Loading...
HomeMy WebLinkAboutT-387508/ NW % SEC 9, T 23 N, R 5 E, W.M. \ 16 / / / COMCAST-CV#3 13 5 S2 3 3 S1 PSE-PV#3 13 6 \°m L 1��/ ss _.._ 3' 20 1 3 g \ \ Q TELECOM-CV#2AS 13 5 / SS V c W �/-_ z z W w Z 5y ss pJ G 3 C 10 Y"' y LLI V' �. �G 10 23 w g 21 COMCAST-CV#2 PSE-PV#2 13 ^.. GENERAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH 2O16 WSDOT STANDARD PLANS & SPECIFICATIONS AND THE LATEST AMENDMENTS, APWA STANDARDS, THE CITY DEVELOPMENTAL GUIDELINES, EXCEPT AS MODIFIED BY CONTRACT PLANS AND SPECIAL PROVISIONS. 2. UTILITY LOCATION (1-800-424-5555) PRIOR TO CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION. 3. THE CONTRACTOR SHALL COORDINATE ELECTRICAL SERVICE CONNECTION WITH THE POWER COMPANY. CONTACT PUGET SOUND ENERGY REPRESENTATIVE SHERI CLARKE AT (425) 456-2701 PRIOR TO INSTALLATION OF METER BASE. SEE SECTION 8-20.3 OF THE SPECIAL PROVISIONS. 4. CONTACT TRANSPORTATION MAINTENANCE ASSISTANT MANAGER ERIC CUTSHALL ® 425-430-7423 FOR POLE NUMBERS TO BE INSTALLED PER CDR STD PLAN 121. 5. ALL ILLUMINATION CONDUIT SHALL BE RIGID PVC SCHEDULE 80, SEE SPECIAL PROVISIONS SECTION 8-20.3(5)B. ALL INTERCONNECT (FIBER OPTIC) CONDUIT SHALL BE RIGID PVC SCHEDULE 80 WITH FLEXIBLE FABRIC INNER DUCT INSTALLED PER SPECIFICATIONS. 6. ALL CONDUIT CONTAINING COPPER CONDUCTORS SHALL INCLUDE 1-#8 GROUND WIRE (MIN. SIZE UNLESS SPECIFIED IN WIRE SCHEDULE). ALL CONDUIT SHALL CONTAIN A PULL -LINE TAPE LABELED "CITY OF RENTON" UNLESS PRIVATELY OWNED BY PSE, CENTURYLINK, AND COMCAST. 7. ALL CONDUIT CONTAINING FIBER AND FUTURE FIBER CONDUIT SHALL BE INSTALLED WITH DETECTABLE UNDERGROUND WARNING TAPE PER WSDOT STD SPECIFICATION SECTION 8-20.3(5)A7. 21t INSTALL CONDUIT FROM SERVICE "S1" TO TELECOM-CV#4 5 13 COMCAST-CV#4 � 1 P9 C, 21 I 17 17 23 2 \ o P10 1 \ 22 13 PSE-PV#4 \ P8 I P11 1 20 � `� 17 I FUTURE SIDEWALK AND LUMINAIRE t7 ` s � 1 24 LOCATIONS UPDATED PER SUNSET \� \ `A NEIGHBORHOOD PARK BID SET OF, I PLANS. \ 7 I 22 I I J P7 23 II _ B. JUNCTION BOXES SHALL BE KEPT OUT OF THE SIDEWALK UNLESS APPROVED BY THE ENGINEER OR INSTRUCTED ON THE PLANS. JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID RESISTANT LIDS PER SPECIAL PROVISIONS. JUNCTION BOXES IN PLANTER STRIP SHALL HAVE A CONCRETE PAD PER CDR STD PLAN 120. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PER CDR STD PLAN 119. 9. ALL TYPE 1 AND 2 JUNCTION BOXES SHALL BE PER WSDOT STD PLAN J-40.10-03. 10. ILLUMINATION CONDUIT AND JUNCTION BOX LOCATIONS ARE SCHEMATIC AND SHOWN FOR REFERENCE TO EASE WITH INSTALLATION UNLESS IT IS PART OF THE JOINT UTILITY TRENCH. FINAL LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED BY THE ENGINEER IN THE FIELD. 11. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL). IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL INSTALL ADDITIONAL JUNCTION BOXES AS REQUIRED. 12. SEE SECTION 1-07.17 OF THE SPECIAL PROVISIONS FOR SPECIAL FRANCHISE UTILITY COORDINATION REQUIREMENTS. 