HomeMy WebLinkAboutPRE014-000195_Lim Short Plat_3921 Meadow Ave N_2-lot SHPL_R-8PREAPPLICATION MEETING FOR
MAX DRIVE Short Plat
PID 619720-0060
PRE 14-000294
CITY OF RENTON
Department of Community & Economic Development
Planning Division
March 20, 2014
Contact Information:
Planner: Kris Sorensen, 425.430.6593
Public Works Plan Reviewer: Jan Illian, 425.430.7216
Fire Prevention Reviewer: Corey Thomas, 425.430.7024
Building Department Reviewer: Craig Burnell, 425.430.7290
Please retain this packet throughout the course of your project as a reference. Consider
giving copies of it to any engineers, architects, and contractors who work on the
project. You will need to submit a copy of this packet when you apply for land use
and/or environmental permits.
Pre-screening: When you have the project application ready for submittal, call and
schedule an appointment with the project manager to have it pre-screened before
making all of the required copies.
The pre-application meeting is informal and non-binding. The comments provided on
the proposal are based on the codes and policies in effect at the time of review. The
applicant is cautioned that the development regulations are regularly amended and the
proposal will be formally reviewed under the regulations in effect at the time of project
submittal. The information contained in this summary is subject to modification and/or
concurrence by official decision-makers (e.g., Hearing Examiner, Planning Director,
Development Services Director, Department of Community & Economic Development
Administrator, Public Works Administrator and City Council).
c:\users\jcisneros\appdata\local\temp\pre014-000195_lim short plat_3921 meadow ave n_2-lot shpl_r-
8_8053125\pre014-000195_lim short plat_3921 meadow ave n_2-lot shpl_r-8.doc
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE: February 27, 2014
TO: Pre-application File No. 14-000195
FROM: Kris Sorensen, Associate Planner
SUBJECT: Lim Short Plat
General: We have completed a preliminary review of the pre-application for the above-
referenced development proposal. The following comments on development and
permitting issues are based on the pre-application submittals made to the City of
Renton by the applicant and the codes in effect on the date of review . The applicant is
cautioned that information contained in this summary may be subject to modification
and/or concurrence by official decision-makers (e.g., Hearing Examiner, Community &
Economic Development Administrator, Public Works Administrator, Planning Director,
Development Services Director, and City Council). Review comments may also need to
be revised based on site planning and other design changes required by City staff or
made by the applicant. The applicant is encouraged to review all applicable sections of
the Renton Municipal Code. The Development Regulations are available for purchase
for $100.00 plus tax, from the Finance Division on the first floor of City Hall or online at
www.rentonwa.gov
Project Proposal: The subject property is located at the address 3921 Meadow Ave N
(PID 3342700530). The project site is a stem lot (or “flag lot”) in configuration and is
generally flat. The property is zoned Residential – 8 dwelling units per net acre and is
18,600 square feet (0.42 acre) in size. The applicant is proposing to subdivide the
property into two lots. Proposed lot sizes would be approximately 13,348 square feet
and approximately 5,190 square feet with a private shared driveway along the southerly
side of the lots. The site currently has an existing single family home where the larger
lot, Lot B, is proposed that would be kept with the proposed Lot A for building a new
single family home. Lot A has accessory structures that would need to be demolished
prior to short plat recording. The applicant is proposing vehicular access to the two
properties from a private driveway connected to Meadow Ave N.
Current Use: The site currently has an existing single family home where Lot B would be
located in the eastern portion of the property.
Zoning/Density Requirements: The subject property is zoned Residential-8 dwelling
units per acre (R-8). The minimum density in the R-8 zone is 4 dwelling units per net
acre and the maximum density is 8.0 du/ac. Density rounding allows a density of 8.49
du/ac to still meet the maximum density allowance. Private access easements, critical
Lim Short Plat, PRE14-000195
Page 2 of 4
February 27, 2014
c:\users\jcisneros\appdata\local\temp\pre014-000195_lim short plat_3921 meadow ave n_2-lot shpl_r-
8_8053125\pre014-000195_lim short plat_3921 meadow ave n_2-lot shpl_r-8.doc
areas and public right-of-way dedications would be deducted from the total area to
determine net density. A right-of-way dedication of 6.5 feet for this project would be
required along Meadow Ave N, see Plan Review comments for more details. For this
application, the private access easement for the shared driveway and right-of-way
dedication required along Meadow Ave N would be deducted. A rough density
worksheet calculation provides a density of 6.5 du/ac which meets the allowed
density for the R-8 zone. A Density Worksheet would be required at the time of formal
short plat application.
Development Standards: The project would be subject to RMC 4-2-110A, “Development
Standards for Single Family Zoning Designations” effective at the time of complete
application. A copy of these standards are included.
Minimum Lot Size, Width and Depth – The minimum lot size permitted in Zone R-8 is
5,000 square feet for parcels being subdivided that are 43,560 square feet (1 acre) or
less. Minimum lot width is 50 feet for interior lots; minimum lot depth is 65 feet. It
appears that there is adequate room on the project site to comply with the lot size,
width, and depth standards.
