HomeMy WebLinkAboutT-387506NW 1/ SEC 9, T 23 N, R 5 E, W.M.
w
z
U
0
a
W
Z
w
Z
a
J
W
0
Z
MATCH LINE STA 26+00,
SEE DWG IL5
MATCH LINE STA 24+75,
SEE DWG IL4
GENERAL NOTES
'N
J
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH 2O16 WSDOT STANDARD 8. JUNCTION BOXES SHALL BE KEPT OUT OF THE SIDEWALK UNLESS
PLANS & SPECIFICATIONS AND THE LATEST AMENDMENTS, APWA STANDARDS, APPROVED BY THE ENGINEER OR INSTRUCTED ON THE PLANS. JUNCTION
THE CITY DEVELOPMENTAL GUIDELINES, EXCEPT AS MODIFIED BY CONTRACT BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID RESISTANT LIDS PER
PLANS AND SPECIAL PROVISIONS. SPECIAL PROVISIONS. JUNCTION BOXES IN PLANTER STRIP SHALL HAVE A LEGEND
CONCRETE PAD PER CDR STD PLAN 120. ALL JUNCTION BOXES SHALL
2. UTILITY LOCATION (1-800-424-5555) PRIOR TO CONSTRUCTION SHALL BE HAVE LOCKING LIDS PER COR STD PLAN 119.
THE RESPONSIBILITY OF THE CONTRACTOR. CONFLICTS SHALL BE BROUGHT LUMINAIRE -SEE SCHEDULE ON IL6
TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION. 9. ALL TYPE 1 AND 2 JUNCTION BOXES SHALL BE PER WSDOT STD PLAN
J-40.10-03.
3. THE CONTRACTOR SHALL COORDINATE ELECTRICAL SERVICE CONNECTION WITH
THE POWER COMPANY. CONTACT PUGET SOUND ENERGY REPRESENTATIVE
SHERI CLARKE AT (425) 456-2701 PRIOR TO INSTALLATION OF METER BASE.
SEE SECTION 8-20.3 OF THE SPECIAL PROVISIONS.
4. CONTACT TRANSPORTATION MAINTENANCE ASSISTANT MANAGER ERIC CUTSHALL
® 425-430-7423 FOR POLE NUMBERS TO BE INSTALLED PER CDR STD
PLAN 121.
5. ALL ILLUMINATION CONDUIT SHALL BE RIGID PVC SCHEDULE 80, SEE SPECIAL
PROVISIONS SECTION 8-20.3(5)B. ALL INTERCONNECT (FIBER OPTIC) CONDUIT
SHALL BE RIGID PVC SCHEDULE 80 WITH FLEXIBLE FABRIC INNER DUCT
INSTALLED PER SPECIFICATIONS.
6. ALL CONDUIT CONTAINING COPPER CONDUCTORS SHALL INCLUDE 1-#8
GROUND WIRE (MIN. SIZE UNLESS SPECIFIED IN WIRE SCHEDULE). ALL
CONDUIT SHALL CONTAIN A PULL -LINE TAPE LABELED "CITY OF RENTON"
UNLESS PRIVATELY OWNED BY PSE, CENTURYLINK, AND COMCAST.
7. ALL CONDUIT CONTAINING FIBER AND FUTURE FIBER CONDUIT SHALL BE
INSTALLED WITH DETECTABLE UNDERGROUND WARNING TAPE PER WSDOT STD
SPECIFICATION SECTION 8-20.3(5)A7.
CALL 2 BUSINESS DAYS BEFORE YOU DIG Per'tee't
1 800 4 2 4- 5 5 5 5 206-436-0515 1 1-800-615-9!
UTILITIES UNDERGROUND LOCATION CENTER 505 5th Avenue S, Suite 300
Seattle, Washington 98104
10. ILLUMINATION CONDUIT AND JUNCTION BOX LOCATIONS ARE SCHEMATIC AND
SHOWN FOR REFERENCE TO EASE WITH INSTALLATION UNLESS IT IS PART
OF THE JOINT UTILITY TRENCH. FINAL LOCATIONS SHALL BE DETERMINED
BY THE CONTRACTOR AND APPROVED BY THE ENGINEER IN THE FIELD.
11. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE
THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL). IF
NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL
INSTALL ADDITIONAL JUNCTION BOXES AS REQUIRED.
12. SEE SECTION 1-07.17 OF THE SPECIAL PROVISIONS FOR SPECIAL
FRANCHISE UTILITY COORDINATION REQUIREMENTS.
13. SEE THE APPENDIX D OF THE SPECIAL PROVISIONS FOR CONSTRUCTION
PLANS AND REQUIREMENTS, AND SUPPLEMENTAL INFORMATION FOR THE
FOLLOWING FRANCHISE UTILITIES: PSE, COMCAST, AND CENTURYLINK.
