HomeMy WebLinkAboutT-387515w
z
U
POLE
4'-0"
(LUMINAIRE ARM LENGTH)
2" TANGENT
7.5' R 13.5" CLAMP —ON TO
z LUMINAIRE (TYR)
In
3.5" OD HOLE
W
z (LUMINAIRE ARM LENGTH)
LU 16' R 22"
z
a
J
I-— 4" HOLE
LU
� I
z
(LUMINAIRE ARM LENGTH)
N 1 60' R 46"
4" OD HOLE
LUMINAIRE ARM DETAILS
NTS
T" — 1 A" DIAM. WIREWAY
O1 941, 1
BRACKET SIDE VIEW DETAILS
NTS
ROUND CAP
ALUMINUM SHROUD
(BY MANUFACTURER)
MANUFACTURER SHALL 3" SHROUD
WELD SHROUD ALL HEIGHT
THE WAY AROUND
LUMINAIRE CLAMP
FULLY COVERS RISE CLAMP —ON TO
LUMINAIRE
LUMINAIRE ARM
LUMINAIRE CONDUCTORS
DECORATIVE LUMINAIRE
LUMINAIRE ARM MOUNTING
BRACKET DETAILS
NTS
Y
02'-
000
0000
0000
0000
0000
0000
0000
0000
00 0
0R0
0000
DETECTABLE WARNING
SURFACE PER PLANS
5' v v v
3 SIDEWALK
SEE SECTION G—G
ON SHEET IL74�
YIL10
LUMINAIRE #3 FOUNDATION
DETAIL 1
LUMINAIRE #3 FOUNDATION
NTS 2
EXISTING
DRIVEWAY
POLE PER LUMINAIRE SCHEDULE BACK OF
SIDEWALK
DETECTABLE WARNING
SURFACE PER PLANS BANK RUN GRAVEL
FOR TRENCH
ROADWAY PER PLANS 5' BACKFILL
RELOCATE LUMINAIRE TO
STA 25+38 (35.50' LT)
PARKING LOT
FINISHED GRADE
(4) 1 %36%4" ELL
ANCHOR BOLTS
TYPE 3 FOUNDATION,
SEE DRAWING IL9 FOR DETAILS
0EKp
CALL 2 BUSINESS DAYS BEFORE YOU DIG Per'tee't
1 800 4 2 4- 5 5 5 5 206-436-0515 1 1-800-615-990 49442 0
UTILITIES UNDERGROUND LOCATION CENTER 505 5th Avenue S, Suite 300 \ �Fss/ONq� EENG���t211p
Seattle, Washington 98104 2
/ SIDEWALK SLOPE PER PLANS
~ IIII IIII IIII BACKFILL FOR SAND
DRAINS
CONTRACTOR TO -
IIIIII II�III IIIIII INSTALL 6—INCH
CONDUIT FOR FUTURE
USE
BY PSE.
I II
I I
TYPE 2 FOUNDATION,
SEE DRAWING IL9 FOR DETAILS
SECTION Y-Y
NTS
-BOLT CIRCLE: * CONTRACTOR SHALL VERIFY BOLT
*BASE PLATE: CIRCLE AND BASE PLATE
DIMENSIONS PRIOR TO
CONSTRUCTION OF FOUNDATION.
II II
II II
II II
II II
II II
II II
II II
II I
II �I
II
II
II
II
II
II
II
II
II
�
II
II
II
II
0
I
DETAIL 2
PRIVATE LUMINAIRE FOUNDATION
NTS
2 MAM 1/17/17 DID
1 MAM T1/2/18 DID
NO. REVISION BY DATE APPR
Z IL1
Z —
SEE SECTION G—G
�ON SHEET IL74
DETAIL 3
JOINT UTILITY TRENCH UNDER LIBRARY DRIVEWAY
6'-4
- ^ MIN: " AAIM
NTS
LEGEND
UTILITY UTILITY
C = COMCAST
.I- OWNER CL = CENTURYLINK
C P = PSE (POWER)
° C4 G = PSE (GAS)
1 I = CITY (ILLUMINATION)
36" MIN } F = CITY (FIBER)
EXISTING CONDUIT J SIZE (INCHES)
TWO 2—INCH AND ONE 4—INCH
CONDUIT TO REMAIN EMPTY.
' SLIDE 2—INCH ILLUMINATION CONDUIT
3" THROUGH EX. 4—INCH CONDUIT.
4 (TYP)
4" .... ..i ;:.:.
-� CONDUIT, SEE LEGEND
2- SPACING BETWEEN FOR UTILITY OWNER
CONDUITS (TYP) ONE 4—INCH CONDUIT TO REMAIN EMPTY. AND SIZE
4—INCH GAS TO BE INSTALLED BY PSE BY SLIDING THROUGH 6—INCH CONDUIT INSTALLED BY
CONTRACTOR. CONTRACTOR SHALL COORDINATE INSTALLATION WITH PSE. SEE SPECIAL
PROVISIONS SECTION 1-07.17.
SECTION Z—Z
NTS
STA 1 1 +78.50 TO STA 12+08.50
STUB OUT AND CAP ONE 4—INCH CONDUIT
5—FT BEHIND BACK OF SIDEWALK PER PLANS
BACK OF
JOINTILU'ILITY TRENCH
SIDEWALK PER
PLANS
PER
SIDEWALK 11 1
i 11 II
r--7u �i
--o �- -7 —--
1 u u
II
3, u u
11 liT11 II I
�1
MAINTAIN A 3—FT PERIMETER CLEAR ZONE
AROUND THE VAULTS. NO STRUCTURES (POLES,
D
HYDRANTS, CATCH BASINS) AND LANDSCAPING
2' D 2' D
— 3 C
✓/I (TREES, SHRUBS) ARE ALLOWED INSIDE THIS
AREA. SIDEWALK AND CURB ARE PERMITTED.
PLANTER
STRIP
T
VAULT PER
*PLANS
3 VAULT PER
VAULT
PER
*PLANS PLANS* I CONC CURB
`CEM
—
RECORD DRAWING
THIS RECORD DRAWING WAS PREPARED USING
*SEE DRAWING IL1 1 FOR VAULT SCHEDULE
INFORMATION PROVIDED TO CONSULTANT AND
CONTAINS ONLY THE LEVEL OF DETAIL AS PROVIDED.
DETAIL 4
THE INFORMATION WAS NOT INDEPENDENTLY FIELD
VERIFIED. THE CONSULTANT DOES NOT WARRANT OR
TYPICAL VAULT
GROUP LAYOUT D ETAI L
GUARANTEE THE ACCURACY OR COMPLETENESS OF THE
INFORMATION SHOWN.
NTS
NONE
° -
DATUM
. CITY OF
' RENTON
CITY OF RENTON
SUNSET LANE NE
�rE 4/2016
61cN M MACIAS
"""" ,BEAN
* IL1O
P. DE BOLDT
Planning/Building/Public Works Dept.
ILLUMINATION DETAILS
PA
M. MAMAS"""`
73 ° 94