 (9.2' RT) \ / 1 GENERAL NOTES 1. ALL STORM SEWER PIPE SHALL BE SCHEDULE A SMOOTH INTERIOR WALL HIGH-PERFORMANCE POLYPROPYLENE STORM SEWER PIPE, UNLESS OTHERWISE NOTED. 2. ALL CATCH BASINS AND INLETS SHALL HAVE A VANED GRATE PER CITY OF RENTON STD. PLAN 204.20, UNLESS OTHERWISE NOTED. 3. LOCATIONS OF UNDERGROUND UTILITIES SHOWN ARE APPROXIMATE. 4.THE CONTRACTOR SHALL POTHOLE ALL UTILITY CROSSINGS PRIOR TO STARTING CONSTRUCTION OF THE PIPE RUN. 5. FOR CATCH BASIN RIM ELEVATION AND PIPE INVERTS SEE SHEETS DP7-DP5. 6. ALL CATCH BASINS AND BIORETENTION FILTRATION UNITS ARE CALLED OUT TO THE CENTER OF STRUCTURE. SEE SHEET DD1 FOR CATCH BASIN TYPE 2-48" ROTATION AND GRATE PLACEMENT. 7.ROTATE TYPE 1 CATCH BASINS SO THAT THE LONGER SIDE IS PARALLEL TO PROPOSED CURB. ROTATE TYPE 2 CATCH BASINS WITH SOLID LIDS TO KEEP LIDS OUT OF WHEEL PATH. 8. ALL CATCH BASIN RIMS ALONG GUTTER FLOWLINES ARE SET 0.08' LOWER THAN THEORETICAL FLOW LINE ELEVATION. CONSTRUCTION NOTES O1 CONNECT NEW PIPE TO EXISTING DRAINAGE STRUCTURE O CONNECT EXISTING PIPE TO NEW DRAINAGE STRUCTURE ONOT USED O4 NOT USED ONOT USED OSEE SHEET DD1 FOR BIORETENTION FILTRATION UNIT OUTLET CONNECTION DETAIL. O7 INSTALL SOLID LOCKING LID PER CITY OF RENTON STD. PLAN 204.10 AND 204.50. OS RECTANGULAR BI-DIRECTIONAL VANED GRATE PER CITY OF RENTON STD. PLAN 204.30 WITH OPEN CURB FACE FRAME PER CITY OF RENTON STD PLAN 203.00. O PROTECT EXISTING DRAINAGE STRUCTURE. CONNECT EXISTING 8" SD Q i o� R/W r O FRENCH DRAIN WITH 4" �i PERFORATED PIPE 3 2 CONNECTED TO CB #41 ,a IV N \ //�:T-441 c/ e/ �V �Q SD STORM DRAIN PIPE SS SANITARY SEWER PIPE W WATER LINE PIPE SS SANITARY SEWER PIPE (EXISTING) SD STORM DRAIN PIPE (EXISTING) W WATER LINE PIPE (EXISTING) 0 CATCH BASIN TYPE 1 0 CATCH BASIN TYPE 2 (GRATE) CATCH BASIN TYPE 2 (SOLID LID) SANITARY SEWER MANHOLE BIORETENTION FILTRATION UNIT FIRE HYDRANT PIPE REMOVAL XO CONSTRUCTION NOTE KEY MAP RECORD DRAWING THIS RECORD DRAWING WAS PREPARED USING INFORMATION PROVIDED TO CONSULTANT AND CONTAINS ONLY THE LEVEL OF DETAIL AS PROVIDED. THE INFORMATION WAS NOT INDEPENDENTLY FIELD VERIFIED. THE CONSULTANT DOES NOT WARRANT OR GUARANTEE THE ACCURACY OR COMPLETENESS OF THE INFORMATION SHOWN. SCALL 20 0 20 40 FEET DEKO AS CALL 2 BUSINESS DAYS BEFORE YOU DIG Perteet _ ��0 5 DID 5 t DID 6� aoM �800 o w (....) CITY OF RENTON 4/2016 z 4 DID 5 1 DID 1"=20' "`""° AR CITY OF � 3 DID 5 t DID xEoM "'" SUNSET LANE NE IMPROVEMENTS 1 800 4 2 4- 5 5 5 5 206-436-0515 1 1-800-615-990 \ P 2 DID 5 1 DID „­ BEAN RENTON orb, RFc9 ��E° �``' 1 LKM IV21116 DID DATUM UTILITIES UNDERGROUND LOCATION CENTER 505 5thAvenue S, Suite 300 ss/pNAL E PgNmP. DE BOLDT �NGLy Planning/Building/Publlo Works Dept. DR4 Seattle, Washington 98104 N0. REVISION BY DATE APPR " o. DEKOEKKOEK DRAINAGE PLAN 35 "9,