14. JOINT UTILITY TRENCH CONDUIT DIAGRAM AND SECTIONS WERE DEVELOPED
BY COMPILING ALL THE INFORMATION PROVIDED BY THE FRANCHISE UTILITIES
IN APPENDIX D OF THE SPECIAL PROVISIONS. TRENCH SECTIONS HAVE BEEN
PROVIDED TO ASSIST THE CONTRACTOR ON THE BIDDING AND BUILDING OF
THE PROJECT. CONTRACTOR SHALL COORDINATE WITH ALL FRANCHISE
UTILITIES DURING CONSTRUCTION AND RECEIVE FINAL APPROVAL FROM EACH
INDIVIDUAL FRANCHISE UTILITY PRIOR TO BACKFILLING THE TRENCH.
SCALE
20 0 20 40
FEET
0EKp
�,�
~
um�xo
EsG nE
3
DID
1o/29/1a
DID M. MACIAS
49442 2
\ "Is EE G\�Z�t21tp 1
AllNO.
MAM
JJH
REVISION BY
1/17/17
9/27/16
DATE
DID J. BEAN
DID HP P. DE BOLDT
APPR A M MACIAs
m
JUNCTION BOX TYPE 1
0
JUNCTION BOX TYPE 2
9:1
JUNCTION BOX TYPE 8
®
SERVICE CABINET
25-TA
COR VAULT
PSE
PSE VAULT
conlcnsr
COMCAST VAULT
CLINK
CENTURYLINK VAULT
TELE
1
TELECOMMUNICATION VAULT
-------
CONDUIT
- JOINT UTILITY TRENCH - SEE IL11
QCONDUIT WIRE NOTE - SEE SCHEDULE ON IL6
O CONSTRUCTION NOTE
RECORD DRAWING
THIS RECORD DRAWING WAS PREPARED USING
INFORMATION PROVIDED TO CONSULTANT AND
CONTAINS ONLY THE LEVEL OF DETAIL AS PROVIDED.
THE INFORMATION WAS NOT INDEPENDENTLY FIELD
VERIFIED. THE CONSULTANT DOES NOT WARRANT OR
GUARANTEE THE ACCURACY OR COMPLETENESS OF THE
INFORMATION SHOWN.
=20 °Mww�3'ss" CITY OF
RENTON
�� DATUM
Planning/Building/Public Works Dept
KEY MAP
CONSTRUCTION NOTES
1 CONSTRUCT LUMINAIRE POLE FOUNDATION PER DETAIL ON DRAWING IL9.
FURNISH AND INSTALL ARTERIAL STREET DECORATIVE PEDESTRIAN LUMINAIRE
FIXTURE, POLE, CONDUIT, WIRING AND ALL ASSOCIATED EQUIPMENT PER
DRAWING IL9 AND CDR STD PLAN 117.2 AND 117.3. APPLY DECAL NUMBERING
WITH CDR POLE ID# TO LUMINAIRE POLE PER CDR STD PLAN 121.
QCONSTRUCT LUMINAIRE POLE FOUNDATION PER DETAIL ON DRAWING IL9.
FURNISH AND INSTALL ARTERIAL STREET DECORATIVE ROADWAY LUMINAIRE
FIXTURE, POLE, CONDUIT, WIRING AND ALL ASSOCIATED EQUIPMENT PER
DRAWING IL9 AND COR STD PLAN 117.1 AND 117.3. APPLY DECAL NUMBERING
WITH CDR POLE ID# TO LUMINAIRE POLE PER COR STD PLAN 121.
OCONSTRUCT CONCRETE FOUNDATION PER COR STD PLAN 126.1 AND FURNISH
AND INSTALL 120/240V ELECTRICAL SERVICE CABINET PER CDR STD PLAN
122.1 AND 123. RUN 1-2"SPARE CONDUIT TO ADJACENT JUNCTION BOX.
CONNECT ALL FIELD WIRING. CONTRACTOR WILL COORDINATE POWER
CONNECTION WITH UTILITY COMPANY AND COMPLETE ALL WORK REQUIRED
BETWEEN SERVICE CABINET AND CONNECTION POINT. TRANSPORTATION
MAINTENANCE ASSISTANT MANAGER ERIC CUTSHALL SHALL BE PRESENT WHEN
SYSTEM IS TURN ON AND STREET LIGHTING INSPECTION IS SIGNED OFF.
OEXTEND JOINT UTILITY TRENCH 5-FT BEHIND BACK OF CURB, STUB OUT AND
CAP PSE CONDUITS.