Building Standards – The R-8 zone allows a maximum building coverage of 35% of the lot
area or 2,500 square feet, whichever is greater for lots over 5,000 square feet in size.
The maximum impervious coverage in the R-8 zone is 75%. Building height is restricted
to 30 feet. Detached accessory structures must remain below a he ight of 15 feet and
one-story. Accessory structures are also included in building lot coverage calculations.
Compliance with building standards for the new single family home will be determined
at the time of building permit review for any new structure . For the existing home
staying, data and dimensions will be needed at time of short plat application.
Setbacks – Setbacks are the minimum required distance between the building footprint
and the property line. The required setbacks in the R-8 zone are:
Front yard: 15 feet for the primary structure.
Rear yard: 20 feet.
Side yards: 5-feet, except 15-feet for side yards along a street or private street.
For a side yard along a shared private driveway easement, an interior sideyard
setback is required of 5-feet.
Yards (ie front, rear and sides) would need to be shown on the site plan. Setback
would be verified at the time of building permit review for the new lot. The existing
building footprint and required setbacks on proposed Lot B would need to be
indicated on the submitted site plan.
Residential Design and Open Space Standards: The Residential Design and Open Space
Standards contained in RMC 4-2-115 would be applicable to any new residential
structures. A handout indicating the applicable guidelines and standards is enclosed.
Lim Short Plat, PRE14-000195
Page 3 of 4
February 27, 2014
c:\users\jcisneros\appdata\local\temp\pre014-000195_lim short plat_3921 meadow ave n_2-lot shpl_r-
8_8053125\pre014-000195_lim short plat_3921 meadow ave n_2-lot shpl_r-8.doc
Access/Parking: The applicant has indicated that access would be taken for both
proposed lots via a shared driveway from Meadow Ave N. The proposed access would
meet the allowance for a shared private driveway. See Plan Review comments for more
details and Fire comments for width and paving requirements. Two off street parking
spaces are required for each proposed lot. Driveways cannot be greater than 15%
slope.
Landscaping: Except for critical areas, all portions of a development area not covered
by structures, required parking, access, circulation or service areas, must be landscaped
with native, drought-resistant, vegetative cover. Development standards require that all
pervious areas within the property boundaries be landscaped. The minimum on-site
landscape width required along street frontages is 10 feet. In addition, two trees are
required in the front yard setback area of each lot when there are no street trees within
the street right-of-way as referenced in the landscape regulations (RMC 4-4-070F).
Please refer to landscape regulations (RMC 4-4-070) for further general and specific
landscape requirements. A conceptual landscape plan would be required at the time of
formal Short Plat application. A detailed landscape plan would be required at the time
of Building permit application for Lot A.
Significant Tree Retention: Significant trees (greater than 6-inch caliper) are potentially
proposed to be removed; therefore, a tree inventory and a tree retention plan along
with a tree retention worksheet must be provided with the formal land use application.
The tree retention plan must show preservation of at least 30 percent of significant
trees, and indicate how proposed building footprints would be sited to accommodate
preservation of significant trees that would be retained. If the trees cannot be retained,
replacement may be allowed with minimum 2 inch caliper trees at a ratio of six to one.
Critical Areas: A small portion of the northwest corner of the site contains a moderate
landslide hazard area.
Environmental Review: Except when located in sensitive areas or lands covered by
water, short plats of four or fewer lots are Categorically exempt from Environmental
(SEPA) Review.
Permit Requirements: The proposal would require approval of an administrative short
plat. The administrative short plat request would be reviewed within an estimated time
frame of six to eight weeks. The fee for a short plat application is $1,442.00 ($1,400.00
plus 3% Technology Surcharge Fee). Detailed information regarding the land use
application submittal is provided in the attached handouts.
Lim Short Plat, PRE14-000195
Page 4 of 4
February 27, 2014
c:\users\jcisneros\appdata\local\temp\pre014-000195_lim short plat_3921 meadow ave n_2-lot shpl_r-
8_8053125\pre014-000195_lim short plat_3921 meadow ave n_2-lot shpl_r-8.doc
Fees: In addition to the applicable building and construction fees, impact fees would be
required. Such fees would apply to all projects and would be calculated at the time of
building permit application and payable prior to building permit issuance. The fees for
2014 are as follows (credit will be given for the existing home):
Transportation Impact Fee: $1,430.72 per new single-family house;
Park Impact Fee: $963.01 per new single-family house; and
Fire Impact Fee: $479.28 per new single-family house.
Renton School District Impact Fee: $5,455.00
Note: When the formal application materials are complete, the applicant is strongly
encouraged to have one copy of the application materials pre-screened at the 6th
floor front counter prior to submitting the complete application package. Please call
Kris Sorensen, Associate Planner at 425-430-6593 for an appointment.
Expiration: Upon approval, the short plat is valid for two years with a possible one year
extension.