Loading...
HomeMy WebLinkAboutR-387555w z U 0 a IRRIGATION PARTS LEGEND SYMBOL DESCRIPTION MANUFACTURER/NOTES RAIN BIRD 1812 SAM PRS SERIES HEADS AND MPR NOZZLES © 8F (1.05 GPM 0 30 PSI) RAIN BIRD 8 SERIES 8H (0.52 GPM 0 30 PSI) MPR PLASTIC NOZZLE 8-10' RADIUS AT 30 PSI 8T (0.35 GPM 0 30 PSI) 1 8Q (0.26 GPM 0 30 PSI) 12F (2.60 GPM 0 30 PSI) RAIN BIRD 12 SERIES W z 12 12TQ (1.95 GPM ®30 PSI) MPR PLASTIC NOZZLE 12' RADIUS AT 30 PSI LLI 1y 12TT (1.74 GPM 0 30 PSI) Q12 12H (1.30 GPM 0 30 PSI) J �* 12T (0.87 GPM 0 30 PSI) L1n C 12 12Q (0.65 GPM 0 30 PSI) Z (n 15 15F (3.70 GPM 0 30 PSI) RAIN BIRD 15 SERIES 15 15TQ (2.78 GPM ®30 PSI) MPR PLASTIC NOZZLE 15' RADIUS AT 30 PSI 15 15TT (2.48 GPM 0 30 PSI) 15 15H (1.85 GPM 0 30 PSI) 15T (1.23 GPM 0 30 PSI) 15 15Q (0.92 GPM 0 30 PSI) 15VANQ (0.93 GPM 0 30 PSI) RAIN BIRD VAN SERIES 12VANQ (0.65 GPM 0 30 PSI) MPR PLASTIC NOZZLE VARIABLE ARC RADIUS 8VANQ (0.72 GPM 0 30 PSI) ® 15SST (1.21 gpm 0 30 psi) RAIN BIRD STRIP SERIES 4'x 30' side strip pattern at 30 PSI MPR PLASTIC NOZZLE SPRAY PATTERN AT 30 PSI iSEST (0.61 gpm ®30 psi) 4'x 15' end strip pattern at 30 PSI SYMBOL DESCRIPTION .❑ METER ® CONTROLLER (LOCATION PER OWNER) pd DCVA ELECTRONIC REMOTE CONTROL VALVE n QUICK COULPER - - - - - - - - MAINLINE LATERIAL LINE - ----- -- SLEEVE FINISHED COMPACTED SCH 80 PVC BACKFlLL, TYP. - UNION, TYP. SHUT-OFF VALVE ° (STOP &WASTE) FLOW FROM SERVICE METER, SEE CIVIL DRAWINGS. CAP END - UD, TYP. SIZE TO ACCOMMODATE IRRIGATION EQUIP. PROVIDE EXTENSIONS AS REQUIRED. SCH 80 PVC NIPPLE, MIN. 3" LENGTH, TYP. I PVC. FEM. 12" CLEAR ADAPTER. MANUFACTURER/NOTES 1-1/2" INSTALLED PER CITY OF RENTON STD. PLAN 320.2 SENTINEL COMPUTERIZED CONTROLLER, GENERAL TO PROVIDE POWER SOURCE IN CONDUIT PROVIDE PEDESTAL ENCLOSURE 1-1/2" FEBCO 805Y PER APPROVAL. REVIEW AND INSPECTION PROVIDED IN BID. RAIN BIRD PEB-PRS SERIES RAINBIRD 44K W/ LOCKING CAP 1-1/2" SIZE - SCH. 40 PVC BELL PIPE. LOOP MAIN CLASS 200 PVC BELL PIPE. 1" MAX. 3/4" MIN. DROP SIZE OF BRANCH LATERAL PER PLAN. OFF -SHOOTS OF LATERAL TO LESS THAN 4 HEADS FROM 1" BRANCH SHALL BE 3/4". 4" MIN. SCH. 40 PVC OR TWICE SIZE OF INSERT PIPE �I QUICK COUPLER SEE DETAIL MAIN LINE, SEE IRRIG. LEGEND )p°o PERE. DRAIN LINE. J \ SUPPORT AS READ. J TIE TO STORM DRAIN DOl18EE CHECK VALVE NOTE, OR DAYLIGHT. 1° WASHED DRAIN AS PER WATER DISTRICT SEE IRRIGATION LEGEND ROCK COMPACTED INSTALLATION DETAILS FOR EQUIPMENT SIZES AND SUB GRADE AND INSPECTION. SEE MANUFACTURER. IRRIGATION LEGEND. DVCA CONNECTION ASSEMBLY SPRAY NOZZLE, SEE IRRIGATION PLAN LEGEND. FINISH GRADE 4" OR 12" POP-UP RISER SEE IRIGATION LEGEND. 10" VALVE BOX _- IIIII FINISH GRADEII11.1- -�� I- III III II IRi- POP-UP BODY, SEE Will COMPACTED BACKFlLL, TYP. BRASS QUICK CONSTRICTING HOSE CLAMP, TYP. IRRIGATION LEGEND DEPTH AS COUPLING VALVE 3/4" x 1/2" MALE BARBED EL SPECIFIED 1" SCH 40 PVC STREET ELL 1" x 8" SCH 80 PVC NIPPLES SCH 40 PVC TEE 1/2" FLEXIBLE POLLY PIPE RISER, MIN. 18' LENGTH. MAX. PVC MAINLINE, SEE LEGEND 3/4" SCH. 40 STREET 36" LENGTH. EL 'MARLEX'. 