HomeMy WebLinkAboutR-387536W w Q z z U w W z a a _J I— w (n z (n Q 0 w LIJ O 04 W Lv z J U Q 1. ALL STORM SEWER PIPE SHALL BE SCHEDULE A SMOOTH INTERIOR WALL HIGH-PERFORMANCE POLYPROPYLENE STORM SEWER PIPE, UNLESS OTHERWISE NOTED. 2. ALL CATCH BASINS AND INLETS SHALL HAVE A VANED GRATE PER CITY OF RENTON STD. PLAN 204.20, UNLESS OTHERWISE NOTED. 3. LOCATIONS OF UNDERGROUND UTILITIES SHOWN ARE APPROXIMATE. 4. THE CONTRACTOR SHALL POTHOLE ALL UTILITY CROSSINGS PRIOR TO STARTING CONSTRUCTION OF THE PIPE RUN. 5. FOR CATCH BASIN RIM ELEVATION AND PIPE INVERTS SEE SHEETS DP7-DP5. 6. ALL CATCH BASINS AND BIORETENTION FILTRATION UNITS ARE CALLED OUT TO THE CENTER OF STRUCTURE. SEE SHEET DD1 FOR CATCH BASIN TYPE 2-48" ROTATION AND GRATE PLACEMENT. 7. ROTATE TYPE 1 CATCH BASINS SO THAT THE LONGER SIDE IS PARALLEL TO PROPOSED CURB. ROTATE TYPE 2 CATCH BASINS WITH SOLID LIDS TO KEEP LIDS OUT OF WHEEL PATH. 8. ALL CATCH BASIN RIMS ALONG GUTTER FLOWLINES ARE SET 0.08' LOWER THAN THEORETICAL FLOW LINE ELEVATION. SD STORM DRAIN PIPE SS SANITARY SEWER PIPE W WATER LINE PIPE SS SANITARY SEWER PIPE (EXISTING) — —SD— STORM DRAIN PIPE (EXISTING) — — W — — WATER LINE PIPE (EXISTING) CATCH BASIN TYPE 1 0 CATCH BASIN TYPE 2 (GRATE) NW 1/ SEC 9, T 23 N, R 5 E, W.M. Z _ rn 1 CB #Fi 5, 4'X4' FILTRATION UNIT 6 STA 50+94.48 (14jRT)' NI2 LF C CB 24, TYPESTA 50+87.01 �1 Ld LLJ w N Lc) — — — N so - G Lli — z CB #22, TYPE 2-48" QU STA 51+09.73 (17.0' LT) 9W0 CPEP ® 5.0% CB #Fi 6, 4'X4' FILTRATION UNIT STA 51+19.12 (22.5' LT) O CONNECT NEW PIPE TO EXISTING DRAINAGE STRUCTURE. O CONNECT EXISTING PIPE TO NEW DRAINAGE STRUCTURE. O3 NOT USED O4 NOT USED O5 NOT USED O6 SEE SHEET DD1 FOR BIORETENTION FILTRATION UNIT OUTLET CONNECTION DETAIL. O7 INSTALL SOLID LOCKING LID PER CITY OF RENTON STD. PLAN 204.10 AND 204.50. O8 RECTANGULAR BI-DIRECTIONAL VANED GRATE PER CITY OF RENTON STD. PLAN 204.30 WITH OPEN CURB FACE FRAME PER CITY OF RENTON STD PLAN 203.00. O PROTECT EXISTING DRAINAGE STRUCTURE. 0 CATCH BASIN TYPE 2 (SOLID LID) SANITARY SEWER MANHOLE BIORETENTION FILTRATION UNIT FIRE HYDRANT PIPE REMOVAL OX CONSTRUCTION NOTE CALL 2 BUSINESS DAYS BEFORE YOU DIG Per'tee't 1 800 4 2 4— 5 5 5 5 206-436-0515 1 1-800-615-91 UTILITIES UNDERGROUND LOCATION CENTER 505 5th Avenue S, Suite 300 Seattle, Washington 98104 0EK0 0 om O 49442 O EENG�21t21t9 22.3 LF 12" SD 0 0.72% I N I 54.2 LF 24" SD ® 0.50% 11 W I� VT - MI HARRINGTON AVE NE I CB #23, TYPE 2-48" T—STA 50+86.80 (10.2' LT) LF 24" SO 0 0.34% / I 65 RECORD DRAWING THIS RECORD DRAWING WAS PREPARED USING INFORMATION PROVIDED TO CONSULTANT AND CONTAINS ONLY THE LEVEL OF DETAIL AS PROVIDED. THE INFORMATION WAS NOT INDEPENDENTLY FIELD VERIFIED. THE CONSULTANT DOES NOT WARRANT OR GUARANTEE THE ACCURACY OR COMPLETENESS OF THE INFORMATION SHOWN. SCALE 20 0 20 40 FEET A CUT AND REMOVE TOP — HALF OF EXISTING PIPE. BOTTOM HALF TO REMAIN AS MANHOLE CHANNEL SLOPE BENCH 1:10 PLAN VIEW NU" SHAPED MANHOLE KNOCKOUT TO - INSTALL MANHOLE OVER EXISTING PIPE. PROVIDE 2" CLEARANCE (MIN) AROUND PIPE AND GROUT. CONCRETE SLAB MAY BE — PRECAST OR CAST IN PLACE #4 0 12" C/C EACH WAY - DO NOT SET OVER EXISTING JOINT 8" PEA GRAVEL BASE UNDISTURBED NATIVE MATERIAL CONCRETE SADDLE MANHOLE DETAIL N.T.S. 48" KEY MAP FLAT TOP PER COR STD. PLAN 201.00 W/ FRAME AND VANED GRATE GRATE IN FLOWLINE PRECAST REINFORCED CONCRETE SECTION CORE DRILL AND LINK SEAL OR KOR-N-SEAL BOOT 24" HOPE PIPE FORM CONCRETE BASE AND CHANNEL IN FIELD —PRECAST SECTION TO BE PLACED OVER MAIN AFTER REINFORCED z z CONCRETE SLAB HAS BEEN POURED AND MUST HAVE MINIMUM 2" EMBEDMENT IN CONCRETE SLAB. N � SECTION A —A 1 =20°""e"" ® CITY OF RENTON 4/2016 rs JaIN ,� CITY OF SUNSET LANE NE IMPROVEMENTS a° 2 DID +o/2e/�e DID """�"� J. BEAN 9 I�NTON . 1 DID z/n/ie MW "__ - DATUM W DR5 "mP DE BOLDT Planning/Building/Public Works Dept. N0. REVISION BY DATE APPR PA o. oEKOEKKOEK x.��maa"=�r DRAINAGE PLAN 36 °`s,