Loading...
HomeMy WebLinkAboutW-387506w z z U EL.I W z a a __J I— LL (n z (n GENERAL NOTES 1. THE CONTRACTOR SHALL POTHOLE ALL UTILITY CROSSINGS PRIOR TO STARTING CONSTRUCTION OF THE PIPE RUN. 2. ALL MJ FITTINGS AND VALVES SHALL HAVE MEGALUGS (OR APPROVED EQUAL) RETAINER GLANDS IN ADDITION TO CONCRETE BLOCKING. CALL 2 BUSINESS DAYS BEFORE YOU DIG Per'tee't 1 800 4 2 4- 5 5 5 5 206-436-0515 1 1-800-615-9! UTILITIES UNDERGROUND LOCATION CENTER 505 5th Avenue S, Suite 300 Seattle, Washington 98104 OEKG of As F 0 om O \ 49442 E O �F�SNNA LENG�21t21t9 WATER LINE NOTES QFIRE HYDRANT ASSEMBLY PER CITY OF RENTON STD. PLAN 310.1 QCAP AND ABANDON EXISTING WATER MAIN. A3 VERTICAL CROSS (MJxFL) POLY PIG STATION FOR WATERMAIN CLEANING PER CITY OF RENTON STD PLAN 300.6. QNOT USED. A5 INSTALL 1" WATER SERVICE PER COR STANDARD PLAN 320.1 AND 1" PRESSURE REDUCING VALVE IN METER BOX PER CDR STD PLAN NO. 340.5. RECONNECT TO EXISTING PRIVATE WATER SERVICE LINE. Q2" BLOW —OFF PERMANENT ASSEMBLY PER CITY OF RENTON STD PLAN 340.1. QCONNECT TO 12" EXISTING WATER MAIN PER CITY OF RENTON STD PLAN 300.5. RELOCATE EXISTING 4" POST INDICATOR VALVE AND 1' DCVA AND RESET 8 EXISTING HYDRANT. CITY OF RENTON TO RELOCATE 1.5" DOMESTIC WATER METER AND 1" LANDSCAPE METER. APROTECT EXISTING HYDRANT. INSTALL 1" WATER SERVICE PER COR STANDARD PLAN 320.1. RECONNECT TO 10 EXISTING PRIVATE WATER SERVICE LINE. 1-1/2" WATER SERVICE, 1-1/2" DCVA FOR IRRIGATION PER CITY OF RENTON 11 STD PLAN 320.2 AND 1-1/2" PRESSURE REDUCING VALVE IN METER BOX PER CDR STD PLAN NO. 340.5 SEE SHEETS IR7—IR6 FOR IRRIGATION PLANS AND CONNECTION DETAILS. INSTALL DEAD —MAN BLOCK PER CDR STD PLAN NO. 330.4 ON 12" WATER. 12 SHACKLE 12" VALVE, BENDS AND HYDRANT TEE TO BLOCK. TEMPORARY 12" PLUG (MJ) W/THRUST BLOCK ON NEW 12" WATER. FINAL 13 CONNECTION TO BE MADE AFTER COMPLETION OF 12" WATER LINE IN NE 10TH STREET. 14 INSTALL DEAD —MAN BLOCK PER CDR STD PLAN NO. 330.4 ON EXISTING 12" WATER AND SHACKLE EXISTING NORTH 12" VALVE TO BLOCK BEFORE INSTALLATION OF NEW 12" WATER MAIN IN NE 10TH STREET AND BEFORE FINAL CONNECTION TO EXISTING 12' WATER MAIN. mmxeoA JAIN 1. BEAN nccxmb. DEKOEKKOEK N0. REVISION BY DATE APPR ""A P DE BOLDT 1 "=20' RECORD DRAWING THIS RECORD DRAWING WAS PREPARED USING INFORMATION PROVIDED TO CONSULTANT AND CONTAINS ONLY THE LEVEL OF DETAIL AS PROVIDED. THE INFORMATION WAS NOT INDEPENDENTLY FIELD VERIFIED. THE CONSULTANT DOES NOT WARRANT OR GUARANE THE ACCURACY OR COMPLETENESS OF THE INFORMATETION SHOWN. IF �x="Mww�3,ss„ CITY OF RENTON DATUM Planning/Building/Public Works Dept. KEY MAP LEGEND W WATER LINE PIPE SS SANITARY SEWER PIPE SD STORM DRAIN PIPE — — W — — WATER LINE PIPE (EXISTING) — —SS— — SANITARY SEWER PIPE (EXISTING) — —SD— — STORM DRAIN PIPE (EXISTING) PIPE REMOVAL QWATER LINE NOTE ❑� CATCH BASIN TYPE 1 ® CATCH BASIN TYPE 2 WITH GRATE �O CATCH BASIN TYPE 2 WITH SOLID LID BIORETENTION FILTRATION UNIT ® SANITARY SEWER MANHOLE FIRE HYDRANT N GATE VALVE I--[ T-I BEND 134 TEE ► THRUST BLOCK ❑ REDUCER CAP PLUG DEAD —MAN BLOCK SCALE 20 0 20 40 FEET CITY OF RENTON SUNSET LANE NE IMPROVEMENTS WATER PLAN 4/2016 WP6 56�9