1/2" MALE BARBED EL. 1" z 8" SCH 80 PVC NIPPLES CLASS 200 PVC LATERAL LINE, 3/4" MIN. SCH. 40 PVC THREADED TEE 24" LENGTH #5 RE -BAR STAKE QUICK COUPLER VALVE (QCV) DETAIL POP-IP SPRAY HEAD DETAIL N.T.S. N.T.S. Pe rte et STA E DE CALL 2 BUSINESS DAYS BEFORE YOU DIG �nn� w xINGTDN v REGISTERED UNDSCAPE ARCHRECT 1 800 4 2 4- 5 5 5 5 206-436-0515 1 1-800-615-990 505 5th Avenue S, Suite 300 cm nc DD Naaise ER UTILITIES UNDERGROUND LOCATION CENTER No. Seattle, Washington 98104 REVISION N.T.S. VALVE BOX, 12"x18" MIN. PRESSURE REGULATOR MODULE, IF SPECIFIED. COMPACTED BACKFlLL, TYP.� FINISH GRADE - PVC 99 ELL: AUTO. CONTROL VALVE SIZE PER ZONE VALVE SCHED. SEE PLAN. `°(�O PVC LATERAL TRACE WIRE (2) PVC FEMALE ADAPTERS PVC PIPE SIZE (2) SCH 80 PVC NIPPLES, MIN. 8" CONTROL WIRES SAME AS MAINUNE LENGTH. SAME DIA. OF VALVE, TYP. BUNDELED & PVC TEE OR ELL. 1-CU/FT. WASHED 1" GRAVEL SUMP PLACE IN PVC CONDUIT WHEN PVC MAIN UNE WIRES ARE NOT WITH MAINLINE. AUTOMATIC CONTROL VALVE DETAIL N.T.S. esmxeJ WALKER way. J. BEAN xmP DE BOLDT BY DATE APPR ""R j. WALKER NONE VALVE SCHEDULE VALVE# SIZE GPM 1 1" 20.25 2 1" 21.34 3 1" 26.11 4 1" 17.17 5 1" 19.78 6 1" 18.09 7 1" 25.24 8 1" 24.49 9 1" 33.83 10 OPEN NA 11 OPEN NA 12 OPEN NA IRRIGATION GENERAL NOTES 1. GENERAL CONTRACTOR AND LANDSCAPE CONTRACTOR TO COORDINATE: A. PROTECTION OF SITE, INCLUDING: LOCATING ALL EXISTING AND NEW UNDERGROUND UTILITY LINES PRIOR TO ANY CONSTRUCTION, SAVING AND PROTECTING EXISTING TREES DESIGNATED TO REMAIN, REPAIRING ANY DAMAGE DONE TO CURBING, SIDEWALKS, FENCES, AND ANY OTHER DAMAGE CAUSED AS A RESULT OF THIS CONTRACT. B. INSTALLATION OF 110V ELECTRICAL SERVICE FROM ELECTRICAL SOURCE TO AUTOMATIC CONTROLLER, INCLUDING WIRE HOOK-UP INTO MOUNTED CONTROLLER. IRRIGATION CONTRACTOR WILL MOUNT CONTROLLER PER DESIGN AND COORDINATE WITH GENERAL CONTRACTOR. C. INSTALLATION OF IRRIGATION/SERVICE METER AND STUB TO IRRIGATION POINTS OF CONNECTION PURSUANT TO CITY OF RENTON REQUIREMENTS. D. PROVISION OF STANDARD THREADED STUB -OUT WITH THREADED CAP ON DISCHARGE SIDE OF METERS. STUB -OUT TO BE INSTALLED APPROXIMATELY 18 INCHES BELOW FINISHED GRADE. E. VERIFICATION OF STATIC WATER PRESSURE AT POINT -OF -CONNECTION (P.O.C.) CONTRACTOR SHALL NOTIFY ENGINEER OF STATIC PRESSURE AND ADVISE IF SYSTEM PRV IS NECESSARY F.INSTALLATION OF SLEEVING TO BE COORDINATED WITH GENERAL CONTRACTOR PRIOR TO PAVEMENT. 2. CONTROLLER IS TO BE PROVIDED BY CONTRACTOR WITH POWER AND OTHER WIRING. 3. SYSTEM HAS BEEN DESIGNED FOR MAX. 30 GPM AT 35 PSI AT THE FURTHEST NOZZLE. VERIFY ADEQUATE STATIC PRESSURE SETTING FOR OPTIMAL SYSTEM PERFORMANCE. PROVIDE SYSTEM PRV IF NECESSARY. 