13. SEE THE APPENDIX D OF THE SPECIAL PROVISIONS FOR CONSTRUCTION PLANS AND REQUIREMENTS, AND SUPPLEMENTAL INFORMATION FOR THE FOLLOWING FRANCHISE UTILITIES: PSE, COMCAST, AND CENTURYLINK. 14. JOINT UTILITY TRENCH CONDUIT DIAGRAM AND SECTIONS WERE DEVELOPED BY COMPILING ALL THE INFORMATION PROVIDED BY THE FRANCHISE UTILITIES IN APPENDIX D OF THE SPECIAL PROVISIONS. TRENCH SECTIONS HAVE BEEN PROVIDED TO ASSIST THE CONTRACTOR ON THE BIDDING AND BUILDING OF THE PROJECT. CONTRACTOR SHALL COORDINATE WITH ALL FRANCHISE UTILITIES DURING CONSTRUCTION AND RECEIVE FINAL APPROVAL FROM EACH INDIVIDUAL FRANCHISE UTILITY PRIOR TO BACKFILLING THE TRENCH. LEGEND LUMINAIRE - SEE SCHEDULE ON IL6 m JUNCTION BOX TYPE 1 JUNCTION BOX TYPE 2 W] JUNCTION BOX TYPE 8 ® SERVICE CABINET 25-TA COR VAULT PSE PSE VAULT 0 COMCAST VAULT 4:]TELEC.MMUNICATION VAULT ------- CONDUIT JOINT UTILITY TRENCH - SEE IL71 QCONDUIT WIRE NOTE - SEE SCHEDULE ON IL6 O CONSTRUCTION NOTE 0EKp H� Perteet CALL 2 BUSINESS DAYS BEFORE YOU DIG o z 4 DID 10 29/1a DID m, 3 MAM 4/26/17 DID M. MAcl.as 1 800 4 2 4- 5 5 5 5 206-436-0515 1 1-800-615-990C 49442 2 MAM 1/17/17 DID "J. BEAN UTILITIES UNDERGROUND LOCATION CENTER 505 5th Avenue S, Suite 300 \ �Fss/ONqL EENG�� t21tp t JJH a/z7/7e DID Pq mP DE BOLDT Seattle, Washington 98104 Q� NO. REVISION BY DATE APPR A M Mncins 1 "=20' SCALE 20 0 20 40 FEET RECORD DRAWING THIS RECORD DRAWING WAS PREPARED USING INFORMATION PROVIDED TO CONSULTANT AND CONTAINS ONLY THE LEVEL OF DETAIL AS PROVIDED. THE INFORMATION WAS NOT INDEPENDENTLY FIELD VERIFIED. THE CONSULTANT DOES NOT WARRANT OR GUARANTEE THE ACCURACY OR COMPLETENESS OF THE INFORMATION SHOWN. oMw:w�"'s CITY OF RENTON DATUM Planning/Building/Public Works Dept KEY MAP CONSTRUCTION NOTES 1 CONSTRUCT LUMINAIRE POLE FOUNDATION PER DETAIL ON DRAWING IL9. FURNISH AND INSTALL ARTERIAL STREET DECORATIVE PEDESTRIAN LUMINAIRE FIXTURE, POLE, CONDUIT, WIRING AND ALL ASSOCIATED EQUIPMENT PER DRAWING IL9 AND CDR STD PLAN 117.2 AND 117.3. APPLY DECAL NUMBERING WITH CDR POLE ID# TO LUMINAIRE POLE PER CDR STD PLAN 121. CONSTRUCT LUMINAIRE POLE FOUNDATION PER DETAIL ON DRAWING IL9. 2 FURNISH AND INSTALL ARTERIAL STREET DECORATIVE ROADWAY LUMINAIRE FIXTURE, POLE, CONDUIT, WIRING AND ALL ASSOCIATED EQUIPMENT PER DRAWING IL9 AND CDR STD PLAN 117.1 AND 117.3. APPLY DECAL NUMBERING WITH CDR POLE ID# TO LUMINAIRE POLE PER CDR STD PLAN 121. OCONSTRUCT CONCRETE FOUNDATION PER CDR STD PLAN 126.1 AND FURNISH AND INSTALL 120/240V ELECTRICAL SERVICE CABINET PER CDR STD PLAN 122.1 AND 123. RUN 1-2"SPARE CONDUIT TO ADJACENT JUNCTION BOX. CONNECT ALL FIELD WIRING. CONTRACTOR WILL COORDINATE POWER CONNECTION WITH UTILITY COMPANY AND COMPLETE ALL WORK REQUIRED BETWEEN SERVICE CABINET AND CONNECTION POINT. TRANSPORTATION MAINTENANCE ASSISTANT MANAGER ERIC CUTSHALL SHALL BE PRESENT WHEN SYSTEM IS TURN ON AND STREET LIGHTING