OINSTALL COMMUNICATION VAULT. SEE TABLE ON DRAWING IL11 FOR VAULT
SCHEDULE AND SPECIAL PROVISIONS FOR ADDITIONAL FRANCHISE UTILITY
CONSTRUCTION REQUIREMENTS.
OINSTALL POWER VAULT. SEE TABLE ON DRAWING IL11 FOR VAULT TYPE AND
SPECIAL PROVISIONS FOR ADDITIONAL PSE CONSTRUCTION REQUIREMENTS.
OINSTALL SMALL CABLE VAULT PER WSDOT STD PLAN J-90.21-00 FOR CITY OF
RENTON INTERCONNECT SYSTEM.
OROUTE CONDUIT INTO EXISTING VAULT FROM JOINT UTILITY TRENCH. SEE
DRAWINGS IL11 FOR CONDUIT DIAGRAM AND DRAWINGS IL14-IL15 FOR JOINT
UTILITY TRENCH DETAILS.
OINTERCEPT EXISTING CONDUIT CARRYING CONDUCTORS FOR PEDESTRIAN
LUMINAIRE LOCATED ON NE 10TH ST (STA 26+25 RT) AND ROUTE INTO
PROPOSED TYPE 2 JUNCTION BOX, SPLICE CONDUCTORS TO CIRCUIT D -
PEDESTRIAN ILLUMINATION. INSTALL PEDESTRIAN LUMINAIRE.
10 INSTALL VIDEO DETECTION CAMERA AND MOUNT ON SIGNAL MAST ARM PER
MANUFACTURER'S RECOMMENDATION. ROUTE WIRE BACK TO SIGNAL CONTROLLER
USING EXISTING CONDUIT. SEE SPECIAL PROVISIONS.
11 INSTALL VIDEO DETECTION PROCESSOR IN SIGNAL CABINET PER
MANUFACTURER'S RECOMMENDATION. SEE SPECIAL PROVISIONS.
12 SEE DETAIL 2 ON DRAWING IL10 FOR FOUNDATION PLACEMENT WITHIN
SIDEWALK.
13 INSTALL BUILDING STUB OUT PER DETAIL 4 ON DRAWING IL10. SEE SPECIAL
PROVISIONS FOR FRANCHISE UTILITY CONSTRUCTION REQUIREMENTS.
14 RELOCATE EXISTING PRIVATE LUMINAIRE ONTO NEW LUMINAIRE FOUNDATION PER
DETAIL 2 ON DRAWING IL10. REMOVE EXISTING ASSOCIATED ELECTRICAL
EQUIPMENT NO LONGER NEEDED. GRIND DOWN EXISTING FOUNDATION 2' BELOW
PROPOSED GRADE. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL
PROVISIONS. CONTRACTOR IS RESPONSIBLE FOR LOCATING POWER SOURCE AND
ROUTING INTO NEW FOUNDATION PRIOR TO REMOVING EXISTING LUMINAIRE.
FINAL LOCATION TO BE CONFIRMED DURING CONSTRUCTION.
15 ROUTE INTERCONNECT CONDUIT INTO EXISTING CDR JUNCTION BOX AND SPLICE
FIBER PER SPECIAL PROVISIONS.
16 ROUTE CONDUITS TO BASE OF UTILITY POLE. SEE SPECIAL PROVISIONS FOR
FRANCHIS UTILITY P S AND CONTINUATION OF WORK. 1
17 ROUTE CENTURYLINK/TELECOMMUNCATION CONDUIT TO BASE OF EXISTING
PEDESTAL. SEE SPECIAL PROVISIONS FOR FRANCHISE UTILITY PLANS AND
CONTINUATIO OF WORK.
18 INT CEPT EXISTING FRANCHISE UTILITY CONDUIT. UTILITY AND CONDUIT SIZE
SHOWN ON CONSTRUCTION NOTE. SEE JOINT UTILITY TRENCH CONDUIT DIAGRAM
AN SE N, S IAL OVI NS R D IL O_ ON.
19 INSTALL THREE 4-INCH AND ONE 6-INCH CONDUITS BELOW DRIVEWAY.
PROTECT AND MAINTAIN EXISTING CONDUITS. SEE DETAIL 3 ON DRAWING IL10
OR ADDITIONAL INFORM
20 RO E CDR INTERCONNECT CONDUIT TO NEW TYPE 2 JUNCTION BOX INSTALLED
AT BASE OF UTILITY POLE. CONTINUE CDR CONDUIT UP UTILITY POLE VIA
STEEL CONDUIT RISER PER WSDOT STANDARD PLAN J-15.10-01.
21 INSTALL TYPE 2 JUNCTION BOX FOR PARK NETWOR ING SYSTEM. 2
CITY OF RENTON �E0/2016
SUNSET LANE NE
e
-'NiILLUMINATION AND JOINT UTILITY TRENCH PLAN a