4. PRIOR TO INITIATION OF WORK CONTRACTOR SHALL VERIFY ALL WORK TO BE DONE PER LOCAL CODE AND PER MANUFACTURER'S PRODUCT SPECIFICATIONS. 5. SET VALVE BOXES FLUSH WITH FINISHED GRADES IN PLANTING AREAS. 6. PIPES FOR LATERAL LINES SHALL BE SIZED BY CONTRACTOR IN DECREASING DOWNSTREAM ORDER (PER RAIN BIRD DESIGN STANDARDS). 7. LINE POSITIONING IS DIAGRAMMATIC ON PLAN. ADJUST IN FIELD AS NECESSARY FOR ADEQUATE COVERAGE. COORDINATE WITH LANDSCAPE PLANS. VALVES SHALL BE POSITIONED ADJACENT TO CURBS IN SHRUB BEDS FOR SCHEMATIC CLARITY, MAIN AND LATERAL LINE SYMBOLS ON PLANS MAY BE INDICATED AT PAVEMENT, AND ADJACENT AND PARALLEL TO PLANTING AREAS, AND OUTSIDE OF LOT LINES. LINES SHOWN FOR CLARITY IN THESE AREAS ARE TO BE PLACED IN ADJACENT PLANTING AREAS, WITHIN THE PROJECT SITE. 8. PROVIDE OWNER WITH TWO (2) SETS OF AS -BUILT DRAWINGS AND OPERATOR'S MANUAL UPON COMPLETION. INSTRUCT OWNER AS TO PROPER WINTERIZATION OF IRRIGATION SYSTEM (BLOW OUT). 9. FAMILIARIZE FACILITY OPERATOR WITH IRRIGATION SYSTEM FUNCTION, CONTROLLER PROGRAMMING, SYSTEM OPERATION AND MAINTENANCE REQUIREMENTS. 10. ALL CONTROL WIRE SPLICES SHALL BE MADE AT VALVE BOXES. 11. ALL ELECTRICAL EQUIPMENT SHALL BE U.L. TESTED AND APPROVED, AND SHALL BEAR THE U.L. LABEL. 13. PROVIDE MANUAL SHUT-OFF VALVE ALONG BRANCH LATERAL LINE TO EACH ISLAND PLANTER IN 6 INCH DIAMETER VALVE BOX NEAR MAIN CONNECTION. 14. CROSS CONNECTION PROTECTION INSPECTION REQUIRED. BACKFLOW DEVICES SHALL BE TESTED UPON INSTALLATION. A PERSON HOLDING A CURRENT CERTIFICATE AS A BACKFLOW TESTER SHALL PERFORM THE TESTING. THE TEST REPORT SHALL BE SUBMITTED TO THE CITY OF RENTON. CONTRACTOR SHALL INCLUDE TESTING IN THE LUMP SUM BID PRICE OF IRRIGATION SYSTEM COMPLETE. OWNER IS RESPONSIBLE FOR ANNUAL INSPECTIONS AFTER THE INITIAL INSPECTION. 15. CONTRACTOR SHALL PROVIDE SYSTEM WINTERIZATION/SPRING SERVICE WHEN INSTALLATION HAS BEEN COMPLETED WITHIN 90 DAYS OF NOVEMBER 1 FOR WINTERIZATION, OR MAY 15 FOR SPRING SERVICE. SERVICE TO BE PERFORMED AS NEAR AS PRACTICAL TO THE ABOVE DATES, OR AS FREEZE/PRECIPITATION CONDITIONS DETERMINE SERVICE NEED. 16. PROVIDE AUTOMATIC RAIN SHUT -OFFS FOR EACH CONTROLLER. 17. IRRIGATION CONTRACTOR TO PROVIDE A ONE YEAR WARRANTY AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP. 18. IRRIGATION LINES SHALL BE INSPECTED BY THE ENGINEER PRIOR TO BACKFILLING. RECORD DRAWING THIS RECORD DRAWING WAS PREPARED USING INFORMATION PROVIDED TO CONSULTANT AND CONTAINS ONLY THE LEVEL OF DETAIL AS PROVIDED. THE INFORMATION WAS NOT INDEPENDENTLY FIELD VERIFIED. THE CONSULTANT DOES NOT WARRANT OR GUARANTEE THE ACCURACY OR COMPLETENESS OF THE INFORMATION SHOWN. IF RI=oMww�3,ss„ CITY OF RENTON DATUM Planning/Building/Public Works Dept. CITY OF RENTON SUNSET LANE NE IMPROVEMENTS IRRIGATION LEGEND, NOTES, AND DETAILS 4/2016 IR6 91 �?