HomeMy WebLinkAboutW-387501w w
Q
z
z
U w
w z
a
a __J
I—
w
(n
z
(n
••
_ I� e
FE
•
frill
8 LF 12" DI I��'�•�.' i••' •�•i'
ff
W
W/THRUST
NW 1/ SEC 9, T 23 N, R 5 E, W.M.
W
.57 21.50' LT
BEND MJxMJ o
BLOCK g
STA 12+21
1-12" END
W/THRUST
R/W
F
— 50 LF 12" Dl-,ss,
� � I
—
BEGIN PROJECT
SS
SS SS !
SS
S-LINE STA 10+00
°
/
32 LF 12" DI
v�{I
O
TSL2+7
R
600' RT5N
R/W
MJ1-0
12 4
4
_....0
W/THRUST BLOCK I
STA 1S
STA 25+02.37 3.55' RT
I
W W 20 LF 12" DI
1
72 LF 12" DI O �I 1-12 22 1 2' BEND MJ_
S m W/THRUST BLOCK
O G
STA 12+21.50
MATCH LINE STA 24+75,
1-12"x12 GATE VI
SEE DWG WP4
GENERAL NOTES
1. THE CONTRACTOR SHALL POTHOLE ALL UTILITY
CROSSINGS PRIOR TO STARTING CONSTRUCTION OF THE
PIPE RUN.
2. ALL MJ FITTINGS AND VALVES SHALL HAVE MEGALUGS
(OR APPROVED EQUAL) RETAINER GLANDS IN ADDITION
TO CONCRETE BLOCKING.
CALL 2 BUSINESS DAYS BEFORE YOU DIG Per'tee't
1 800 4 2 4- 5 5 5 5 206-436-0515 1 1-800-615-91,
UTILITIES UNDERGROUND LOCATION CENTER 505 5th Avenue S, Suite 300
Seattle, Washington 98104
UEKG
of As F
0
om
O \ 49442 E
O �F�SLNNA ENG�21t21t9
No.
_SS
75 LF 12" DI
WATER LINE NOTES
QFIRE HYDRANT ASSEMBLY PER CITY OF RENTON STD. PLAN 310.1.
QCAP AND ABANDON EXISTING WATER MAIN.
A3
VERTICAL CROSS (MJxFL) POLY PIG STATION FOR WATERMAIN CLEANING PER
CITY OF RENTON STD PLAN 300.6.
ANOT USED.
A5
INSTALL 1" WATER SERVICE PER CDR STANDARD PLAN 320.1 AND 1" PRESSURE
REDUCING VALVE IN METER BOX PER COR STD PLAN NO. 340.5. RECONNECT
TO EXISTING PRIVATE WATER SERVICE LINE.
A. 2" BLOW —OFF PERMANENT ASSEMBLY PER CITY OF RENTON STD PLAN 340.1.
ACONNECT TO 12" EXISTING WATER MAIN PER CITY OF RENTON STD PLAN 300.5.
RELOCATE EXISTING 4" POST INDICATOR VALVE AND 1' DCVA AND RESET
8 EXISTING HYDRANT. CITY OF RENTON TO RELOCATE 1.5" DOMESTIC WATER METER
AND 1" LANDSCAPE METER.
QPROTECT EXISTING HYDRANT.
INSTALL 1" WATER SERVICE PER CDR STANDARD PLAN 320.1. RECONNECT TO
10 EXISTING PRIVATE WATER SERVICE LINE.
1-1/2" WATER SERVICE, 1-1/2" DCVA FOR IRRIGATION PER CITY OF RENTON
11 STD PLAN 320.2 AND 1-1/2" PRESSURE REDUCING VALVE IN METER BOX PER
CDR STD PLAN NO. 340.5 SEE SHEETS IR1—IR6 FOR IRRIGATION PLANS AND
CONNECTION DETAILS.
INSTALL
12 SHACKLEVALVE DEAD—MAN
BLOCK BENDS AND HYDRANTTE TO BLOC
CSTID DR ON 12" WATER.
A SHACKLE RECORD D RAWI N G
TEMPORARY 12" PLUG (MJ) W/THRUST BLOCK ON NEW 12" WATER. FINAL THIS RECORD DRAWING WAS PREPARED USING
13 CONNECTION TO BE MADE AFTER COMPLETION OF 12" WATER LINE IN NE 10TH INFORMATION PROVIDED TO CONSULTANT AND
STREET. CONTAINS ONLY THE LEVEL OF DETAIL AS PROVIDED.
INSTALL DEAD —MAN BLOCK PER CDR STD PLAN NO. 330.4 ON EXISTING 12" THE INFORMATION WAS NOT INDEPENDENTLY FIELD
14 WATER AND SHACKLE EXISTING NORTH 12" VALVE TO BLOCK BEFORE VERIFIED. THE CONSULTANT DOES NOT WARRANT OR
INSTALLATION OF NEW 12" WATER MAIN IN NE 10TH STREET AND BEFORE FINAL GUARANTEE THE ACCURACY OR COMPLETENESS OF THE
CONNECTION TO EXISTING 12' WATER MAIN. INFORMATION SHOWN.
6V JAIN 1 "=20
— CITY OF
nxn'
�J. BEAN �� DATUM RENTON
D. DEKOEKKOEK Planning/Building/Public Works Dept.
REVISION BY DATE APPR PA P DE aoLoT sc.���aan"sr
KEY MAP
LEGEND
W
WATER LINE PIPE
SS
SANITARY SEWER PIPE
SD
STORM DRAIN PIPE
— — W — —
WATER LINE PIPE (EXISTING)
— —SS— —
SANITARY SEWER PIPE (EXISTING)
— —SD— —
STORM DRAIN PIPE (EXISTING)
PIPE REMOVAL
Qi
WATER LINE NOTE
❑�
CATCH BASIN TYPE 1
®
CATCH BASIN TYPE 2 WITH GRATE
�O
CATCH BASIN TYPE 2 WITH SOLID LID
BIORETENTION FILTRATION UNIT
®
SANITARY SEWER MANHOLE
FIRE HYDRANT
N
GATE VALVE
I--[ T-1
BEND
134
TEE
►
THRUST BLOCK
❑
REDUCER
CAP
PLUG
DEAD —MAN BLOCK
",40
SCALE
20 0 20 40
FEET
CITY OF RENTON
SUNSET LANE NE IMPROVEMENTS
WATER PLAN
�B0/2016
WP1
s.Uff °l
51 9,