INSPECTION IS SIGNED OFF. OEXTEND JOINT UTILITY TRENCH 5-FT BEHIND BACK OF CURB, STUB OUT AND CAP PSE CONDUITS. OINSTALL COMMUNICATION VAULT. SEE TABLE ON DRAWING IL11 FOR VAULT SCHEDULE AND SPECIAL PROVISIONS FOR ADDITIONAL FRANCHISE UTILITY CONSTRUCTION REQUIREMENTS. OINSTALL POWER VAULT. SEE TABLE ON DRAWING IL11 FOR VAULT TYPE AND SPECIAL PROVISIONS FOR ADDITIONAL PSE CONSTRUCTION REQUIREMENTS. OINSTALL SMALL CABLE VAULT PER WSDOT STD PLAN J-90.21-00 FOR CITY OF RENTON INTERCONNECT SYSTEM. OROUTE CONDUIT INTO EXISTING VAULT FROM JOINT UTILITY TRENCH. SEE DRAWINGS IL11 FOR CONDUIT DIAGRAM AND DRAWINGS IL14-IL15 FOR JOINT UTILITY TRENCH DETAILS. OINTERCEPT EXISTING CONDUIT CARRYING CONDUCTORS FOR PEDESTRIAN LUMINAIRE LOCATED ON NE 10TH ST (STA 26+25 RT) AND ROUTE INTO PROPOSED TYPE 2 JUNCTION BOX, SPLICE CONDUCTORS TO CIRCUIT D - PEDESTRIAN ILLUMINATION. INSTALL PEDESTRIAN LUMINAIRE. 10 INSTALL VIDEO DETECTION CAMERA AND MOUNT ON SIGNAL MAST ARM PER MANUFACTURER'S RECOMMENDATION. ROUTE WIRE BACK TO SIGNAL CONTROLLER USING EXISTING CONDUIT. SEE SPECIAL PROVISIONS. 11 INSTALL VIDEO DETECTION PROCESSOR IN SIGNAL CABINET PER MANUFACTURER'S RECOMMENDATION. SEE SPECIAL PROVISIONS. 12 SEE DETAIL 2 ON DRAWING IL10 FOR FOUNDATION PLACEMENT WITHIN SIDEWALK. 13 INSTALL BUILDING STUB OUT PER DETAIL 4 ON DRAWING IL10. SEE SPECIAL PROVISIONS FOR FRANCHISE UTILITY CONSTRUCTION REQUIREMENTS. 14 RELOCATE EXISTING PRIVATE LUMINAIRE ONTO NEW LUMINAIRE FOUNDATION PER DETAIL 2 ON DRAWING IL10. REMOVE EXISTING ASSOCIATED ELECTRICAL EQUIPMENT NO LONGER NEEDED. GRIND DOWN EXISTING FOUNDATION 2' BELOW PROPOSED GRADE. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS. CONTRACTOR IS RESPONSIBLE FOR LOCATING POWER SOURCE AND ROUTING INTO NEW FOUNDATION PRIOR TO REMOVING EXISTING LUMINAIRE. FINAL LOCATION TO BE CONFIRMED DURING CONSTRUCTION. 15 ROUTE INTERCONNECT CONDUIT INTO EXISTING CDR JUNCTION BOX AND SPLICE FIBER PER SPECIAL PROVISIONS. 16 ROUTE CONDUITS TO BASE OF UTILITY POLE. SEE SPECIAL PROVISIONS FOR FRANCHISE UTILITY PLANS AND CONTINUATION OF WORK. 17 ROUTE CENTURYLINK/TELECOMMUNCATION CONDUIT TO BASE OF EXISTING PEDESTAL. SEE SPECIAL PROVISIONS FOR FRANCHISE UTILITY PLANS AND CONTINUATION OF WORK. 18 IN CEPT EXISTING FRANCHISE UTILITY CONDUIT. UTILITY AND CONDUIT SIZE SHOWN ON CONSTRUCTION NOTE. SEE JOINT UTILITY TRENCH CONDUIT DIAGRAM AN SE N, S IAL OVI NS R D IL RM ON. 19 INSTALL THREE 4-INCH AND ONE 6-INCH CONDUITS BELOW DRIVEWAY. PROTECT AND MAINTAIN EXISTING CONDUITS. SEE DETAIL 3 ON DRAWING IL10 OR ADDITION L INF RMAT 20 RO E COR INTERCONNECT CONDUIT TO NEW TYPE 2 JUNCTION BOX INSTALLED AT BASE OF UTILITY POLE. CONTINUE CDR CONDUIT UP UTILITY POLE VIA STEEL CONDUIT RISER PER WSDOT STANDARD PLAN J-15.10-01. 21 INSTALL TYPE 2 JUNCTION BOX FOR PARK NETWOR ING SYSTEM. 2 CITY OF RENTON 1 DE0/2016 SUNSET LANE NE B 10 ILLUMINATION AND JOINT UTILITY TRENCH PLAN 66